The paper presents a novel measuring system for detecting air gap anomalies in direct-drive electrical motors. The air gap anomalies can be of different types of eccentricity which may in extreme cases result in a mechanical rub between the stator and rotor, potentially leading to a motor breakdown. A novel measuring method is proposed using a sensory system integrated in a motor air gap to measure its width directly either in a static or dynamic state. It uses an optical sensory system to measure reflection of the infrared radiation between the rotor and stator. The method is validated by using a parallel measuring system employing an analogue Hall sensory system that measures the change in the magnetic-flux density. The two measuring systems are calibrated by comparing them to a reference laboratory measuring system consisting of a camera and lenses. The calibration is performed in a laboratory in a motor static state within one mechanical rotation cycle of the rotor. Using different calibration techniques, the optimal system accuracy, with a maximum permissible error of 0.15 mm is obtained, in the measuring range between 0 mm and 2 mm. It covers most applications of the direct-drive electrical motors. The new measuring method is validated by using an experimental set-up consisting of the presented optical sensory system and validation system an analogue Hall integrated on a testing platform (Smart Fortwo car).
6 June 2008 in International Journal of Thermophysics
In-wheel motors (IWMs) as a crucial component of an electric vehicle need to be tested at the end of the production line, at service intervals, and during motor design validation. This article presents an improved synthetic loading (SL) method for the rapid characterization of the IWMs. The proposed method emulates mechanical loading at a specific operating point by current harmonic injection. We introduce a novel algorithm for the current reference setting that is based on the manufacturer’s motor design data and accounts for the motor’s nonlinearities. Also, the method features a trapezoidal reference instead of a sinusoidal, which lowers the instantaneous peak current of the converter and, thereby, increases the attainable torque–speed range. The performance of the proposed SL method is comparable to the classic back-to-back (BB) testing method, which is confirmed by the theoretical analysis, simulations, and experimental results. The difference in motor efficiency measured with the BB and the improved SL method is smaller than 1% in most operating points. The proposed method offers considerable time and cost savings for the manufacturer—eliminating the mechanical coupling/decoupling operation—and can be applied to surface-mounted permanent magnet synchronous machines in general.
1 November 1998 in Measurement Science and Technology
This article describes the interlaboratory comparison (ILC) of meteorological and hydrological calibration laboratories in the field of temperature (−30° to 40°C), humidity (10%–95% RH at room temperature), and pressure (800–1100 hPa). The ILC was organized by the World Meteorological Organization (WMO) Regional Instrument Centre (RIC) at the Slovenian Environment Agency and University of Ljubljana, Faculty of Electrical Engineering, Laboratory of Metrology and Quality as an accredited interlaboratory comparison (proficiency testing) provider according to the ISO/IEC 17043:2010 standard. The ILC was organized in the target area of WMO Regional Association VI (Europe). The protocol and procedure for ILC were developed within European Metrology Research Project (EMRP) MetoMet2. The participants used their standardized procedures for calibration. Because of the large number of participating laboratories (18) from 17 countries, the ILC was organized in two loops, which were linked via four linking laboratories and evaluated using the En number. The equipment used in both loops exhibited stability and uncertainty, which enabled evaluation of the laboratories’ capabilities. The article presents the data processing, the linkage procedure, and the main results for all three categories (temperature, humidity, and pressure). It was observed that some of the laboratories had unusually low uncertainties. From the metrological point of view, the authors present some comments and suggestions to the laboratories, the results of which differ from the reference ones. The conclusions can help also other meteorological laboratories and organizations that did not participate in the ILC with their everyday work.