Erik Dumont

Dr. Erik Dumont

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
FIFrancesco Iacoponi
Francesco Iacoponi
Andrea CafarelliAndrea Cafarelli
Andrea Cafarelli
FFFrancesco Fontana
Francesco Fontana
TPTiziano Pratellesi
Tiziano Pratellesi
EDErik Dumont
Erik Dumont
LRLeonardo Ricotti
Leonardo Ricotti
In this paper, we stimulated M1-like macrophages (obtained from U937 cells) with low-intensity pulsed ultrasound (LIPUS) to lower pro-inflammatory cytokine production. A systematic screening of different frequencies, intensities, duty cycles, and exposure times was performed. The optimal stimulation conditions leading to a marked decrease in the release of inflammatory cytokines were determined to be 38 kHz, 250 mW/cm2, 20%, and 90 min, respectively. Using these parameters, we verified that up to 72 h LIPUS did not affect cell viability, resulting in an increase in metabolic activity and in a reduction of reactive oxygen species (ROS) production. Moreover, we found that two mechanosensitive ion channels (PIEZO1 and TRPV1) were involved in the LIPUS-mediated cytokine release modulation. We also assessed the role of the nuclear factor κB (NF-κB) signaling pathway and observed an enhancement of actin polymerization. Finally, transcriptomic data suggested that the bioeffects of LIPUS treatment occur through the modulation of p38 MAPK signaling pathway.

1 September 2021 in Ultrasonics
Verified
Journal Article
Open access
FFF. Fontana
F. Fontana
FIF. Iberite
F. Iberite
Andrea CafarelliAndrea Cafarelli
Andrea Cafarelli
AAA. Aliperta
A. Aliperta
GBG. Baldi
G. Baldi
LRLeonardo Ricotti
Leonardo Ricotti
This work aims to describe the development and validation of two low-intensity pulsed ultrasound stimulation systems able to control the dose delivered to the biological target. Transducer characterization was performed in terms of pressure field shape and intensity, for a high-frequency range (500 kHz to 5 MHz) and for a low-frequency value (38 kHz). This allowed defining the distance, on the beam axis, at which biological samples should be placed during stimulation and to exactly know the intensity at the target. Carefully designed retaining systems were developed, for hosting biological samples. Sealing tests proved their impermeability to external contaminants. The assembly/de-assembly time of the systems resulted ~3 min. Time-domain acoustic simulations allowed to precisely estimate the ultrasound beam within the biological sample chamber, thus enabling the possibility to precisely control the pressure to be transmitted to the biological target, by modulating the transducer's input voltage. Biological in vitro tests were also carried out, demonstrating the sterility of the system and the absence of toxic and inflammatory effects on growing cells after multiple immersions in water, over seven days.

19 February 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
APAllison Payne
Allison Payne
RMRobb Merrill
Robb Merrill
EMEmilee Minalga
Emilee Minalga
JHJ. Rock Hadley
J. Rock Hadley
HOHenrik Odéen
Henrik Odéen
JPJean Palussiere
Jean Palussiere
Objective: This paper presents and evaluates a breast-specific magnetic resonance guided focused ultrasound (MRgFUS) system. A first-in-human evaluation demonstrates the novel hardware, a sophisticated tumor targeting algorithm and a volumetric magnetic resonance imaging (MRI) protocol. Methods: At the time of submission, N = 10 patients with non-palpable T0 stage breast cancer have been treated with the breast MRgFUS system. The described tumor targeting algorithm is evaluated both with a phantom test and in vivo during the breast MRgFUS treatments. Treatments were planned and monitored using volumetric MR-acoustic radiation force imaging (MRARFI) and temperature imaging (MRTI). Results: Successful technical treatments were achieved in 80% of the patients. All patients underwent the treatment with no sedation and 60% of participants had analgesic support. The total MR treatment time ranged from 73 to 114 minutes. Mean error between desired and achieved targeting in a phantom was 2.9±1.8 mm while 6.2±1.9 mm was achieved in patient studies, assessed either with MRTI or MR-ARFI measurements. MRTI and MR-ARFI were successful in 60% and 70% of patients, respectively. Conclusion: The targeting accuracy allows the accurate placement of the focal spot using electronic steering capabilities of the transducer. The use of both volumetric MRTI and MR-ARFI provides complementary treatment planning and monitoring information during the treatment, allowing the treatment of all breast anatomies, including homogeneously fatty breasts.

