Belma Imamović

Prof. Dr. Belma Imamović

Department for Pharmaceutical Analysis
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2004 in Biomolecules and Biomedicine
Verified
Journal Article
Open access
PDF file
BNBranko Nikolin
Branko Nikolin
Belma ImamovićBelma Imamović
Belma Imamović
SMSaira Medanhodžić-Vuk
Saira Medanhodžić-Vuk
MSMiroslav Sober
Miroslav Sober
In testing the pre-sale procedure the marketing of drugs and their control in the last ten years, high performance liquid chromatographyreplaced numerous spectroscopic methods and gas chromatography in the quantitative and qualitative analysis. In the first period of HPLC application it was thought that it would become a complementary method of gas chromatography, however, today it has nearly completely replaced gas chromatography in pharmaceutical analysis. The application of the liquid mobile phase with the possibility of transformation of mobilized polarity during chromatography and all other modifications of mobile phase depending upon the characteristics of substance which are being tested, is a great advantage in the process of separation in comparison to other methods. The greater choice of stationary phase is the next factor which enables realization of good separation. The separation line is connected to specific and sensitive detector systems, spectrafluorimeter, diode detector, electrochemical detector as other hyphernated systems HPLC-MS and HPLC-NMR, are the basic elements on which is based such wide and effective application of the HPLC method. The purpose high performance liquid chromatography(HPLC) analysis of any drugs is to confirm the identity of a drug and provide quantitative results and also to monitor the progress of the therapy of a disease.1) Measuring presented on the Fig. 1. is chromatogram obtained for the plasma of depressed patients 12 h before oral administration of dexamethasone. It may also be used to further our understanding of the normal and disease process in the human body trough biomedical and therapeutically research during investigation before of the drugs registration. The analyses of drugs and metabolites in biological fluids, particularly plasma, serum or urine is one of the most demanding but one of the most common uses of high performance of liquid chromatography. Blood, plasma or serum contains numerous endogenous compounds often present in concentrations much greater than those of analyte. Analiyte concentrations are often low, and in the case of drugs, the endogenous compounds are sometimes structurally very similar to the drug to be measured. The binding of drugs to the plasma protein also may occur which decreases the amount of free compound that is measured. To undertake the analyses of drugs and metabolites in body fluids the analyst is facet with several problems. The first problem is due to the complex nature of the body fluid, the drugs must be isolated by an extraction technique, which ideally should provide a relatively clean extract, and the separation system must be capable of resolving the drugs of interest from co extractives. All mentioned when we are using high performance liquid chromatography require good selections of detectors, good stationary phase, eluents and adequate program during separation. UV/VIS detector is the most versatile detector used in high performance liquid chromatography it is not always ideal since it is lack of specificity means high resolution of the analyte that may be required. UV detection is preferred since it offers excellent linearity and rapid quantitative analyses can be performed against a single standard of the drug being determined. Diode array and rapid scanning detector are useful for peak identification and monitoring peak purity but they are somewhat less sensitive then single wavelength detectors. In liquid chromatography some components may have a poor UV chromophores if UV detection is being used or be completely retained on the liquid chromatography column. Fluorescence and electrochemical detector are not only considerably more sensitive towed appropriate analytes but also more selective than UV detectors for many compounds. If at all possible fluorescence detectors are sensitive, stable, selective and easy to operate. It is selectivity shows itself in the lack of frontal components observed in plasma extract whereas electrochemical detection is nearly always associated with a major frontal peak than tails considerably. To date, the most sensitive method has been the reductive electrochemical detection and giving the excellent results in the investigation on some classes of drugs. Several high performance liquid chromatography oxidative electrochemical methods have been developed for the analyses of drugs and metabolites in body fluids. Mass spectrometer as specific detector with all variation of ionisation and interface (thermo spray, moving belt etc. ) or liquid chromatography-tandem mass spectrometry2,3,4,5). NMR as selective and specific detector in high performance liquid chromatography today is also in used. The development of a non-aqueous eluent for ion-exchange separation on silica has provided an excellent system which, when used in conjugation with an electrochemical detector, permits the analyses of an extensive range of especially basic drugs and metabolites. New packing materials such as polymeric, base deactivated silica's, pyrolysed carbon and the internal surface packing should offer the improved stability and higher efficiencies for certain classes of the compounds such as basic drugs. Microbore columns should become more accepted since they offer not only improved sensitivity but also a lower solvent consumption and consequently the reduced needs to dispose of noxious solvents. Many analyses of basic drugs are still performed by the same method of the ion-exchange chromatography on unmodified silica columns with an eluent buffered to about pH 9. Neutral or weakly acidic drugs for instance barbiturates can be chromatographed on a reversed phase system whilst acidic drugs for example paracetamol, cannabis are separated either by ion suppression or ion-pair chromatography on a reversed-phase packing material. In micelar liquid chromatography micelar mobile phases in reversed-phase instead of conventional hydro organic mobile phase is used. In micelar liquid...

