Laura Vandi

Ms. Laura Vandi

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
Alessandro PracucciAlessandro Pracucci
Alessandro Pracucci
LVLaura Vandi
Laura Vandi
FBFrancesco Belletti
Francesco Belletti
AMAmanda Ramos Aragão Melo
Amanda Ramos Aragão Melo
MVMarios Vlachos
Marios Vlachos
DEDavid Seixas Esteves
David Seixas Esteves
This paper presents a study about the integration of Piezoelectric Energy Harvesting Systems (PE-EHSs) into building envelopes for powering Fiber Bragg Grating (FBG) sensors, enabling efficient and low-consumption monitoring with the objective of leveraging structural health monitoring (SHM). The research includes preliminary tests conducted in a real environment to validate the PE-EHS when fully integrated into a ventilated façade, capturing mechanical vibrations generated mainly by wind loads. Based on these activities, the final configuration of PE-EHSs is defined to provide a complete system for façade monitoring. This integrated system includes the piezoelectric generator (PEG), supercapacitor (SC), Power Conditioner Circuit (PCC), Fiber Optic Sensing (FOS) interrogator, and the IoT gateway transmitting measurement data within an Internet of Things (IoT) monitoring platform. This configuration is tailored to address the challenges related to the structural integrity of building envelopes. Results demonstrate a potential for a stand-alone solution in the façade sector but raise issues for certain limitations, requiring further investigation. In particular, the study emphasizes constraints related to the energy production of PE-EHSs for façade integration. It highlights the necessity to carefully consider these limitations within the broader context of their applicability, providing insights for the informed deployment of piezoelectric energy harvesting technology in building envelope monitoring.

31 January 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
Luca MorgantiLuca Morganti
Luca Morganti
LVLaura Vandi
Laura Vandi
PLPaul Julen Astudillo Larraz
Paul Julen Astudillo Larraz
JGJavier Garcia-Jaca
Javier Garcia-Jaca
Arsenio Navarro MuedraArsenio Navarro Muedra
Arsenio Navarro Muedra
Alessandro PracucciAlessandro Pracucci
Alessandro Pracucci
As the construction industry moves toward sustainable building practices, incorporating wood-based materials into building envelope systems has become a priority. This paper investigates the environmental impact of three custom bio-composite Façade System Modules (FSMs) through an Embodied Carbon Assessment (ECA), focused on the Global Warming Potential indicator of life cycle stages from cradle to practical completion (A1–A5). The evaluated FSMs were developed within the Basajaun H2020 project (G.A. 862942), by substituting and combining conventional materials with other bio-composite products to form hybrids from bio-based polymers and wood. A benchmark ECA was conducted, simulating alternative FSMs devised with common practice solutions for the curtain wall façade to facilitate a comprehensive comparison. The life cycle inventory encompassed detailed technical information, fostering the utilization of primary data for accuracy. The study particularly highlights considerations over three technological systems of the modules that incorporate increased use of wood-based components and a novel bio-composite material: the frame profiles, the insulation equipment, and the seal system. Despite the challenges due to the Basajaun FSMs’ weight, the findings reveal that replacing the currently used materials with wood-based materials and bio-composites reduced the embodied emissions, particularly substituting aluminum frame profiles. The insights presented here offer indicators toward circular, environmentally conscious, bio-composed building envelopes, emphasizing the need for continued analysis and refinements as a consequence of increasing the accuracy of the available primary data from the supply chain and concerning end-of-life scenarios.

12 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LVLaura Vandi
Laura Vandi
MCMaria Teresa Calcagni
Maria Teresa Calcagni
FBFrancesco Belletti
Francesco Belletti
GPgiuseppe pandarese
giuseppe pandarese
MMMilena Martarelli
Milena Martarelli
Alessandro PracucciAlessandro Pracucci
Alessandro Pracucci
This paper details the comprehensive activities conducted in a laboratory setting to assess the structural health monitoring (SHM) of prefabricated building envelopes. Integrating sensors into building components like curtain wall facades poses challenges but offers opportunities for monitoring structural health, requiring compliance with regulatory standards. The research investigates the possibility of defining a kit of conventional and multi-parameter sensors integrated within the building envelope to monitor its behavior during the performance test conducted. The kit of sensors also includes Fiber Optic Sensors for effectively monitoring building envelope behavior and structural integrity. In this context, the European project InComEss (H2020-GA862597) aims to define a stand-alone solution for SHM using Piezoelectric Energy Harvesting Systems (PE-EHS) for façade monitoring through FBG/FOS system. After analyzing the main façade structural stress, a series of FBGs, accelerometers, and force washers were integrated within a 1:1 scale façade prototype and tested in a laboratory following the test sequence parameters required by the curtain wall standard EN 13830. The data collected were analyzed with the aim of monitoring the façade behavior before and after the tests. The results show that the façade’s performance passed the assessing test criteria without reporting any damages. In addition, the outcomes demonstrated the effectiveness of the defined kit of multi-parameter sensors for the building envelope’s SHM.

