Voice identification is being increasingly adopted in various domains, including security infrastructures, intelligent home systems, and personalised digital assistants. Notably, it harbours significant promise in transforming healthcare, especially in electronic health record detecting and speech impairment monitoring such as aphasia. Current strategies such as acoustic models based on deep learning, voice bio‐metrics, and spectrogram analysis, have been identified with several drawbacks including vulnerability to altered voices, susceptibility to ambient noise, and the necessity for significant computational power. In response to these issues, the authors introduce a ground‐breaking method of voice identification using Ultra‐Wideband (UWB) technology. This method capitalises on the micro‐Doppler shifts associated with movements of the laryngeal prominence. The distinctive nature of these bio‐metric traits related to speech production provides superior resistance against common pitfalls of voice identification. The proposed model leverages the high‐resolution characteristics of UWB to register tiny variations in laryngeal movements produced during speech, thus forming a distinct voice profile for each speaker. Through rigorous testing, the proposed system demonstrated significant progress in voice identification, achieving close to 90% accuracy in controlled experimental settings. This breakthrough indicates that UWB‐enabled voice identification could have a profound effect on medical applications, providing potential improvements in diagnosing, monitoring, possibly treating speech disorders, and thereby shaping a future of enhanced and secured healthcare services.
Objective: This study aimed to assess how accurately mobile wearable devices could be used to monitor vital signs continuously in clinical settings by comparing their measurements with those from traditional bedside monitors. Methods: Data collected from Mindray's mWear wearable device were compared against measurements from the BeneVision N15 traditional bedside monitoring system. A total of 208 paired datasets, including blood pressure, oxygen saturation, heart rate, and respiratory rate, were collected from 16 healthy volunteers in a clinical setting. Bland-Altman analysis was applied to assess agreement between the two devices. Results: The analysis showed that 94.2% of the data variance points for oxygen saturation, diastolic blood pressure, and pulse rate fell within the limits of agreement. For systolic blood pressure, 92.3% of the data variance points were within limits, while 94.7% of the heart rate and respiratory rate data points were also within agreement limits. Conclusion: There was a strong agreement between the wearable mWear device and the traditional bedside patient monitoring system. This study supports the accuracy and reliability of wearable devices for continuous vital signs monitoring. These results encourage the wider use and ongoing improvement of wearable technology in clinical practice.
People counting and occupancy monitoring play a vital role in applications such as intelligent building management, safety control, and resource optimization in future smart cities. Conventional camera and infrared-based methods often suffer from privacy risks, lighting dependency, and limited robustness in complex indoor environments. In this paper, we present a 60 GHz millimeter-wave (mmWave) radar-based occupancy monitoring system that enables accurate and privacy-preserving people counting. The proposed system leverages echo signals processed through Doppler and range spectrogram and analyzed by an enhanced ResNet-50 deep learning model to classify motion states and count individuals. Experimental results collected in a typical indoor environment demonstrate that the system achieves 95.45% accuracy across 6 classes of movements and 98.86% accuracy for people counting (0–3 persons). The method also shows strong adaptability under limited data and robustness to Gaussian blur interference, providing an efficient and reliable solution for intelligent indoor occupancy monitoring.