This paper reports on the position and force control of pneumatic artificial muscles reinforced by straight glass fibers. This type of artificial muscle has a greater contraction ratio and power and a longer lifetime than conventional McKibben types. However, these muscles are highly non-linear; hence, it is difficult to use them in a mechanical system. Furthermore, this actuator has a high compliance characteristic. Though this characteristic is useful for human interactions, the position and force of this actuator cannot be easily controlled. In this paper, a mathematical model of this type of artificial muscle is proposed, and the relationship between design parameters and control specifications is realized. In addition, the position and force based on the mathematical model are determined and applied to artificial muscle linearization.
Robots have become an integral part of human life, and the relationship between human and robots has grown closer. Thus, it is desirable for robots to have characteristics similar to those of humans. In this context, we paid attention to an artificial muscle actuator, and studied and developed straight-fiber-type artificial muscles derived from McKibben-type muscles, which have an excellent contraction rate and force characteristics. We developed a manipulator with 6-d.o.f. using artificial muscles as actuators and considered its position control. However, artificial muscle manipulators are susceptible to load torque because they do not use any gears and are flexible. Joint stiffness must increase because accurate position control of the artificial muscle is difficult. Stiffness control must respond quickly to achieve coordination with human activity; however, conventional stiffness control by torque-based methods depends on the position control response. Therefore, position and stiffness control need to be independent of each other. In this study, we propose a new method of joint stiffness control, which adds estimated stiffness to the torque-based method. In addition, we performed experiments examining the load response to steady-state and instantaneous loads.
Currently, serious accidents are caused frequently by the aging of sewer pipes. Therefore, to inspect sewer pipes, we developed a peristaltic crawling robot that reproduces the locomotion of an earthworm. This robot can drive for more than 100m, and it can be used for the maintenance of sewer pipes (100A pipes). However, the speed of the robot is low. There are two causes. First, the units of the previous robot have steps of artificial muscle fastening. These steps increase the diameter of the artificial muscles. A smaller diameter of the artificial muscles is advantageous for the speed of the robot inside the pipes. Second, the previous robot has slow air response. In this study, we used large-sized solenoid valves to overcome this drawback.
In this paper, the prototype of the assistive suit for lower limbs was developed. The prototype was based on an assist method with joint stiffness and antagonized angle control. The assist method comprises a system consisting of a pneumatic artificial muscle and a pull spring, which changes the joint stiffness and the antagonized angle to correspond to the movement phase and aims at coordinated motion assistance with the wearer. First, the characteristics of the developed prototype were tested. It was confirmed that the measured value of the prototype followed the target value in the relationship between torque and angle. In addition, there was hysteresis in the measured value, but it did not affect the assist. Next, the evaluation of standing-up and gait assist by measuring electromyography (EMG) of the knee extensor muscle was conducted using the prototype. In all subjects, a decrease in EMG due to the assist was confirmed. In one subject, the maximum decrease rate at the peak of the EMG was about 50% for standing-up motion and about 75% for gait motion. From the results of these assist evaluations, the effectiveness of the assist method based on the joint stiffness and antagonistic angle control using the prototype was confirmed.
The number of large intestine cancer patients has been increasing steadily. An endoscope can be used to diagnose as well as to treat the diseased part of the intestine. A large intestine endoscope is used mainly to examine cancer of the large intestine. However, many doctors have problems handling an endoscope. To resolve this issue, there is demand for a robotic application to assist in inserting the endoscope and straightening the slack from the intestine. We propose a robot that imitates the peristaltic crawling of an earthworm and uses an artificial rubber muscle as an actuator. By attaching the robot to an existing endoscope, it will be possible to move the endoscope forward and pull up the intestine simultaneously, while retaining the functions of the existing endoscope. In this paper, we test the forward and pulling movements of a sliding-air-tube robot in a large intestine of model to evaluate its performance. From these experiments, the robot equipped with the endoscope of 11 mm in the diameter can be moved at the speed that satisfies it. Further, air-emit function is added to this robot and its performance in the large intestine of a dead swine is evaluated. Result of accomplishing experiment by using imitation of endoscope of 8 mm, this robot showed that it had the ability to move the endoscope.