Janko Drnovšek

Janko Drnovšek

Auto-generated profile, based on publicly available information

Janko Drnovšek

University of Ljubljana

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2009 in Accreditation and Quality Assurance
Verified
Journal Article
Closed access
PDF file
GBGaber Begeš
Gaber Begeš
JDJanko Drnovsek
Janko Drnovsek
LPLeslie R. Pendrill
Leslie R. Pendrill

16 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JKJure Kranjec
Jure Kranjec
SBSamo Beguš
Samo Beguš
GGGregor Geršak
Gregor Geršak
MŠMatjaž Šinkovec
Matjaž Šinkovec
JDJanko Drnovšek
Janko Drnovšek
DHDomen Hudoklin
Domen Hudoklin
The object of the proposed paper is to design and analyze the performance of a non-contact heart rate variability (HRV) measuring device based on ultrasound transducers. The rationale behind non-contact HRV measurement is the goal of obtaining a means of long term monitoring of a patient’s heart performance. Due to its complexity as a non-contact measuring device, influential physical quantities, error source and other perturbations were thoroughly investigated. For medical purposes it is of utmost importance to define the target uncertainty of a measuring method from the side of physicians, while it is the role of scientists to realistically evaluate all uncertainty contributions. Within this paper we present a novelty method of non-contact HRV measurement based on ultrasound transducers operating at two frequencies simultaneously. We report laboratory results and clinical evaluations are given for healthy subjects as well as patients with known heart conditions. Furthermore, laboratory tests were conducted on subjects during a relaxation period, and after 1 min physical activity

1 November 1998 in Measurement Science and Technology
Verified
Journal Article
Closed access
JDJanko Drnovsek
Janko Drnovsek
Igor PušnikIgor Pušnik
Igor Pušnik
JBJovan Bojkovski
Jovan Bojkovski

1 February 2019 in Journal of Atmospheric and Oceanic Technology
Verified
Journal Article
Closed access
JBJovan Bojkovski
Jovan Bojkovski
JDJanko Drnovšek
Janko Drnovšek
DGDrago Groselj
Drago Groselj
JKJoško Knez
Joško Knez
GBGaber Begeš
Gaber Begeš
This article describes the interlaboratory comparison (ILC) of meteorological and hydrological calibration laboratories in the field of temperature (−30° to 40°C), humidity (10%–95% RH at room temperature), and pressure (800–1100 hPa). The ILC was organized by the World Meteorological Organization (WMO) Regional Instrument Centre (RIC) at the Slovenian Environment Agency and University of Ljubljana, Faculty of Electrical Engineering, Laboratory of Metrology and Quality as an accredited interlaboratory comparison (proficiency testing) provider according to the ISO/IEC 17043:2010 standard. The ILC was organized in the target area of WMO Regional Association VI (Europe). The protocol and procedure for ILC were developed within European Metrology Research Project (EMRP) MetoMet2. The participants used their standardized procedures for calibration. Because of the large number of participating laboratories (18) from 17 countries, the ILC was organized in two loops, which were linked via four linking laboratories and evaluated using the En number. The equipment used in both loops exhibited stability and uncertainty, which enabled evaluation of the laboratories’ capabilities. The article presents the data processing, the linkage procedure, and the main results for all three categories (temperature, humidity, and pressure). It was observed that some of the laboratories had unusually low uncertainties. From the metrological point of view, the authors present some comments and suggestions to the laboratories, the results of which differ from the reference ones. The conclusions can help also other meteorological laboratories and organizations that did not participate in the ILC with their everyday work.

25 September 2009 in Instrumentation Science & Technology
Verified
Journal Article
Closed access
AMAndraž Miklavec
Andraž Miklavec
VBValentin Batagelj
Valentin Batagelj
JBJovan Bojkovski
Jovan Bojkovski
Igor PušnikIgor Pušnik
Igor Pušnik
JDJanko Drnovšek
Janko Drnovšek
Accurate and repeatable spatial positioning of measurement equipment is required in many laboratory experiments and measurement procedures. Although such mechanical manipulation can often be performed manually, by using special equipment such as different mechanical tripods, an automated spatial positioning system offers several advantages, such as higher accuracy and repeatability, reduced operator workload, and possibility to implement more complex measurement procedures. Many adequate spatial positioning systems are commercially available, but our aim was to produce a high quality, low cost, and measurement oriented solution, with special emphasis on correct evaluation of all metrological parameters.

10 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RTRok Tavčar
Rok Tavčar
JDJanko Drnovšek
Janko Drnovšek
JBJovan Bojkovski
Jovan Bojkovski
SBSamo Beguš
Samo Beguš
When designing a single tube practical acoustic thermometer (PAT), certain considerations should be addressed for optimal performance. This paper is concerned with the main issues involved in building a reliable PAT. It has to be emphasised that a PAT measures the ratio of the time delay between the single temperature calibration point (ice point) and any other temperature. Here, we present different models of the speed of sound in tubes, including the effects of real gases and an error analysis of the most accurate model with a Monte Carlo simulation. Additionally, we introduce the problem of acoustic signal overlap and some possible solutions, one of which is acoustic signal cancellation, which aims to eliminate the unwanted parts of an acoustic signal, and another is to optimize the tube length for the parameters of the gas used and specific temperature range.