20 January 2023 in IEEE Transactions on Plasma Science
An overview of the recent operations and the main results of cesium injection in the Source for the Production of Ions of Deuterium Extracted from Rf plasma (SPIDER) negative ion source are described in this contribution. In experiments without cesium injection, all SPIDER plants were tested to verify the basic expectations on the operational parameters (e.g., electron cooling effectiveness of magnetic filter field) and to determine its operational region. For beam properties, it was shown that the current density varies across the beam in the vertical direction. In preliminary cesium experiments, the expected increase of negative ion current and simultaneous decrease of co-extracted electrons were found, along with the influence of the control parameters (polarization of the plasma electrodes, magnetic filter field) on the SPIDER beam uniformity in the horizontal and vertical directions. It was shown that non-Gaussian tails can be identified in the angular distribution on the plane perpendicular to the beam propagation direction. Stray particles, nonhomogeneous beam and large divergence might result in unexpected heat and particle loads over ITER neutral beam injector (NBI) accelerator grids; it is the goal of SPIDER to assess and possibly to identify suitable methods for controlling these beam features. A major shutdown, planned for late 2021, to solve the issues identified during the operation and to carry out scheduled modifications, is outlined. Such improvements are expected to allow SPIDER to pursue the ITER requirements in terms of negative ion current, electron-to-ion ratio, and beam duration.
8 July 2022 in IEEE Transactions on Plasma Science
The Source for the Production of Ions of Deuterium Extracted from an RF plasma (SPIDER) experiment is the full-size test-bed of the negative ion sources of ITER neutral beams. It aims to extract and accelerate more than 350 A/m $^{2}$ of negative hydrogen ions from 1280 apertures, distributed over a surface of approximately 2 m $^{2}$ . To assess plasma uniformity, SPIDER is equipped with bi-dimensional arrays of Langmuir probes, covering the plasma grid (PG) and the bias plate (BP) plasma-facing surfaces. These sets of diagnostics are routinely used during the ion source operation and allow to investigate the plasma properties in the so-called source expansion and extraction region. The dependencies of plasma parameters on source operation parameters such as RF power, pressure, magnetic filter field, PG, and BP biases are reported and used to evaluate the uniformity of the plasma, showing the presence of plasma drifts due to the magnetic field. Finally, the correlation between plasma and beam uniformity is assessed.
27 April 2023 in Journal of Vacuum Science & Technology B
An improvement for the vacuum system of the multidriver radio frequency (RF) prototype negative ion source SPIDER has been developed, to allow operating at high RF power, while minimizing the breakdown probability on the outside of the plasma source. A first-of-its-kind large nonevaporable getter (NEG) pump, based on a modular design of 384 cartridges totaling about 350 kg of ZAO® alloy (composed by Zr-Ti-V-Al) with an installed pumping speed at a room temperature of 330 m3/s for hydrogen, will complement the existing pumping system, based on eight cryogenic pumps and four turbomolecular pumps totaling about 90 m3/s in hydrogen. The vessel pressure during absorption is expected to be between 20 and 40 mPa, while during the getter regeneration, the peak operating pressure will be around 2 Pa. The NEG pump will use an additional vessel module, with integrated thermal shields to protect the in-vessel components during activation and regeneration of the pump, to be carried out at temperatures in the range of 550–600 °C. Integrated thermal analyses were carried out to verify the low heat load on pre-existing in-vessel components with a low limit of acceptable temperature, and to provide boundary conditions for the mechanical verifications of the pump structure. The scenario of cyclic hydrogen load was calculated considering the SPIDER operation modes, the expected gas throughput, and the cumulated load to the pump, to determine the regeneration temperature and auxiliary pumping necessary to make the regeneration duration compatible with the high availability of the system. The upgrade of the auxiliary pumping system is also described, as well as the mitigation of air or water exposure risk during regeneration of the NEG pump.
1 January 2020 in Review of Scientific Instruments
The cesium ovens for the prototype source of the ITER neutral beam injectors are currently tested in the CAesium Test Stand (CATS) facility, with a background pressure of 10−6 mbar. Different diagnostics are here installed: two Langmuir–Taylor detectors allow us to determine the Cs vapour evaporation rate from the oven and the Cs density at different positions in the vacuum chamber; and laser absorption spectroscopy is used to measure the density integrated over a line of sight and a quartz crystal microbalance to detect the cesium mass deposited in time over a surface. In this paper, we present a model to describe the dynamic equilibrium in the evaporation chamber of CATS with the first oven tested in order to gain information about the Cs sticking coefficient at the walls. The model hence includes sticking and energy accommodation of the Cs atoms to the walls, calculates the flux density at the surfaces, and provides the Cs atom density at any location in the volume. By this model, we simulate the Cs evaporation and the equilibrium density, comparing the modeled results with the experimental data. As a result, a sticking coefficient of 2% is obtained.
19 May 2022 in IEEE Transactions on Plasma Science
This contribution describes the commissioning and first operation of a fixed triple Langmuir probe in source for the production of ions of deuterium extracted from a radio frequency plasma (SPIDER), the full-scale prototype of the negative-ion source for ITER neutral beam injectors. This diagnostic is capable of measuring the time evolution of the main plasma features for the entire duration of the plasma discharge, allowing to correlate local plasma properties, such as density, electron temperature, and plasma potential, to control parameters, i.e., filter field intensity, radio frequency (RF) power, and bias voltages. The probe was installed on the rear wall of the expansion chamber, and this being a region of specific interest for the operation with cesium since it may act as a reservoir, contributing to the cesium recycling toward the extraction region. Furthermore, the capability of the triple probe arrangement of measuring the instantaneous plasma density and electron temperature (also at high frequency) has been exploited to investigate the modulation of plasma parameters.