14 March 2022 in Molecules
Verified
Journal Article
Open access
PDF file
Belma ImamovićBelma Imamović
Belma Imamović
Polonca TrebsePolonca Trebse
Polonca Trebse
EOElma Omeragic
Elma Omeragic
Ervina BečićErvina Bečić
Ervina Bečić
APAndrej Pečet
Andrej Pečet
Mirza DedićMirza Dedić
Mirza Dedić
Benzophenone (BP) type UV filters are common environmental contaminants that are posing a growing health concern due to their increasing presence in water. Different studies have evidenced the presence of benzophenones (BP, BP-1, BP-2, BP-3, BP-4, BP-9, HPB) in several environmental matrices, indicating that conventional technologies of water treatment are not able to remove them. It has also been reported that these compounds could be associated with endocrine-disrupting activities, genotoxicity, and reproductive toxicity. This review focuses on the degradation kinetics and mechanisms of benzophenone-type UV filters and their degradation products (DPs) under UV and solar irradiation and in UV-based advanced oxidation processes (AOPs) such as UV/H2O2, UV/persulfate, and the Fenton process. The effects of various operating parameters, such as UV irradiation including initial concentrations of H2O2, persulfate, and Fe2+, on the degradation of tested benzophenones from aqueous matrices, and conditions that allow higher degradation rates to be achieved are presented. Application of nanoparticles such as TiO2, PbO/TiO2, and Sb2O3/TiO2 for the photocatalytic degradation of benzophenone-type UV filters was included in this review.

11 May 2023 in Environmental Science and Pollution Research
Verified
Journal Article
Open access
PDF file
FHFallah Hashemi
Fallah Hashemi
Lori HoepnerLori Hoepner
Lori Hoepner
FHFarahnaz Soleimani Hamidinejad
Farahnaz Soleimani Hamidinejad
Daniela HaluzaDaniela Haluza
Daniela Haluza
SASima Afrashteh
Sima Afrashteh
MHMohammad Hoseini
Mohammad Hoseini
COVID-19 has affected all aspects of human life so far. From the outset of the pandemic, preventing the spread of COVID-19 through the observance of health protocols, especially the use of sanitizers and disinfectants was given more attention. Despite the effectiveness of disinfection chemicals in controlling and preventing COVID-19, there are critical concerns about their adverse effects on human health. This study aims to assess the health effects of sanitizers and disinfectants on a global scale. A total of 91,056 participants from 154 countries participated in this cross-sectional study. Information on the use of sanitizers and disinfectants and health was collected using an electronic questionnaire, which was translated into 26 languages via web-based platforms. The findings of this study suggest that detergents, alcohol-based substances, and chlorinated compounds emerged as the most prevalent chemical agents compared to other sanitizers and disinfectants examined. Most frequently reported health issues include skin effects and respiratory effects. The Chi-square test showed a significant association between chlorinated compounds (sodium hypochlorite and per-chlorine) with all possible health effects under investigation (p-value <0.001). Examination of risk factors based on multivariate logistic regression analysis showed that alcohols and alcohols-based materials were associated with skin effects (OR, 1.98; 95%CI, 1.87–2.09), per-chlorine was associated with eye effects (OR, 1.83; 95%CI, 1.74–1.93), and highly likely with itching and throat irritation (OR, 2.00; 95%CI, 1.90–2.11). Furthermore, formaldehyde was associated with a higher prevalence of neurological effects (OR, 2.17; 95%CI, 1.92–2.44). Furthermore, formaldehyde was associated with a higher prevalence of neurological effects (OR, 2.17; 95%CI, 1.92–2.44). The use of sodium hypochlorite and per-chlorine also had a high chance of having respiratory effects. The findings of the current study suggest that health authorities need to implement more awareness programs about the side effects of using sanitizers and disinfectants during viral epidemics especially when they are used or overused.
1

