Han-Ping Huang

Dr. Han-Ping Huang

National Yang Ming Chiao Tung University
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2010 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SYShih-Mo Yang
Shih-Mo Yang
TYTung-Ming Yu
Tung-Ming Yu
Han-Ping HuangHan-Ping Huang
Han-Ping Huang
MKMeng-Yen Ku
Meng-Yen Ku
LHLong Hsu
Long Hsu
CLCheng-Hsien Liu
Cheng-Hsien Liu
We develop light-driven optoelectronic tweezers based on the organic photoconductive material titanium oxide phthalocyanine. These tweezers function based on negative dielectrophoresis (nDEP). The dynamic manipulation of a single microparticle and cell patterning are demonstrated by using this light-driven optoelectronic DEP chip. The adaptive light patterns that drive the optoelectronic DEP onchip are designed by using Flash software to approach appropriate dynamic manipulation. This is also the first reported demonstration, to the best of our knowledge, for successfully patterning such delicate cells from human hepatocellular liver carcinoma cell line HepG2 by using any optoelectronic tweezers.

18 October 2017 in Entropy
Verified
Journal Article
Open access
PDF file
CHChang Francis Hsu
Chang Francis Hsu
SWSung-Yang Wei
Sung-Yang Wei
Han-Ping HuangHan-Ping Huang
Han-Ping Huang
LHLong Hsu
Long Hsu
Sien ChiSien Chi
Sien Chi
CPChung-Kang Peng
Chung-Kang Peng
Healthy systems exhibit complex dynamics on the changing of information embedded in physiologic signals on multiple time scales that can be quantified by employing multiscale entropy (MSE) analysis. Here, we propose a measure of complexity, called entropy of entropy (EoE) analysis. The analysis combines the features of MSE and an alternate measure of information, called superinformation, useful for DNA sequences. In this work, we apply the hybrid analysis to the cardiac interbeat interval time series. We find that the EoE value is significantly higher for the healthy than the pathologic groups. Particularly, short time series of 70 heart beats is sufficient for EoE analysis with an accuracy of 81% and longer series of 500 beats results in an accuracy of 90%. In addition, the EoE versus Shannon entropy plot of heart rate time series exhibits an inverted U relationship with the maximal EoE value appearing in the middle of extreme order and disorder.

11 April 2011 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
SYShih-Mo Yang
Shih-Mo Yang
TYTung-Ming Yu
Tung-Ming Yu
Han-Ping HuangHan-Ping Huang
Han-Ping Huang
MKMeng-Yen Ku
Meng-Yen Ku
STSheng-Yang Tseng
Sheng-Yang Tseng
CLCheng-Hsien Liu
Cheng-Hsien Liu
Microbubbles have a variety of applications in science and biological technology. Here, we demonstrate the manipulation of the picoliter gas bubble (picobubble) based on the optoelectronic-mechanism. The organic photoconductive material, titanium oxide phthalocyanine (TiOPc), was developed to make the light-sensitive substrate of this optoelectronic chip. The virtual electrodes are formed by projecting the dynamic light pattern onto TiOPc layer for generating the desired nonuniform electric field. The picobubble suspended in silicone oil can be manipulated with the velocity of 40–50 μm/s . The driving force up to 160 pico-Newtons could be generated for manipulating a gas bubble of 300 picoliters.

23 July 2019 in IEEE Access
Verified
Journal Article
Open access
Han-Ping HuangHan-Ping Huang
Han-Ping Huang
SWSung-Yang Wei
Sung-Yang Wei
HCHsuan-Hao Chao
Hsuan-Hao Chao
CHChang Francis Hsu
Chang Francis Hsu
LHLong Hsu
Long Hsu
SCSien Chi
Sien Chi
Mode mixing is a limitation of the empirical mode decomposition (EMD) method appropriate for physiological signal analysis. In 2008, Boundary Condition Map presented by Rilling and Flandrin provided the efficiency of separating the two components of a two-tone signal as a function of their amplitude and frequency ratios. Till 2019, their findings were still applied. However, their maps only give an uncertainty-like efficiency of mode mixing separation for two-tone signals. In this paper, we propose a criterion for mode mixing separation in EMD, which provides a binary judgement on mode mixing separation instead of the above efficiency. By comparing the slopes of the two components, we found that the phenomenon of mode mixing occurs as the extrema of the high-tone component are suppressed by the lowtone component. Under this condition, the criterion shows the relation among their amplitude ratio, frequency ratio, and relative phase between the two components. Given with values of the three parameters, one can affirm whether the two components are mixed according to the criterion. Accordingly, we derive a black/white three-dimensional (3D) map which plots the binary result of mode mixing in black or white as a function of the three parameters. Our map agrees with Rilling’s map and the results obtained from our gait analysis. Among the 23 sets of center-of-mass trajectory signals, six sets encountered the mode mixing problem and their coordinates of the three parameters were found in the black region of the map while the other 17 sets were in the white region.

