Keun-Tae Kim

Prof. Keun-Tae Kim

Korea Institute of Science and Technology (KIST)
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2016 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
Keun-Tae KimKeun-Tae Kim
Keun-Tae Kim
HSHeung-Il Suk
Heung-Il Suk
SLSeong-Whan Lee
Seong-Whan Lee
In this work, we propose a novel brain-controlled wheelchair, one of the major applications of brain-machine interfaces (BMIs), that allows an individual with mobility impairments to perform daily living activities independently. Specifically, we propose to use a steady-state somatosensory evoked potential (SSSEP) paradigm, which elicits brain responses to tactile stimulation of specific frequencies, for a user's intention to control a wheelchair. In our system, a user had three possible commands by concentrating on one of three vibration stimuli, which were attached to the left-hand, right-hand, and right-foot, to selectively control the wheelchair. The three stimuli were associated with three wheelchair commands: turn-left, turn-right, and move-forward. From a machine learning perspective, we also devise a novel feature representation by combining spatial and spectral characteristics of brain signals. In order to validate the effectiveness of the proposed SSSEP-based system, we considered two different tasks: 1) a simple obstacle-avoidance task within a limited time and; 2) a driving task along the predefined trajectory of about 40 m length, where there were a narrow pathway, a door, and obstacles. In both experiments, we recruited 12 subjects and compared the average time of motor imagery (MI) and SSSEP-based controls to complete the task. With the SSSEP-based control, all subjects successfully completed the task without making any collision while four subjects failed it with MI-based control. It is also noteworthy that in terms of the average time to complete the task, the SSSEP-based control outperformed the MI-based control. In the other more challenging task, all subjects successfully reached the target location.

14 October 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
Keun-Tae KimKeun-Tae Kim
Keun-Tae Kim
CGCuntai Guan
Cuntai Guan
SLSeong-Whan Lee
Seong-Whan Lee
In recent years, electromyography (EMG)-based practical myoelectric interfaces have been developed to improve the quality of daily life for people with physical disabilities. With these interfaces, it is very important to decode a user's movement intention, to properly control the external devices. However, improving the performance of these interfaces is difficult due to the high variations in the EMG signal patterns caused by intra-user variability. Therefore, this paper proposes a novel subject-transfer framework for decoding hand movements, which is robust in terms of intra-user variability. In the proposed framework, supportive convolutional neural network (CNN) classifiers, which are pre-trained using the EMG data of several subjects, are selected and fine-tuned for the target subject via single-trial analysis. Then, the target subject's hand movements are classified by voting the outputs of the supportive CNN classifiers. The feasibility of the proposed framework is validated with NinaPro databases 2 and 3, which comprise 49 hand movements of 40 healthy and 11 amputee subjects, respectively. The experimental results indicate that, when compared to the self-decoding framework, which uses only the target subject's data, the proposed framework can successfully decode hand movements with improved performance in both healthy and amputee subjects. From the experimental results, the proposed subject-transfer framework can be seen to represent a useful tool for EMG-based practical myoelectric interfaces controlling external devices.

19 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JCJunhyuk Choi
Junhyuk Choi
Keun-Tae KimKeun-Tae Kim
Keun-Tae Kim
JiHyeok JeongJiHyeok Jeong
JiHyeok Jeong
Laehyun KimLaehyun Kim
Laehyun Kim
Song Joo LeeSong Joo Lee
Song Joo Lee
Hyungmin KimHyungmin Kim
Hyungmin Kim
This study aimed to develop an intuitive gait-related motor imagery (MI)-based hybrid brain-computer interface (BCI) controller for a lower-limb exoskeleton and investigate the feasibility of the controller under a practical scenario including stand-up, gait-forward, and sit-down. A filter bank common spatial pattern (FBCSP) and mutual information-based best individual feature (MIBIF) selection were used in the study to decode MI electroencephalogram (EEG) signals and extract a feature matrix as an input to the support vector machine (SVM) classifier. A successive eye-blink switch was sequentially combined with the EEG decoder in operating the lower-limb exoskeleton. Ten subjects demonstrated more than 80% accuracy in both offline (training) and online. All subjects successfully completed a gait task by wearing the lower-limb exoskeleton through the developed real-time BCI controller. The BCI controller achieved a time ratio of 1.45 compared with a manual smartwatch controller. The developed system can potentially be benefit people with neurological disorders who may have difficulties operating manual control.