13 September 2011 in Pigment & Resin Technology
Verified
Journal Article
Closed access
EBErvina Bečić
Ervina Bečić
MŠMiroslav Šober
Miroslav Šober
Belma ImamovićBelma Imamović
Belma Imamović
DZDavorka Završnik
Davorka Završnik
SŠSelma Špirtović‐Halilović
Selma Špirtović‐Halilović
Purpose: The purpose of this paper is to test absorption characteristics of some newly synthesised 4‐hidroxycoumarins, containing phenyl‐prop‐2‐enoyl group at the 3‐position. Change in spectral characteristics in solvents of different polarity (chloroform and acetonitrile) was followed in regard to the influence of the substitution at the phenyl ring and influence of concentration H+ ions. Effectiveness of tested substances was compared with well‐known UV absorbers such as benzophenone‐3 and butyl methoxydibenzoylmethane (BMDM).Design/methodology/approach: All the tested substances were dissolved in chloroform and acetonitrile, with 10‐3 mmol concentration range. The pH was adjusted using 0.1 mol/l HCl, glacial acetic acid, 0.1 mol/l NaOH (aqueous solution) and 0.1 mol/l NaOH (methanolic solution). Spectrophotometric measurement was recorded in the range of 200‐800 nm, using 1‐cm quartz cells.Findings: The tested 4‐hydroxycoumarin derivatives showed good UV absorption properties in the range 280‐380 nm. Substitution on the phenyl ring changes the shape of the absorption maxima. The changes depend on the properties of the substituent as well as the acidity of the solution.Research limitations/implications: Introducing an electron‐donating substituent on the phenyl‐prop‐2‐enoyl group can shift absorption maximums to longer wavelength. In addition, the variation in substituents on the synthesised substances and pH of the solution could also be studied.Practical implications: The new compounds showed good UV absorption, making them potential candidates for many applications. The practical importance of the tested substances are derived from their stability, relatively easy synthesis and good UV absorption properties.Originality/value: The paper shows that the tested coumarins derivatives were new compounds with good UV absorption properties, making them good UV absorbers of commercial potential. The tested coumarins showed good UV absorption properties in the range 280‐380 nm, making them potential candidates for many applications.

6 July 2016 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
ASAida Sapcanin
Aida Sapcanin
MCMirsada Cakal
Mirsada Cakal
Belma ImamovićBelma Imamović
Belma Imamović
MSMirsada Salihovic
Mirsada Salihovic
EPEkrem Pehlic
Ekrem Pehlic
GJGordan Jancan
Gordan Jancan

3 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Belma ImamovićBelma Imamović
Belma Imamović
Irmela IvazovićIrmela Ivazović
Irmela Ivazović
Amra AlispahicAmra Alispahic
Amra Alispahic
Ervina BečićErvina Bečić
Ervina Bečić
Mirza DedićMirza Dedić
Mirza Dedić
Armina DacićArmina Dacić
Armina Dacić
Anti-aging cosmetics are often sought after in order to slow down the aging process. Free radicals are one of the main causes of skin aging, and therefore antioxidants are used in anti-aging cosmetics. The aim of this study was to investigate which method is the most suitable for determining the antioxidant capacity of these products. Having samples extracted, the antioxidant capacity of the extracts obtained was determined by the following spectrophotometric methods: DPPH, Folin-Ciocalteu, FRAP, the ABTS method and the ferroion chelation method with ferrosine. The antioxidant capacity of the samples varied depending on the extract type and the method used. DPPH and ferroion chelation measurements with ferrosine were carried out in the part of the spectrum where plant pigments absorb. These pigments are often found in anti-aging products affecting these methods measurement results. The Folin-Ciocalteu method is suitable for researching the antioxidant capacity of hydrophilic extracts, but not lipophilic ones, where turbidity and the formation of a gelled ring occur. The FRAP method revealed similar results for all the samples and proved to be less sensitive than the others. The ABTS method for both types of extracts has proven to be the most suitable and sensitive method for determining the antioxidant capacity of anti-aging products.