Alicia Fernandez-Colino

Dr. Alicia Fernandez-Colino

Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
AFAlicia Fernandez-Colino
Alicia Fernandez-Colino
FWFrederic Wolf
Frederic Wolf
HKHans Keijdener
Hans Keijdener
SRStephan Rütten
Stephan Rütten
TSThomas Schmitz-Rode
Thomas Schmitz-Rode
PMPetra Mela
Petra Mela

21 September 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
FGFernando González-Pérez
Fernando González-Pérez
SASergio Acosta
Sergio Acosta
SRStephan Rütten
Stephan Rütten
CECaroline Emonts
Caroline Emonts
AKAlexander Kopp
Alexander Kopp
AFAlicia Fernandez-Colino
Alicia Fernandez-Colino
Chronic venous insufficiency (CVI) is a leading vascular disease whose clinical manifestations include varicose veins, edemas, venous ulcers, and venous hypertension, among others. Therapies targeting this medical issue are scarce, and so far, no single venous valve prosthesis is clinically available. Herein, we have designed a bi-leaflet transcatheter venous valve that consists of (i) elastin-like recombinamers, (ii) a textile mesh reinforcement, and (iii) a bioabsorbable magnesium stent structure. Mechanical characterization of the resulting biohybrid elastin-like venous valves (EVV) showed an anisotropic behavior equivalent to the native bovine saphenous vein valves and mechanical strength suitable for vascular implantation. The EVV also featured minimal hemolysis and platelet adhesion, besides actively supporting endothelialization in vitro, thus setting the basis for its application as an in situ tissue engineering implant. In addition, the hydrodynamic testing in a pulsatile bioreactor demonstrated excellent hemodynamic valve performance, with minimal regurgitation (<10%) and pressure drop (<5 mmHg). No stagnation points were detected and an in vitro simulated transcatheter delivery showed the ability of the venous valve to withstand the implantation procedure. These results present a promising concept of a biohybrid transcatheter venous valve as an off-the-shelf implant, with great potential to provide clinical solutions for CVI treatment.

10 February 2024 in Advanced Functional Materials
Verified
Journal Article
Open access
IMIkram El Maachi
Ikram El Maachi
ALAlexander Loewen
Alexander Loewen
SASergio Acosta
Sergio Acosta
SRStephan Rütten
Stephan Rütten
JRJose Carlos Rodriguez-Cabello
Jose Carlos Rodriguez-Cabello
AFAlicia Fernandez-Colino
Alicia Fernandez-Colino
Native tissues feature unique hierarchical designs, in which fiber units are arranged from the bottom up in anisotropic patterns. The processing of biomaterials into fibers, followed by their textile‐like assembly into complex patterns, is therefore a promising avenue to engineer native‐like tissue replacements. Here it is shown for the first time the fabrication of meter‐long hydrogel fibers prepared from engineered elastin using a microinjection system and exploiting the catalyst‐free click chemistry. Given their similarity to native elastin, the fabricated elastin‐like fibers achieved excellent stretching (500%) and recoiling performance. Moreover, the fabrication scheme is compatible with the implementation of a salt‐leaching gas‐foaming approach, resulting in highly porous elastin‐like fibers (the first of their kind). From the translation perspective, the fibers can be autoclaved, which allows for sterilization and long‐term storage. Human umbilical vein endothelial cells cultured on autoclaved fibers produced a confluent endothelial layer lining the fiber surface, in which the cells became aligned in response to physiological fiber stretching. It is also shown that these functional fibers can be assembled by weaving, braiding and knitting, with various spatial patterns. Overall, the elastin‐like fibers can be used as building blocks for the reconstruction of functional tissues using the principles of textile technology.

9 September 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
CBChristian Andreas Boehm
Christian Andreas Boehm
CDChristine Donay
Christine Donay
ALAndreas Lubig
Andreas Lubig
SRStephan Ruetten
Stephan Ruetten
MSMahmoud Sesa
Mahmoud Sesa
SJStefan Jockenhoevel
Stefan Jockenhoevel
The application of tissue-engineered heart valves in the high-pressure circulatory system is still challenging. One possible solution is the development of biohybrid scaffolds with textile reinforcement to achieve improved mechanical properties. In this article, we present a manufacturing process of bio-inspired fiber reinforcement for an aortic valve scaffold. The reinforcement structure consists of polyvinylidene difluoride monofilament fibers that are biomimetically arranged by a novel winding process. The fibers were embedded and fixated into electrospun polycarbonate urethane on a cylindrical collector. The scaffold was characterized by biaxial tensile strength, bending stiffness, burst pressure and hemodynamically in a mock circulation system. The produced fiber-reinforced scaffold showed adequate acute mechanical and hemodynamic properties. The transvalvular pressure gradient was 3.02 ± 0.26 mmHg with an effective orifice area of 2.12 ± 0.22 cm2. The valves sustained aortic conditions, fulfilling the ISO-5840 standards. The fiber-reinforced scaffold failed in a circumferential direction at a stress of 461.64 ± 58.87 N/m and a strain of 49.43 ± 7.53%. These values were above the levels of tested native heart valve tissue. Overall, we demonstrated a novel manufacturing approach to develop a fiber-reinforced biomimetic scaffold for aortic heart valve tissue engineering. The characterization showed that this approach is promising for an in situ valve replacement.

