Nowadays, relevant data collected from hospital buildings remain insufficient because hospital buildings often have stricter environmental requirements resulting in more limited data access than other building types. Additionally, existing window-opening behavior models were mostly developed and validated using data measured from the experimental building itself. Hence, their accuracy is only assessed by the algorithm’s evaluation index, which limits the model’s applicability, given that it is not tested by the actual cases nor cross-verified with other buildings. Based on the aforementioned issues, this study analyzes the window-opening behavior of doctors and patients in spring in a maternity hospital in Beijing and develops behavioral models using logistic regression. The results show that the room often has opened windows in spring when the outdoor temperature exceeds 20 °C. Moreover, the ward windows’ use frequency is more than 10 times higher than those of doctors’ office. The window-opening behavior in wards is more susceptible to the influence of outdoor temperature, while in the doctors’ office, more attention is paid to indoor air quality. Finally, by embedding the logistic regression model of each room into the EnergyPlus software to simulate the CO2 concentration of the room, it was found that the model has better applicability than the fixed schedule model. However, by performing cross-validation with different building types, it was found that, due to the particularity of doctors’ offices, the models developed for other building types cannot accurately reproduce the window-opening behavior of doctors. Therefore, more data are still needed to better understand window usage in hospital buildings and support the future building performance simulations of hospital buildings.
Although much research is being conducted on the characteristics of PM2.5 and PM10 at subway stations, there is no research focusing on a complex subway transfer station. In this paper, the characteristics of PM2.5 and PM10 at transfer stations are studied. For comparison, monitoring is performed under different outside conditions at four different transfer stations in the non-peak period during March 2018. The concentrations of PM2.5 and PM10 on the platform in the transfer stations is approximately 10 μg/m3 lower than in the non-transfer station, when outside PM2.5 is lower than 150 μg/m3. However, the ratio of PM2.5 to PM10 at the transfer stations (lowest: 78.1%) is higher than at the non-transfer station (lowest: 61.2%), indicating that the PM10 content differs from the non-transfer station. In a transfer station with the same depth, the PM concentration is the same or similar. In addition, the concentration of PM2.5 at subway stations has a strong correlation with the outside environment (R2 = 0.897), which indicates that an outside condition is important for the subway environment.
As the popularity of fresh air systems (FAS) in residential buildings increases, exploring the behavioral characteristics of their use can help to provide a comprehensive understanding of the potential for demand flexibility in residential buildings. However, few studies in the past have focused on the personalized usage behavior of FAS. To fill this gap, this study proposes a method based on data mining techniques to reveal the behavioral patterns of FAS usage and the motivations behind them, including motivational patterns, operation duration patterns, and human–machine interaction patterns, for 13 households in Beijing. The simultaneously obtained behavioral patterns, in turn, form the basis of association rules, which can classify FAS usage behavior into two typical residential user profiles containing user behavioral characteristics. This study can not only provide more accurate assumptions and inputs for behavioral stochastic models but also provide data support for the development and optimization of demand response strategies.