31 May 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PCPaolo Cabras
Paolo Cabras
PAPierre Auloge
Pierre Auloge
FBFabrice Bing
Fabrice Bing
PRPramod Prabhakar Rao
Pramod Prabhakar Rao
SHStéphanie Hoarau
Stéphanie Hoarau
JVJonathan Vappou
Jonathan Vappou
Magnetic Resonance (MR) Imaging-guided High Intensity focused Ultrasound (MRgHIFU) is a non-invasive, non-ionizing thermal ablation therapy that is particularly interesting for the palliative or curative treatment of musculoskeletal tumors. We introduce a new modular MRgHIFU device that allows the ultrasound transducer to be positioned precisely and interactively over the body part to be treated. A flexible, MR-compatible supporting structure allows free positioning of the transducer under MRI/optical fusion imaging guidance. The same structure can be rigidified using pneumatic depression, holding the transducer rigidly in place. Targeting accuracy was first evaluated in vitro. The average targeting error of the complete process was found to be equal to 5.4 ± 2.2 mm in terms of focus position, and 4.7° ± 2° in terms of transducer orientation. First-in-man feasibility is demonstrated on a patient suffering from important, uncontrolled pain from a bone metastasis located in the forearm. The 81 × 47 × 34 mm3 lesion was successfully treated using five successive positions of the transducer, under real-time monitoring by MR Thermometry. Significant pain palliation was observed 3 days after the intervention. The system described and characterized in this study is a particularly interesting modular, low-cost MRgHIFU device for musculoskeletal tumor therapy.

22 December 2021 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
ASAngela Sorriento
Angela Sorriento
Andrea CafarelliAndrea Cafarelli
Andrea Cafarelli
Paolo SpinnatoPaolo Spinnato
Paolo Spinnato
ARA. Russo
A. Russo
GLGina Lisignoli
Gina Lisignoli
LRLeonardo Ricotti
Leonardo Ricotti
Objective: A repeatable and reliable follow-up of knee injuries would be desirable to prevent delayed diagnosis and to monitor the efficacy of the applied treatment over time. Ultrasound (US) techniques are an attractive option to this purpose, since they are safe, low-cost and non-invasive. However, its use in the clinical practice is limited by the high dependency on the operator’s experience. Hence, the objective of this study is to provide a standardization of the US image acquisition process for knee osteoarthritis (OA) allowing an extended clinical use of US technologies in this domain. Methods: Clinical specifications were provided by expert musculoskeletal radiologists thus identifying the subject poses and the US probe positions needed to evaluate the cartilage structure, signs of synovitis and joint effusion. Such considerations were used to derive the technical requirements needed for the development of a wearable brace equipped with specific openings to guide the correct placement of the probe. The feasibility of the developed wearable brace was tested on three healthy volunteers, which were asked to acquire informative US images, similar to the reference images performed by the musculoskeletal radiologist. Results: Thanks to the knee brace, the untrained subjects were able to self-acquire informative B-mode images comparable to the corresponding images acquired by an expert clinician. Discussion/Conclusion: The use of a knee brace intended for knee OA US diagnosis demonstrated the possibility to standardize the acquisition protocol and make its application achievable also for untrained subjects, representing a key step toward tele-ultrasonography.

31 May 2024 in IEEE Open Journal of Engineering in Medicine and Biology
Verified
Journal Article
Open access
Andrea CafarelliAndrea Cafarelli
Andrea Cafarelli
ASAngela Sorriento
Angela Sorriento
GMGiorgia Marola
Giorgia Marola
DADenise Amram
Denise Amram
FRFabien Rabusseau
Fabien Rabusseau
LRLeonardo Ricotti
Leonardo Ricotti
Goal: To evaluate the usability of different technologies designed for a remote assessment of knee osteoarthritis. Methods: We recruited eleven patients affected by mild or moderate knee osteoarthritis, eleven caregivers, and eleven clinicians to assess the following technologies: a wristband for monitoring physical activity, an examination chair for measuring leg extension, a thermal camera for acquiring skin thermographic data, a force balance for measuring center of pressure, an ultrasound imaging system for remote echographic acquisition, a mobile app, and a clinical portal software. Specific questionnaires scoring usability were filled out by patients, caregivers and clinicians. Results: The questionnaires highlighted a good level of usability and user-friendliness for all the technologies, obtaining an average score of 8.7 provided by the patients, 8.8 by the caregivers, and 8.5 by the clinicians, on a scale ranging from 0 to 10. Such average scores were calculated by putting together the scores obtained for the single technologies under evaluation and averaging them. Conclusions: This study demonstrates a high level of acceptability for the tested portable technologies designed for a potentially remote and frequent assessment of knee osteoarthritis.