Verified
Journal Article
Open access
PDF file
Alp SarisoyAlp Sarisoy
Alp Sarisoy
SASergio Acosta
Sergio Acosta
JRJose Carlos Rodriguez-Cabello
Jose Carlos Rodriguez-Cabello
PCPhillip Czichowski
Phillip Czichowski
AKAlexander Kopp
Alexander Kopp
AFAlicia Fernandez-Colino
Alicia Fernandez-Colino
More than 260 million surgical procedures are performed worldwide each year. Although sutures and staples are widely used to reconnect tissues, they can cause further damage and increase the risk of infection. Bioadhesives have been proposed as an alternative to reconnect tissues. However, clinical adhesives that combine strong adhesion with cytocompatibility have yet to be developed. In this study, we explored the production of adhesives based on protein-engineered polymers bioinspired by the sequence of elastin (i.e., elastin-like recombinamers, ELRs). We hypothesized that the combination of polyphenols (i.e., tannic acid, TA) and ELRs would produce an adhesive coacervate (ELR+TA), as reported for other protein polymers such as silk fibroin (SF). Notably, the adhesion of ELR alone surpassed that of ELR+TA. Indeed, ELR alone achieved adhesive strengths of 88.8 ± 33.2 kPa and 17.0 ± 2.0 kPa on porcine bone and skin tissues, respectively. This surprising result led us to explore a multicomponent bioadhesive to encompass the complementary roles of elastin (mimicked here by ELR) and silk fibroin (SF), and subsequently mirror more closely the multicomponent nature of the extracellular matrix. Tensile testing showed that ELR+SF achieved an adhesive strength of 123.3 ± 60.2 kPa on porcine bone and excellent cytocompatibility. To express this in a more visual and intuitive way, a small surface of only 2.5 cm2 was able to lift at least 2 kg of weight. This opens the door for further studies focusing on the ability of protein-engineered polymers to adhere to biological tissues without further chemical modification for applications in tissue engineering.

5 April 2019 in Biomedical Materials
Verified
Journal Article
Open access
PDF file
LNLaura Nehrenheim
Laura Nehrenheim
SRSilja Raschke
Silja Raschke
ASAnja Stefanski
Anja Stefanski
Mareike BarthMareike Barth
Mareike Barth
JSJessica Isabel Selig
Jessica Isabel Selig
Payam AkhyariPayam Akhyari
Payam Akhyari
Calcific aortic valve disease (CAVD) is the most common acquired heart valve disease with complex underlying pathomechanisms that are yet not fully understood. Three-dimensional (3D) cell culture models as opposed to conventional two-dimensional (2D) techniques may reveal new aspects of CAVD and serve as a transitional platform between conventional 2D cell culture and in vivo experiments. Here we report on fabrication and characterization of a novel 3D hydrogel derived from cell-free native aortic valves. A detailed analysis containing protein composition, rheological behavior, cytotoxic and proliferative effects as well as results of 3D cell culture experiments are presented. Moreover, this aortic valve derived hydrogel (AVdH) is compared to commercially available biological extracellular matrix (ECM) components to evaluate and classify AVdH with respect to other currently used ECM solutions, i.e. Collagen type I and Matrigel®. On the biochemical level, a complex composition of native proteins was detected. Using different techniques, including mass spectrometry with Gene Ontology network and enrichment analysis, different fundamental biological functions of AVdH were identified, including peptidase-, peptidase inhibitor-, growth- and binding activity. No cytotoxic effects were detected and AVdH showed positive effects on cell growth and proliferation in vitro when compared to Collagen type I and Matrigel®. These results suggest AVdH as an organotypic ECM supporting sophisticated 3D cell culture model studies, while mimicking the native environment of the aortic valve to a greater level for enhanced in vitro analyses.