Nikita Dobroskok

Mr. Nikita Dobroskok

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019
Verified
Conference Paper
Closed access
AMAnton V. Morozov
Anton V. Morozov
NDNikita Dobroskok
Nikita Dobroskok
VLVictor S. Lavrinovsiy
Victor S. Lavrinovsiy
OMOlga V. Mohova
Olga V. Mohova
The Multi-motor control systems have been increasingly used in many ways for mechanical and electrical drives. In particular, multi-motor drive implementation in high power ship propulsion systems is described in this article. The twin propelled motor which is used as the research subject consists of two mechanically coupled double star induction motors with separate power supply of each stator winding from certain frequency converter. The issues of both voltage synchronization in each pair of frequency converters working in parallel, and load alignment between induction motors are discussed in the article. The modeling results of the proposed interrelated control system are confirmed by the relevant experiments. Finally, the control system offered in this article allows providing sustainable operation of propulsion system in all working conditions.

1 March 2023 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
NDNikita Dobroskok
Nikita Dobroskok
ASAnastasiia Stotckaia
Anastasiia Stotckaia
GBGrigorii V. Belskii
Grigorii V. Belskii
ESElena V. Serykh
Elena V. Serykh
ADAlexey V. Devyatkin
Alexey V. Devyatkin
VBValeriy K. Bulichyov
Valeriy K. Bulichyov
Predictive diagnosis of motor defects can reduce repair and downtime costs of electrical equipment. This paper presents the results of a research on the effectiveness of the defect classification and recognition system based on convolutional neural network to detect defects in a squirrel-cage induction motor based on the stator supply voltage and output phase currents when supplied from an industrial grid of limited power with possible voltage asymmetry and harmonic distortion taken into account. In this work a simulation model, implemented in MATLAB/Simulink, is proposed to investigate unbalanced conditions. The mathematical model has been verified on a physical test bench and then used to create a database of currents from measured asymmetric grid voltages in the presence of defects such as short circuit between turns of one phase, rotor bar breakage, rotor eccentricity and bearing defects. The classification quality of all defects in the neural network was 72%, with the exclusion of intercoil short circuit defect and the merging of different bearing defects, the quality of the model was achieved 91%. A further increase in the quality of the defect recognition system is due to a building up modification of the neural network architecture.

1 January 2017
Verified
Conference Paper
Closed access
AMAnton Morozov
Anton Morozov
NDNikita Dobroskok
Nikita Dobroskok
VLVictor Lavrinovskiy
Victor Lavrinovskiy
OMOlga Mokhova
Olga Mokhova
Electric propulsion systems are widely used in modern shipbuilding due to multiple advantages over systems with mechanical power transmission from the primary engine to the propeller. There is a necessity to use multi-motor drive in order to increase reliability and power in high power propulsion systems. One of the main multi-motor electric drive challenges is load distribution between different electrical machines, which leads to the problem of dynamic and static stability analysis. The aim of this paper is to obtain stability region boundaries of two induction machines coupled by mechanical gear. Approach of stability analysis is proposed. A distinctive feature of this approach is changes of whole system stability region boundaries as compared with single induction machine research.

1 June 2024 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
NDNikita Dobroskok
Nikita Dobroskok
ASAnastasiia Stotckaia
Anastasiia Stotckaia
RMRuslan Migranov
Ruslan Migranov
VLVictor Lavrinovskiy
Victor Lavrinovskiy
YPYuriy Yurievich Perevalov
Yuriy Yurievich Perevalov
NMNazar V. Maslennikov
Nazar V. Maslennikov
A three-phase four-leg bidirectional power converter used as an input stage of an energy storage system using the inductance (L), capacitance (C), and inductance (L) or LCL filter on the grid side is considered. The article provides a variant of the three-phase four-leg bidirectional converter control system implementation based on 3D space vector pulse-width modulation and per-phase voltage control. A brief analysis of the applied control algorithms of the three-phase four-leg bidirectional converter in inverter and rectifier modes is given. A computer model has been built to investigate the operating modes of the converters of the designated class with both balanced and unbalanced load. Studies were carried out by computer modeling methods in order to optimize the parameters of the LCL filter on the grid side with bidirectional energy exchange. Optimal LCL filter parameters and modulation frequencies are determined for the developed converter, providing acceptable quality indicators when operating in bidirectional mode.

26 January 2021
Verified
Conference Paper
Closed access
YKYulia Kim
Yulia Kim
NDNikita Dobroskok
Nikita Dobroskok
ALAndrey N. Lavrinovskiy
Andrey N. Lavrinovskiy
Nowadays, hybrid marine electric power systems containing different types of energy sources or/and energy storages are developing rapidly. That is why it is important to look into the matter of synchronization and distribution of active and reactive load between a conventional synchronous generator (alternating voltage source) and a direct voltage source connected to the ship electric power system via voltage source inverter. These two energy sources have significantly different static and dynamic properties due to the differences in physical nature of voltage and output power control in conventional diesel-synchronous generator and semiconductor power converter. The article focuses on different approaches to the control system synthesis, which allow to provide stable parallel operation of the synchronous generator and the voltage source inverter. MatLab/Simulink model of the simplest algorithm of synchronization and power distribution based on voltage source inverter, synchronous generator and load current and voltage measurements is proposed and investigated in this paper.

1 January 2018
Verified
Conference Paper
Closed access
OMOlga V. Mokhova
Olga V. Mokhova
NDNikita Dobroskok
Nikita Dobroskok
VLVictor S. Lavrinovskiy
Victor S. Lavrinovskiy
AMAnton V. Morozov
Anton V. Morozov
AGAnton V. Galiullin
Anton V. Galiullin
DC generator with independent excitation (DCGIE) with two excitation windings (EW) is considered. It is a part of pulse current supply (PCS) with big power that based on electromechanical energy converters. The output current pulse series of bipolar trapezoidal pulses which amplitudes are decreasing according to exponential law is formed. Under the high requirements to quality of reproducing reference signal the mathematical description of DC generator taking into account nonlinear dependence that expressing the magnetization process in view of hysteresis phenomenon is obtained. The mathematical model of hysteresis proposed by J. Takacs and adapted to generator operating in pulse mode is implemented. As a control system the relay that realized by semi conductive switch devices which are setting the supply of both EW of DCGIE is chosen.