satoshi fujii

Dr. satoshi fujii


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
NMNobuo Misawa
Nobuo Misawa
SFsatoshi fujii
satoshi fujii
KKKoki Kamiya
Koki Kamiya
TOToshihisa Osaki
Toshihisa Osaki
STShoji Takeuchi
Shoji Takeuchi
This paper describes a method for a bilayer lipid membrane (BLM) formation using a perforated sheet along with an open chamber. Microscopic observation of the formed membrane showed a typical droplet interface bilayer. We proved that the formed membrane was a BLM based on electrical measurements of the membrane protein α-hemolysin, which produces nanopores in BLMs. Unlike the conventional approach for BLM formation based on the droplet contact method, this method provides aqueous surfaces with no organic solvent coating layer. Hence, this method is suitable for producing BLMs that facilitate the direct addition of chemicals into the aqueous phase.

18 December 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
YIYoshihisa Ito
Yoshihisa Ito
YIYusuke Izawa
Yusuke Izawa
TOToshihisa Osaki
Toshihisa Osaki
KKKoki Kamiya
Koki Kamiya
NMNobuo Misawa
Nobuo Misawa
STShoji Takeuchi
Shoji Takeuchi
Lipid-bilayer devices have been studied for on-site sensors in the fields of diagnosis, food and environmental monitoring, and safety/security inspection. In this paper, we propose a lipid-bilayer-on-a-cup device for serial sample measurements using a pumpless solution exchange procedure. The device consists of a millimeter-scale cylindrical cup with vertical slits which is designed to steadily hold an aqueous solution and exchange the sample by simply fusing and splitting the solution with an external solution. The slit design was experimentally determined by the capabilities of both the retention and exchange of the solution. Using the optimized slit, a planar lipid bilayer was reconstituted with a nanopore protein at a microaperture allocated to the bottom of the cup, and the device was connected to a portable amplifier. The solution exchangeability was demonstrated by observing the dilution process of a blocker molecule of the nanopore dissolved in the cup. The pumpless solution exchange by the proposed cup-like device presents potential as a lipid-bilayer system for portable sensing applications.