Igor Pušnik

Prof. Dr. Igor Pušnik

Faculty of Electrical Engineering, University of Ljubljana, SI-1000 Ljubljana, Slovenia

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2005 in Physiological Measurement
Verified
Journal Article
Closed access
Igor PušnikIgor Pušnik
Igor Pušnik
JDJanko Drnovšek
Janko Drnovšek
Infrared ear thermometers (IRETs) are extensively used for measuring the temperature of a human body. For accurate measurements with IRETs they have to be calibrated regularly with an appropriate and traceable calibration system. Such systems are neither widely available nor are there many competent (accredited) laboratories which can provide traceability for IRETs. This paper describes some important influential parameters in the calibration and use of IRETs, which were observed during the extensive research on IRETs and have not been reported in the literature yet. IRET readings, and consequently also their most important metrological characteristics, accuracy and uncertainty of measurement, depend on these influential parameters. According to our findings, we would like to warn users of medical radiation thermometers, not only IRETs but also forehead thermometers and infrared temperature scanning systems, that they should be extremely careful in selection, maintenance and use of medical radiation thermometers. Measurement accuracy, as it is required by several technical standards, is hard to achieve with the majority of currently available medical radiation thermometers.

1 January 2011 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
GGGoran Grgić
Goran Grgić
Igor PušnikIgor Pušnik
Igor Pušnik

16 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Igor PušnikIgor Pušnik
Igor Pušnik
GGGregor Geršak
Gregor Geršak
In numerous applications, including current body temperature monitoring in viral pandemic management, thermal imaging cameras are used for quantitative measurements. These require determination of the measurement accuracy (error) and its traceability (measurement uncertainty). Within error estimation, the size-of-source effect (SSE) is an important error source. The SSE is the relation between the physical size of a target and the instrument’s nominal target size. This study presents a direct evaluation of the error due to the SSE. A stable and uniform temperature, generated by blackbodies, was measured by a high-quality thermal imager. To limit the generated radiation, custom-made blocking tiles with different apertures were used. Effects of aperture shapes and positions, camera-target distances and temperature levels on the error were investigated. The study findings suggest that due to the SSE the measured temperatures are too low, especially at longer camera-target distances. The SSE error depends on the number of pixels available and included into the region of interest, for which the accurate measurement is about to be performed. For an accurate temperature measurement, an array of at least 10 × 10 pixels should be exposed to the observed target radiation, while 3 × 3 central pixel area should be included in the temperature calculation.

16 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
VMVid Mlačnik
Vid Mlačnik
Igor PušnikIgor Pušnik
Igor Pušnik
Current process of calibrating radiation thermometers, including thermal imagers, relies on measurement comparison with the temperature of a black body at a set distance. Over time, errors have been detected in calibrations of some radiation thermometers, which were correlated with moisture levels. In this study, effects of atmospheric air on thermal transmission were evaluated by the means of simulations using best available resources of the corresponding datasets. Sources of spectral transmissivity of air were listed, and transmissivity data was obtained from the HITRAN molecular absorption database. Transmissivity data of molecular species was compiled for usual atmospheric composition, including naturally occurring isotopologs. Final influence of spectral transmissivity was evaluated for spectral sensitivities of radiation thermometers in use, and total transmissivity and expected errors were presented for variable humidity and measured temperature. Results reveal that spectral range of measurements greatly influences susceptibility of instruments to atmospheric interference. In particular, great influence on measurements is evident for the high-temperature radiation pyrometer in the spectral range of 2–2.7 µm, which is in use in our laboratory as a traceable reference for high-temperature calibrations. Regarding the calibration process, a requirement arose for matching the humidity parameters during the temperature reference transfer to the lower tiers in the chain of traceability. Narrowing of the permitted range of humidity during the calibration, monitoring, and listing of atmospheric parameters in calibration certificates is necessary, for at least this thermometer and possibly for other thermometers as well.

1 November 1998 in Measurement Science and Technology
Verified
Journal Article
Closed access
JDJanko Drnovsek
Janko Drnovsek
Igor PušnikIgor Pušnik
Igor Pušnik
JBJovan Bojkovski
Jovan Bojkovski

15 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VMVid Mlačnik
Vid Mlačnik
Igor PušnikIgor Pušnik
Igor Pušnik
Despite great technical capabilities, the theory of non-contact temperature measurement is usually not fully applicable to the use of measuring instruments in practice. While black body calibrations and black body radiation thermometry (BBRT) are in practice well established and easy to accomplish, this calibration protocol is never fully applicable to measurements of real objects under real conditions. Currently, the best approximation to real-world radiation thermometry is grey body radiation thermometry (GBRT), which is supported by most measuring instruments to date. Nevertheless, the metrological requirements necessitate traceability; therefore, real body radiation thermometry (RBRT) method is required for temperature measurements of real bodies. This article documents the current state of temperature calculation algorithms for radiation thermometers and the creation of a traceable model for radiation thermometry of real bodies that uses an inverse model of the system of measurement to compensate for the loss of data caused by spectral integration, which occurs when thermal radiation is absorbed on the active surface of the sensor. To solve this problem, a hybrid model is proposed in which the spectral input parameters are converted to scalar inputs of a traditional scalar inverse model for GBRT. The method for calculating effective parameters, which corresponds to a system of measurement, is proposed and verified with the theoretical simulation model of non-contact thermometry. The sum of effective instrumental parameters is presented for different temperatures to show that the rule of GBRT, according to which the sum of instrumental emissivity and instrumental reflectivity is equal to 1, does not apply to RBRT. Using the derived models of radiation thermometry, the uncertainty of radiation thermometry due to the uncertainty of spectral emissivity was analysed by simulated worst-case measurements through temperature ranges of various radiation thermometers. This newly developed model for RBRT with known uncertainty of measurement enables traceable measurements using radiation thermometry under any conditions.