Xiaoxiao Kong

Dr. Xiaoxiao Kong

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2020 in High Voltage
Verified
Journal Article
Open access
PDF file
BDBoxue Du
Boxue Du
HSHanlei Sun
Hanlei Sun
JJJinpeng Jiang
Jinpeng Jiang
Xiaoxiao KongXiaoxiao Kong
Xiaoxiao Kong
WYWei Yang
Wei Yang
The electric field distribution is determined for the design and long‐term performance of bushing yet gets complicated when coupled with temperature due to the highly temperature‐dependent conductivity of insulation. An electrothermal coupling model is established based on a ±800 kV converter transformer valve‐side bushing. The measured temperature‐dependent conductivity of insulation is adopted and fitted. The electric field distribution inside a condenser core under the influence of temperature was investigated, and the related mechanism was analysed, considering the different voltage forms, loading currents, and changeable ambient conditions. The temperature gradient within the condenser core is verified, and the electric field migration is observed. It is indicated that the electric field strength shows a strong dependence on temperature and increases along the radial direction. The maximum field strength appears at the outmost shield layer under the operating voltage and the load current 4500 A, which is higher than that under the DC long‐term withstand voltage of 1455 kV without thermal stress. The increased load current, decreased oil temperature, and enhanced valve hall temperature will lead to more serious electric field distortion, and unacceptable dielectric stress may occur. More attention should be paid to the design and operation of bushing for DC applications.

31 January 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
BDB. X. Du
B. X. Du
YZY. Zhang
Y. Zhang
Xiaoxiao KongXiaoxiao Kong
Xiaoxiao Kong
HLHucheng Liang
Hucheng Liang
In this article, electrical tree morphological features in epoxy resin under tensile and compressive stress are investigated. The applied tensile and compressive stress varies from 0 to 30 MPa, whose direction is perpendicular to the needle electrode. The obtained results show that the tensile stress accelerates the tree growth, especially in the direction parallel to the tensile stress. With the increasing compressive stress, both the tree length and the corresponding accumulated damage decrease first and subsequently increase. By comparing the tree distribution in parallel and vertical directions, it is found that the tree mainly propagates to the ground electrode under the compressive stress. A tree growth curve is proposed to explain the experimental results, which reveals the defect generation and the tree propagation driven by both electrical and mechanical stresses. The growth curve can predict the tree-induced dielectric breakdown in epoxy resin under mechanical stress.

10 October 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Jin LiJin Li
Jin Li
PGPengxiang Guo
Pengxiang Guo
Xiaoxiao KongXiaoxiao Kong
Xiaoxiao Kong
YWYifang Wang
Yifang Wang
FLFan Li
Fan Li
BDBoxue Du
Boxue Du
The dielectric properties of epoxy resin mainly depend on its microstructures, especially the curing degree. In this paper, the reaction process of diglycidyl ether of bisphenol A (DGEBA)/methyl hexahydrophthalic anhydride (MHHPA) system is studied by differential scanning calorimetry, and samples with different curing degrees are prepared by regulating the curing temperature and time. The evolution of microstructure during epoxy resin crosslinking is simulated by molecular dynamics simulation. It is found that the effect of the curing degree on dielectric properties can be attributed to the distribution of polar groups and the mobility of chain segments, while the contribution of free volume is insignificant. With the increase of the curing degree, the epoxy group at the chain end is transformed into an ester group with weaker polarity, as well as the epoxy molecular segments are combined more closely and the mobility of molecules decreases, resulting in an improvement in the dielectric properties of the epoxy resin.

12 March 2021 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
BDBoxue Du
Boxue Du
XDXiaoyu Du
Xiaoyu Du
Xiaoxiao KongXiaoxiao Kong
Xiaoxiao Kong
JLJin Li
Jin Li
ZLZhijian Li
Zhijian Li
XLXu Li
Xu Li
Discharge failure mechanism of the cable buffer layer is investigated in this paper by the analysis of causes and characteristics of partial discharge (PD) behaviours in the case of failure. The obtained results show that both the volume resistivity and the surface resistance of the buffer layer increase as the relative humidity is elevated. It is found that the electric field distribution inside the buffer layer is distorted when there is poor contact condition and aggravated with the increase of the volume resistivity by the finite element analysis. PD behaviours analysis shows that the PD intensity is closely related to the contact state of the buffer layer, and hence the latter can be reflected by statistical parameters like the maximum pulse amplitude and the average equivalent frequency. The conclusions indicate that the electric field distortion is caused by the variation of the contact state of the buffer layer and the deterioration, which is responsible for the occurrence of PD. Therefore, the PD detection for the suspected faulty cables provides an effective method for the state evaluation of the buffer layer.

25 November 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Jin LiJin Li
Jin Li
PGPengxiang Guo
Pengxiang Guo
Xiaoxiao KongXiaoxiao Kong
Xiaoxiao Kong
YWYifang Wang
Yifang Wang
YYYong Yang
Yong Yang
BDBoxue Du
Boxue Du
The addition of accelerator reduces the curing reaction temperature, changes the curing reaction process, and affects the morphology of the crosslinking structure, which would lead to the difference in the dielectric properties of the epoxy resin. In this study, the curing behaviors and dielectric properties of diglycidyl ether of bisphenol A (DGEBA)/methyl hexahydrophthalic anhydride (MHHPA) were investigated with respect to the contents of the curing accelerator, Tris-(dimethylaminomethyl) phenol (DMP-30). The curing behavior of epoxy resin was studied by differential scanning calorimetry (DSC), and it was found that the system conforms to the Sestak–Berggren kinetic model [SB ( ${m},{n}{)}$ ]. The accelerator content has a saturation effect on the dielectric properties of the epoxy resin curing sample, and excessive content can lead to the increase of dielectric constant and loss and decrease of breakdown strength. The cured sample with 0.5% accelerator addition has the best dielectric properties and the highest breakdown strength. The analysis concludes that the optimum accelerator content allows for a more rational curing crosslinking network.

20 November 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
BDBoxue Du
Boxue Du
RXRundong Xue
Rundong Xue
Xiaoxiao KongXiaoxiao Kong
Xiaoxiao Kong
YCYun Chen
Yun Chen
In this article, aramid fiber surface is treated by dielectric barrier discharge (DBD) plasma, and various aramid fiber reinforced epoxy composites (AFRCs) are prepared to investigate the effects of plasma modification on the dielectric and mechanical properties. It is found that plasma treatment could change the roughness and active chemical groups content of aramid fiber surface, which is beneficial to the improvement of interfacial bonding strength between fiber and epoxy resin. After appropriate plasma treatment of treatment time with 2 min and Argon flow rate with 2 L/min, the conductivity, dielectric loss, and integration charge ${Q}$ ( ${t}$ ) of AFRC are significantly reduced, and the breakdown strength is increased from 29.2 to 32.6 kV/mm. The shear strength is enhanced from 29.38 to 58.93 MPa. The improvement in the dielectric and mechanical properties of AFRC is attributed to the increased interfacial bonding strength and the reduced interfacial polarization. This article provides a way to improve the dielectric and mechanical properties of AFRC, which is of great significance for its application in insulation rod for gas-insulated metal-enclosed switchgear (GIS).