29 April 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
Minji LeeMinji Lee
Minji Lee
HPHyeong-Yeong Park
Hyeong-Yeong Park
WPWanjoo Park
Wanjoo Park
Keun-Tae KimKeun-Tae Kim
Keun-Tae Kim
YKYun-Hee Kim
Yun-Hee Kim
JJJi-Hoon Jeong
Ji-Hoon Jeong
Robot-assisted motor training is applied for neurorehabilitation in stroke patients, using motor imagery (MI) as a representative paradigm of brain-computer interfaces to offer real-life assistance to individuals facing movement challenges. However, the effectiveness of training with MI may vary depending on the location of the stroke lesion, which should be considered. This paper introduces a multi-task electroencephalogram-based heterogeneous ensemble learning (MEEG-HEL) specifically designed for cross-subject training. In the proposed framework, common spatial patterns were used for feature extraction, and the features according to stroke lesions are shared and selected through sequential forward floating selection. The heterogeneous ensembles were used as classifiers. Nine patients with chronic ischemic stroke participated, engaging in MI and motor execution (ME) paradigms involving finger tapping. The classification criteria for the multi-task were established in two ways, taking into account the characteristics of stroke patients. In the cross-subject session, the first involved a direction recognition task for two-handed classification, achieving a performance of 0.7419 (±0.0811) in MI and 0.7061 (±0.1270) in ME. The second task focused on motor assessment for lesion location, resulting in a performance of 0.7457 (±0.1317) in MI and 0.6791 (±0.1253) in ME. Comparing the specific-subject session, except for ME on the motor assessment task, performance on both tasks was significantly higher than the cross-subject session. Furthermore, classification performance was similar to or statistically higher in cross-subject sessions compared to baseline models. The proposed MEEG-HEL holds promise in improving the practicality of neurorehabilitation in clinical settings and facilitating the detection of lesions.

1 February 2013
Verified
Conference Paper
Closed access
Keun-Tae KimKeun-Tae Kim
Keun-Tae Kim
TCTom Carlson
Tom Carlson
SLSeong-Whan Lee
Seong-Whan Lee
This paper presents a prototype for an electro-encephalogram (EEG) based brain-actuated wheelchair system using motor imagery. To overcome some of the limitations of other previous works, such as gaze dependence and unnecessary stops, five commands (left, left-diagonal, right, right-diagonal, and forward) were decoded based on the motor imagery correlates in EEG signals. Also, the system was modularized into three components: BCI control, and network. On the basis of the conclusions, we can expect a robust brain-actuated wheelchair system, which can allow the user's intention to control the wheelchair in multi-directional movements, thereby increasing the user's authority compared with many of the alternative approaches.

7 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JiHyeok JeongJiHyeok Jeong
JiHyeok Jeong
JCJun-Hyuk Choi
Jun-Hyuk Choi
Keun-Tae KimKeun-Tae Kim
Keun-Tae Kim
Song Joo LeeSong Joo Lee
Song Joo Lee
Dong-Joo KimDong-Joo Kim
Dong-Joo Kim
Hyungmin KimHyungmin Kim
Hyungmin Kim
Motor imagery (MI) brain–computer interfaces (BCIs) have been used for a wide variety of applications due to their intuitive matching between the user’s intentions and the performance of tasks. Applying dry electroencephalography (EEG) electrodes to MI BCI applications can resolve many constraints and achieve practicality. In this study, we propose a multi-domain convolutional neural networks (MD-CNN) model that learns subject-specific and electrode-dependent EEG features using a multi-domain structure to improve the classification accuracy of dry electrode MI BCIs. The proposed MD-CNN model is composed of learning layers for three domain representations (time, spatial, and phase). We first evaluated the proposed MD-CNN model using a public dataset to confirm 78.96% classification accuracy for multi-class classification (chance level accuracy: 30%). After that, 10 healthy subjects participated and performed three classes of MI tasks related to lower-limb movement (gait, sitting down, and resting) over two sessions (dry and wet electrodes). Consequently, the proposed MD-CNN model achieved the highest classification accuracy (dry: 58.44%; wet: 58.66%; chance level accuracy: 43.33%) with a three-class classifier and the lowest difference in accuracy between the two electrode types (0.22%, d = 0.0292) compared with the conventional classifiers (FBCSP, EEGNet, ShallowConvNet, and DeepConvNet) that used only a single domain. We expect that the proposed MD-CNN model could be applied for developing robust MI BCI systems with dry electrodes.