The MEMS vector hydrophone is a novel acoustic sensor with a “four-beamcilia” structure. Based on the MEMS vector hydrophone with this structure, the paper studies the method of estimated direction of arrival (DOA). According to various research papers, many algorithms can be applied to vector hydrophones. The beam-forming approach and bar graph approach are described in detail. Laboratory tests by means of the a standing-wave tube are performed to validate the theoretical results. Both the theoretical analysis and the results of tests prove that the proposed MEMS vector hydrophone possesses the desired directional function.
With advances in new materials and technologies, there has been increasing research focused on flexible sensors. However, in most flexible pressure sensors made using new materials, it is challenging to achieve high detection sensitivity across a wide pressure range. Although traditional silicon-based sensors have good performance, they are not formable and, because of their rigidity and brittleness, they are not suitable for fitting with soft human skin, which limits their application in wearable devices to collect various signals. Silicon nanomembranes are ultra-thin, flexible materials with excellent piezoresistive properties, and they can be applied in various fields, such as in soft robots and flexible devices. In this study, we developed a flexible pressure sensor based on the use of silicon nanomembranes (with a thickness of only 340 nm) as piezoresistive units, which were transferred onto a flexible polydimethylsiloxane (PDMS) substrate. The flexible pressure sensor operated normally in the range of 0–200 kPa, and the sensitivity of the sensor reached 0.0185 kPa−1 in the low-pressure range of 0–5 kPa. In the high-pressure range of 5–200 kPa, the sensitivity of the sensor was maintained at 0.0023 kPa−1. The proposed sensor exhibited a fast response and excellent long-term stability and could recognize human movements, such as the bending of fingers and wrist joints, while maintaining a stable output. Thus, the developed flexible pressure sensor has promising applications in body monitoring and wearable devices.
10 March 2017 in Journal of Micromechanics and Microengineering
For the purpose of acquiring precise underwater 3D spatial orientation, a ‘fitness-wheel-shaped’ MEMS vector hydrophone (FWVH) is developed, which achieves monitoring of a tri-axial acoustic pressure differential via appropriate constructional design and strain readout. Compared to the previously reported T-structure-combined vector hydrophone (TSVH) which has a nonlinear relationship between output and external force, using the FWVH it is feasible in principle to achieve a tri-axial match, which make it promising in accurate acoustic orientation. A theoretic model for sensitivity is developed, where torque moment is taken into consideration to match the simulation and practical results. Superior to 3D force sensors, bandwidth is taken as the key index for the FWVH and is designed in detail with a compromise of sensitivity. In view of the bandwidth, the parameters are determined for detecting the signal in the range 20–300 Hz. A vibration test demonstrates tri-axial resonance frequencies. Finally, the frequency response curve of the FWVH shows that tri-axial sensitivities are consistent, agreeing with the analysis and simulation results, which reach −174 dB (0 dB referring to 1 V µ Pa −1 ) at 300 Hz.
This paper proposes the electronic heart sound sensor, based on the piezoresistive principle and MEMS (Micro-Electro-Mechanical System) technology. Firstly, according to the characteristics of heart sound detection, the double-beam-block microstructure has been proposed, and the theoretical analysis and finite element method (FEM) simulation have been carried out. Combined with the natural frequency response of the heart sound (20~600 Hz), its structure sizes have been determined. Secondly, the processing technology of the microstructure with the stress concentration grooves has been developed. The material and sizes of the package have been determined by the three-layer medium transmission principle. Lastly, the MEMS piezoresistive electronic heart sound sensor has been tested compared with the 3200-type electronic stethoscope from 3M (São Paulo, MN, USA). The test results show that the heart sound waveform tested by the MEMS electronic heart sound sensor are almost the same as that tested by the 3200-type electronic stethoscope. Moreover, its signal-to-noise ratio is significantly higher. Compared with the traditional stethoscope, the MEMS heart sound sensor can provide the first and second heart sounds containing more abundant information about the lesion. Compared with the 3200-type electronic stethoscope from 3M, it has better performance and lower cost.
The miniaturization of low-frequency marine underwater acoustic detection systems presents new requirements for three-dimensional vector hydrophones. Inspired by fish lateral lines, we have introduced a biomimetic three-dimensional vector hydrophone. It features a microstructure with a monolithically integrated four-beam central block and cilium, capable of detecting underwater acoustic signals from three dimensions. Simulations were conducted to determine the natural frequencies and stress of the hydrophone, helping establish the structural parameters. The arrangement of piezoresistors on the four beams was meticulously designed to minimize inter-axis coupling. The hydrophone chip was fabricated using MEMS technology, followed by comprehensive testing. The hydrophone effectively operates within a detection frequency band of 20-500 Hz. The sensitivities for the three axes are -189 dB@500 Hz, -189.6 dB@500 Hz, and -200.9 dB@500 Hz (0 dB=1 V/μPa), respectively. The concave point depths are 30.4 dB, 29.8 dB, and 26.9 dB, with the voltage density of self-noise at -106 dB at 500 Hz. These results indicate that the biomimetic three-dimensional vector hydrophone holds promising prospects for low-frequency underwater acoustic detection applications.
Since most of the contact conduction type of heart sound sensors don’t take into account the acoustic signal attenuation problem caused by the heart sound signal transmitting to a sensor whose filling materials’ impedance is different to human soft tissue, the signal-to-noise ratio (SNR) of the heart sound sensors is not very well. Human heart is immersed in blood. If the sensor’s core sensitive element can be immersed in fluid, the attenuation of heart sound signal may be decreased greatly. Inspired by the principle of hydroacoustic signal’s detection, this paper proposes the design of heart sound sensor based on the bionic vector hydrophone. Then theoretical analysis and finite element method (FEM) simulation about the sensor have been carried out. Combined sensitivity with resonant frequency, the optimum dimension of the sensor’s structure has been determined. The sensor’s micro-structure has been fabricated by using Micro-Electro-Mechanical System (MEMS) technology and coupling encapsulated by choosing a kind of medical coupling agent as the filling material. Finally, the performance of the proposed sensor is tested. The fact is that the proposed sensor can work well with either healthy people or patients with heart disease. The obtained data clearly show that: the SNR of the proposed heart sound sensor is superior to 3200-type of 3M Littmann 8.2 dB.