In order to study the effect of inorganic salt additives on the surface tension of a sodium dodecylbenzene sulfonate (SDBS) solution, the surface tension of the mixed system of six common inorganic salt additives, NaCl, CaCl2, AlCl3, Na2SO4, Na2CO3, and NaHCO3, and SDBS was measured, and the effects of the inorganic salt types, surfactant concentrations and inorganic salt concentrations on the surface tension of the SDBS solution were studied. On this basis, three inorganic salts, NaCl, CaCl2 and Na2SO4, were selected, and their effects on the critical micelle concentration (CMC) of the SDBS solution were studied. The experimental results showed that different inorganic salts had different effects on the surface tension of the SDBS solution. The order of effect of the six inorganic salts on the surface tension of the SDBS solution was CaCl2 > NaCl > Na2SO4 > NaHCO3 > Na2CO3 > AlCl3; when the mass fraction of the SDBS solution is high, the influence of the inorganic salts on the surface tension of the SDBS solution is relatively small; with an increase in the concentration of the preferred inorganic salt additives, the surface tension of the SDBS solution decreases first, then tends to be stable, and then increases; a reduction in the critical micelle concentration by the three selected inorganic salt additives shows the trend of 0.7% NaCl > 0.5% CaCl2 > 0.5% Na2SO4.
A wideband RF logarithmic power detector with large dynamic range is presented in this work. The power detector fabricated in 180-nm SiGe process employs the successive approximation technique over a 6-stage cascaded amplifier chain. A cross-coupled cascode amplifier architecture is proposed to expand bandwidth up to 8GHz. With a temperature compensation circuit and a DC offset compensation loop, the detector provides consistent logarithmic performance at different temperatures in band, which can be applied in highly reliable RF systems. The measured input dynamic range is larger than 50dB in 1MHz∼8GHz with less than ±1dB error and 55dB at 8GHz with less than ±3dB error. The measured temperature drift is less than ±1.0dB at 5GHz over the temperature range from -40 to 85℃.
This paper proposes an on-chip time-to-digital converter (TDC) named pulse delay and capture circuit (PDCC), dedicated to single-event transient (SET) pulse measurement for radiation characterization of flash-based FPGAs. To address the inherent trade-offs of mainstream vernier delay line (VDL) and snapshot TDC schemes, the proposed PDCC employs a 16-stage single-chain self-triggering capture circuit with a SET indicator flip-flop, incorporates heterogeneous-cell ring-oscillator-based process-voltage-temperature (PVT) calibration, and avoids the need for resource-intensive first-in-first-out (FIFO) buffers. Implemented on a 130 nm A3PE600 flash-based FPGA, the PDCC achieves a nominal theoretical resolution of 640 ps and a nominal theoretical dynamic range of 0.64–10.24 ns, with 53.5% lower logic resource overhead than the VDL benchmark. Heavy-ion irradiation experiments validate the measurement capability and reveal asymmetric SET pulse propagation evolution characterized by positive-pulse broadening and negative-pulse attenuation, as well as sensitivity disparities among logic gates, which are attributed to the physical implementation of internal transistor networks within the VersaTile. A multi-criteria assessment based on the Simple Additive Weighting (SAW) method, evaluating resolution, dynamic range, logic resource overhead, and measured SET pulse width, yields an overall performance score (OPS) of 1.43, corresponding to a 43% higher score relative to the VDL baseline.
Hall-effect sensors are pervasive in magnetic-field measurement applications, including current sensing and position detection, owing to their excellent compatibility with standard CMOS processes. However, the inherent offset and temperature drift of silicon-based Hall elements remain a paramount obstacle to achieve high precision. This paper presents a fully integrated angle sensor chip that addresses this challenge. Implemented in a 0.35 μm CMOS process, the sensor incorporates four cross-shaped Hall elements arranged in an orthogonal array as a non-contact Hall-permanent magnet configuration, which enables absolute angular encoding across a full 0–360° range. Experimental characterisation demonstrates a low noise floor of 0.087° (3σ), validating the effectiveness of the proposed architecture for high-accuracy angular measurement.