The objective of this study was to achieve higher efficiency of a PV system while reducing of the cost of energy generation. Concentration photovoltaics was employed in the present case as it uses low cost reflectors to enhance the efficiency of the PV system and simultaneously reduces the cost of electricity generation. For this purpose a V-trough integrated with the PV system was employed for low concentration photovoltaic (LCPV). Since the electrical output of the concentrating PV system is significantly affected by the temperature of the PV cells, the motivation of the research also included studying the ability to actively cool PV cells to achieve the maximum benefit. The optical, thermal and electrical performance of the V-trough PV system was theoretically modeled and validated with experimental results. Optical modeling of V-trough was carried out to estimate the amount of enhanced absorbed radiation. Due to increase in the absorbed radiation the module temperature was also increased which was predicted by thermal model. Active cooling techniques were studied and the effect of cooling was analyzed on the performance of V-trough PV system. With absorbed radiation and module temperature as input parameters, electrical modeling was carried out and the maximum power was estimated. For the V-trough PV system, experiments were performed for validating the numerical models and very good agreement was found between the two.
18 February 2019 in Journal of Energy Resources Technology
A two-dimensional steady developing fluid flow and heat transfer through a periodic wavy channel with staggered walls is studied numerically for a fluid with a Prandlt number of 0.7 and compared to flow through the corresponding wavy channel with nonstaggered walls. The lower wall is displaced relative to the upper wall by one-fourth, one-half, and three-fourths of the total one-module length. Sinusoidal and arc-shaped configurations are studied for a fixed set of geometric parameters. Periodically fully developed flow is attained downstream of the first module of the 10 modules considered in this study. Sinusoidal channels with one-half displacement provide lower normalized pressure drop values when compared to all other channels (staggered and nonstaggered) considered in this study. The module average Nusselt number increases monotonically with Reynolds number. Moreover, the heat transfer enhancement ratio for arc-shaped channels with three-fourths displacement is as high as 5.7%.
3 August 2016 in Advances in Mechanical Engineering
In this study, the volumetric entropy generation rate is analyzed in sharp edge wavy channels. A two-dimensional steadily developing fluid flow is considered. Air is considered as the working fluid in the numerical analysis. Two parameters, Reynolds number (Re) and the horizontal-pitch-to-module-length ratio, are considered as variables. The effect of these variables on the volumetric entropy generation is analyzed numerically using a finite volume technique. Domain discretization was made using a body-fitted coordinate system. The volumetric entropy generation profiles for varying Re number and the horizontal pitch are discussed. It is found that the total entropy generation increases considerably with the increase in the Re number. For the Re number range of 25–400, the total entropy generation in the second module near the inlet varied from 0.38 to 18922.67 W/K, respectively. However, the entropy generation rate was found to decrease along the channel through the modules, as the periodic steady conditions were approached in the subsequent modules.
28 June 2019 in Journal of Energy Resources Technology
The rheological model for yield stress exhibiting fluid and the basic laws for fluid flow and transport of heat and mass are used for the formulation of problems associated with the enhancement of heat and mass due to dispersion of nanoparticles in Casson. The heat and mass transfer obey non-Fourier’s laws and the generalized Fick’s law, respectively. Model problems are incorporated by thermal relaxation times for heat and mass. Transfer of heat energy and relaxation time are inversely proportional, and the same is the case for mass transport and concentration relaxation time. A porous medium force is responsible for controlling the momentum thickness. The yield stress parameter and diffusion of momentum in Casson fluid are noticed to be inversely proportional with each other. The concentration gradient enhances the energy transfer, and temperature gradient causes an enhancement diffusion of solute in Casson fluid. FEM provides convergent solutions. The relaxation time phenomenon is responsible for the restoration of thermal and solutal changes. Due to that, the thermal and solutal equilibrium states can be restored. The phenomenon of yield stress is responsible for controlling the momentum boundary layer thickness. A porous medium exerts a retarding force on the flow, and therefore, a deceleration in flow is observed. The thermal efficiency of Casson fluid is greater than the thermal efficiency of Casson fluid.