This paper proposes the electronic heart sound sensor, based on the piezoresistive principle and MEMS (Micro-Electro-Mechanical System) technology. Firstly, according to the characteristics of heart sound detection, the double-beam-block microstructure has been proposed, and the theoretical analysis and finite element method (FEM) simulation have been carried out. Combined with the natural frequency response of the heart sound (20~600 Hz), its structure sizes have been determined. Secondly, the processing technology of the microstructure with the stress concentration grooves has been developed. The material and sizes of the package have been determined by the three-layer medium transmission principle. Lastly, the MEMS piezoresistive electronic heart sound sensor has been tested compared with the 3200-type electronic stethoscope from 3M (São Paulo, MN, USA). The test results show that the heart sound waveform tested by the MEMS electronic heart sound sensor are almost the same as that tested by the 3200-type electronic stethoscope. Moreover, its signal-to-noise ratio is significantly higher. Compared with the traditional stethoscope, the MEMS heart sound sensor can provide the first and second heart sounds containing more abundant information about the lesion. Compared with the 3200-type electronic stethoscope from 3M, it has better performance and lower cost.
1 November 2021 in Sensors and Actuators A: Physical
According to the demands of current pipeline detection systems, the above-ground marker (AGM) system based on sound detection principle has been a major development trend in pipeline technology. A novel MEMS acoustic vector sensor for AGM systems which has advantages of high sensitivity, high signal-to-noise ratio (SNR), and good low frequency performance has been put forward. Firstly, it is presented that the frequency of the detected sound signal is concentrated in a lower frequency range, and the sound attenuation is relatively low in soil. Secondly, the MEMS acoustic vector sensor structure and basic principles are introduced. Finally, experimental tests are conducted and the results show that in the range of 0°~90°, when r = 5 m, the proposed MEMS acoustic vector sensor can effectively detect sound signals in soil. The measurement errors of all angles are less than 5°.
To solve the problem that MEMS vector hydrophones are greatly interfered with by the vibration of the platform and flow noise in applications, this paper describes a differential MEMS vector hydrophone that could simultaneously receive acoustic signals and reject acceleration signals. Theoretical and simulation analyses have been carried out. Lastly, a prototype of the differential MEMS vector hydrophone has been created and tested using a standing wave tube and a vibration platform. The results of the test show that this hydrophone has a high sensitivity, Mv = −185 dB (@ 500 Hz, 0 dB reference 1 V/μPa), which is almost the same as the previous MEMS vector hydrophones, and has a low acceleration sensitivity, Mv = −58 dB (0 dB reference 1 V/g), which has decreased by 17 dB compared with the previous MEMS vector hydrophone. The differential MEMS vector hydrophone basically meets the requirements of acoustic vector detection when it is rigidly fixed to a working platform, which lays the foundation for engineering applications of MEMS vector hydrophones.
4 January 2023 in Measurement Science and Technology
The sound source localization (SSL) system based on the microphone array has important applications in audio and video conference, security monitoring and intelligent cockpit. However, the SSL method based on time difference of arrival is susceptible to ambient noise. Therefore, an improved second correlation delay estimation algorithm is proposed in this paper. The pure source signal is obtained by wavelet denoising, and then the time delay is calculated by the second correlation time delay estimation algorithm with the weighting functions of the smoothed coherence transform and the Roth processor. The position of the sound target is calculated from the time delay. Aiming at the moving target, an extended Kalman filter is introduced to track the moving trajectory of the sound source. The static and moving SSL simulations are conducted and the results of the proposed algorithm are compared with those of the single-weighted quadratic correlation (SQC) algorithm and the high-power quadratic correlation algorithm. The static sound source positioning errors of the proposed algorithm under −10 dB SNR are respectively 3.97 m and 5.86 m smaller than those of the HQC algorithm and the SQC algorithm. The moving SSL trajectory based on the proposed algorithm is still closest to the real track under −10 dB SNR. This indicates that the proposed algorithm has high precision and strong robustness for sound source location in the low signal-to-noise ratio (SNR) environment. In the experiment, the proposed algorithm can accurately calculate the direction of arrival (DOA) of static sound source and stably track DOA of moving sound source. This is consistent with the simulation results, which further verifies the effectiveness and practicability of the algorithm. This novel algorithm with high time delay estimation accuracy is of great significance for SSL in low SNR environment.
The application of traditional pressure sensors in health monitoring is limited by their initial rigidity. Flexible pressure sensors have thus received extensive attention owing to their excellent device flexibility. In this paper, we demonstrate a method of constructing flexible pressure sensors by inverting porous skeleton nickel foam based on multi-wall carbon nanotubes (MWCNTs) and polydimethylsiloxane (PDMS). MWCNTs and PDMS were mixed to form a composite conductive film, and the mass fraction of MWCNTs was optimized by evaluating the resistance change rate of the composite film. The optimized value of the mass fraction was 5%, which was used to prepare the flexible pressure sensors. The response, hysteresis, and stability of the sensors were further characterized. Pulse signals of humans were detected through flexible sensors, which can be used to evaluate cardiovascular conditions of the human body. These performance characteristics and the application demonstration show that our flexible pressure sensors have good prospects in human health care.