31 March 2021 in Entropy
Verified
Journal Article
Open access
PDF file
Han-Ping HuangHan-Ping Huang
Han-Ping Huang
CHChang Francis Hsu
Chang Francis Hsu
YMYi-Chih Mao
Yi-Chih Mao
LHLong Hsu
Long Hsu
Sien ChiSien Chi
Sien Chi
Gait stability has been measured by using many entropy-based methods. However, the relation between the entropy values and gait stability is worth further investigation. A research reported that average entropy (AE), a measure of disorder, could measure the static standing postural stability better than multiscale entropy and entropy of entropy (EoE), two measures of complexity. This study tested the validity of AE in gait stability measurement from the viewpoint of the disorder. For comparison, another five disorders, the EoE, and two traditional metrics methods were, respectively, used to measure the degrees of disorder and complexity of 10 step interval (SPI) and 79 stride interval (SI) time series, individually. As a result, every one of the 10 participants exhibited a relatively high AE value of the SPI when walking with eyes closed and a relatively low AE value when walking with eyes open. Most of the AE values of the SI of the 53 diseased subjects were greater than those of the 26 healthy subjects. A maximal overall accuracy of AE in differentiating the healthy from the diseased was 91.1%. Similar features also exists on those 5 disorder measurements but do not exist on the EoE values. Nevertheless, the EoE versus AE plot of the SI also exhibits an inverted U relation, consistent with the hypothesis for physiologic signals.

27 November 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SWSung-Yang Wei
Sung-Yang Wei
HCHsuan-Hao Chao
Hsuan-Hao Chao
Han-Ping HuangHan-Ping Huang
Han-Ping Huang
CHChang Francis Hsu
Chang Francis Hsu
SLSheng-Hsiang Li
Sheng-Hsiang Li
LHLong Hsu
Long Hsu
Background: Total motile sperm count (TMSC) and curvilinear velocity (VCL) are two important parameters in preliminary semen analysis for male infertility. Traditionally, both parameters are evaluated manually by embryologists or automatically using an expensive computer-assisted sperm analysis (CASA) instrument. The latter applies a point-tracking method using an image processing technique to detect, recognize and classify each of the target objects, individually, which is complicated. However, as semen is dense, manual counting is exhausting while CASA suffers from severe overlapping and heavy computation. Methods: We proposed a simple frame-differencing method that tracks motile sperms collectively and treats their overlapping with a statistical occupation probability without heavy computation. The proposed method leads to an overall image of all of the differential footprint trajectories (DFTs) of all motile sperms and thus the overall area of the DFTs in a real-time manner. Accordingly, a theoretical DFT model was also developed to formulate the overall DFT area of a group of moving beads as a function of time as well as the total number and average speed of the beads. Then, using the least square fitting method, we obtained the optimal values of the TMSC and the average VCL that yielded the best fit for the theoretical DFT area to the measured DFT area. Results: The proposed method was used to evaluate the TMSC and the VCL of 20 semen samples. The maximum TMSC evaluated using the method is more than 980 sperms per video frame. The Pearson correlation coefficient (PCC) between the two series of TMSC obtained using the method and the CASA instrument is 0.946. The PCC between the two series of VCL obtained using the method and CASA is 0.771. As a consequence, the proposed method is as accurate as the CASA method in TMSC and VCL evaluations. Conclusion: In comparison with the individual point-tracking techniques, the collective DFT tracking method is relatively simple in computation without complicated image processing. Therefore, incorporating the proposed method into a cell phone equipped with a microscopic lens can facilitate the design of a simple sperm analyzer for clinical or household use without advance dilution.