15 April 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LVLaura Vandi
Laura Vandi
Arsenio Navarro MuedraArsenio Navarro Muedra
Arsenio Navarro Muedra
PLPaul Julen Astudillo Larraz
Paul Julen Astudillo Larraz
SESusana López de Aretxaga Escudero
Susana López de Aretxaga Escudero
Alessandro PracucciAlessandro Pracucci
Alessandro Pracucci
This research explores the development and validation activities of a bio-based façade system within the Basajaun H2020 project, focusing on enhancing the utilization of bio-based components within building envelopes to replace conventional solutions with eco-friendly alternatives. This paper reports the methodologies employed to detect requirements and outline the testing protocols undertaken to validate the façade system design devised within the project, focusing on the original façade components as the biocomposite profile. Vision and opaque façade modules are prototyped and tested following curtain wall standards for performance (EN 13830:2015) and acoustic assessments (EN ISO 717-1:2020) to showcase the efficacy of the developed solution. The conducted tests demonstrate the feasibility of integrating bio-based components as alternatives to conventional materials into building envelopes, aligning with project expectations and prevailing standards for curtain wall façade solutions. Notably, the designed façade system meets technical conditions and research objectives. Nevertheless, the paper underscores the need for further refinements to facilitate solution industrialization and explore broader market applicability focusing on the biocomposite profile.

25 March 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
LVLaura Vandi
Laura Vandi
MCMaria Teresa Calcagni
Maria Teresa Calcagni
FBFrancesco Belletti
Francesco Belletti
GPgiuseppe pandarese
giuseppe pandarese
MMMilena Martarelli
Milena Martarelli
Alessandro PracucciAlessandro Pracucci
Alessandro Pracucci
This paper details the comprehensive activities conducted in a laboratory setting to assess the Structural Health Monitoring (SHM) of prefabricated building envelopes. Aimed at enhancing the structural evaluation of buildings, the focus of this research lies in employing nondestructive sensors for SHM with the objective to advance in the understanding and assessment of facade conditions. The paper outlines the methodologies employed, starting with a modal analysis to define the structural vibration's modal frequency. Subsequently, tests were defined and executed to validate building envelope compliance in case of stress typical of high-rise building. Throughout these tests, continuous monitoring of the façade was conducted using both conventional (accelerometers, extensimeter washers) and non-conventional sensors (Fiber Optic Sensing) The gathered data underwent thorough processing and analysis to provide an overall perspective on the structure's behavior during the stress test. The investigation aimed to identify whether specific physical phenomena correlate with distinct signals and to evaluate if continuous façade monitoring over the building's lifespan aids in preventing potential structural damage. Moreover, two modal analyses were conducted to compare final data and frequencies with earlier data, enabling the detection of any structural alterations. The results from compliance testing and structural analysis yielded noteworthy insights contributing to the evolving field of structural health monitoring, offering valuable findings that advance our ability to proactively manage and maintain the integrity of building structures.

18 January 2021 in Proceedings
Verified
Conference Paper
Open access
PDF file
Alessandro PracucciAlessandro Pracucci
Alessandro Pracucci
SMSara Magnani
Sara Magnani
LVLaura Vandi
Laura Vandi
OCOscar Casadei
Oscar Casadei
AUAmaia Uriarte
Amaia Uriarte
MVMichele Vavallo
Michele Vavallo
The nearly Zero Energy building (nZEB) renovation market is currently the key feature in the construction sector. RenoZEB aims to develop a systematic approach for retrofitting by assembling different technologies in a plug and play building envelope. This paper presents the methodology used to transform the RenoZEB concept in the design system. A multi-criteria decision matrix is used for the selection of the best façade technologies within the market while the analysis of the existing building conditions allows to develop a replicable approach for designing deep retrofitting intervention through a plug&play façade. The methodology appears to be a valuable support for the selection of technologies and allows to define a design guideline for the envelope.