xinru wang

Dr. xinru wang

Tianjin Commerce University, Mechanical engineering college

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2023 in Heliyon
Verified
Journal Article
Open access
XWxinru wang
xinru wang
LXLiang Xia
Liang Xia
FPFei Pei
Fei Pei
ZWZU WANG
ZU WANG
YLYiqiao Liu
Yiqiao Liu
SPSong Pan
Song Pan
Particulate matter (PM2.5, PM10) in urban subway stations can significantly impact passengers' health. The particle concentration in subway stations is influenced by many factors. However, few existing studies have explored the impact of environmental control systems in-depth, especially under different outdoor pollution conditions. To address this research gap, this study focused on measuring and comparing the characteristics of PM2.5 and PM10 at subway stations with three control systems (open, closed, and screen door) under varying pollution conditions in Beijing. Particle concentrations from platforms, carriages, and outdoors were monitored and analyzed using statistical methods. The results showed that the particle concentration in the closed system was generally 20–40 μg/m3 higher than that in the screen system at the platform, which might be attributed to the piston wind, as the air from the tunnel with a lot of dirt. The pollution in the carriage was more severe for the open system than that of the screen system. The PM2.5/PM10 ratio in the carriage was 91%, 90%, and 83.84% for the closed, open, and screen systems, respectively. This indicates that the screen door could reduce the particle concentration in the platform to 10%–50%. The particle concentration varied among subway stations with different environmental control systems, suggesting that the prevention and control strategies for particulate matter pollution should be different for stations with different systems.

8 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YYyindong yuan
yindong yuan
PSPan Song
Pan Song
TWtongzhao wang
tongzhao wang
LXLiang Xia
Liang Xia
YLYiqiao Liu
Yiqiao Liu
TWTian Wang
Tian Wang
Catalytic combustion can effectively and cleanly convert the chemical energy of fossil fuels into infrared radiation energy. However, there is little research on the use of this technology to cure powder coatings. Therefore, catalytic infrared heating equipment based on a Pt/Al2O3 noble metal catalyst was designed, constructed, and tested in this study. The optimal curing parameters for the catalytic infrared curing process for powder coatings were determined via experiments at 220 °C for 3 min and 230 °C for 2 min. As the curing temperature increased and the curing time increased, the mechanical properties of the coating were found to improve. However, the gloss of the coating was reduced and the color darkened. A one-dimensional heat transfer model was developed to investigate the heat transfer process for powder coatings. This study introduced an internal heat source for the first time, and the heat transfer process for polyester-based powder coatings with different substrate thicknesses was numerically simulated. The numerical simulations demonstrated that the efficiency of the heat transfer between the catalytic infrared gas supply and the coating surface was 0.4. When the substrate thickness was 1 mm, the coating was most rapidly cured at 230 °C. When the substrate thickness was ≥2 mm, the most rapid curing occurred at 220 °C.

15 August 2025 in International Journal of Food Microbiology
Verified
Journal Article
Closed access
ZWZhiqiang Wang
Zhiqiang Wang
SGSaiwei Ge
Saiwei Ge
HLHaiyang Li
Haiyang Li
WXWei Xiao
Wei Xiao
XWxinru wang
xinru wang
JPJingjing Pei
Jingjing Pei

28 January 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
XWxinru wang
xinru wang
LXLiang Xia
Liang Xia
FPFei Pei
Fei Pei
LCLi Chang
Li Chang
Chong Wen TongChong Wen Tong
Chong Wen Tong
PSPan Song
Pan Song
Although much research is being conducted on the characteristics of PM2.5 and PM10 at subway stations, there is no research focusing on a complex subway transfer station. In this paper, the characteristics of PM2.5 and PM10 at transfer stations are studied. For comparison, monitoring is performed under different outside conditions at four different transfer stations in the non-peak period during March 2018. The concentrations of PM2.5 and PM10 on the platform in the transfer stations is approximately 10 μg/m3 lower than in the non-transfer station, when outside PM2.5 is lower than 150 μg/m3. However, the ratio of PM2.5 to PM10 at the transfer stations (lowest: 78.1%) is higher than at the non-transfer station (lowest: 61.2%), indicating that the PM10 content differs from the non-transfer station. In a transfer station with the same depth, the PM concentration is the same or similar. In addition, the concentration of PM2.5 at subway stations has a strong correlation with the outside environment (R2 = 0.897), which indicates that an outside condition is important for the subway environment.

6 October 2026 in Energies
Verified
Journal Article
Open access
PDF file
YCYing Cui
Ying Cui
Chong Wen TongChong Wen Tong
Chong Wen Tong
MVMahendra Varman
Mahendra Varman
XWxinru wang
xinru wang
YLYiqiao Liu
Yiqiao Liu
PSPan Song
Pan Song
Ground source heat pump (GSHP) systems play a pivotal role in the decarbonization of heating, ventilation, and air conditioning systems. However, their long-term performance depends heavily on operational control strategies capable of addressing system dynamics, varying load conditions, and the increasing integration with renewable and distributed energy resources. Data-driven methods have emerged as promising approaches for improving the operational flexibility, efficiency, and sustainability of GSHP systems. Existing review studies mainly focus on predictive modeling and provide limited systematic analysis of the interactions among predictive modeling, control, and optimization, particularly in hybrid and networked energy systems. This review shows recent advances in data-driven approaches for GSHP operational control. The reviewed studies demonstrate that data-driven control strategies can improve operational performance and enable real-time decision-making under dynamic conditions, particularly when predictive models are integrated with first-principles models and optimization algorithms. Beyond conventional standalone applications, this review highlights the transition toward hybrid GSHP configurations and integrated energy systems, including fifth-generation district heating and cooling networks. Within these systems, operational objectives shift from maintaining local ground thermal balance and maximizing equipment efficiency to achieving coordinated energy exchange, load flexibility, economic performance, and carbon-aware network operation. Despite substantial methodological advances, challenges related to data quality, boundary uncertainty, model transferability, and computational scalability continue to limit large-scale deployment of data-driven control strategies. Finally, future directions for developing intelligent, interpretable, and scalable data-driven control frameworks for next-generation low-carbon buildings and district energy systems are outlined.

10 September 2021 in Research Square
Verified
Preprint
Open access
PDF file
XWxinru wang
xinru wang
LXLiang Xia
Liang Xia
FPFei Pei
Fei Pei
ZWzu Wang
zu Wang
YLYiqiao Liu
Yiqiao Liu
SPSong Pan
Song Pan
The characteristics of inhalable particulate matter (PM2.5, PM10) in urban subway stations can have a major impact on passengers’ health. Existing research largely fails to focus on different environmental control systems and there are few studies focused on different pollution conditions. This study therefore focused on measuring and comparing the characteristics of PM2.5 and PM10 at subway stations with three control systems in Beijing different pollution conditions. Stations including three types of control system (open, closed and screen door) and outside were monitored and analyzed using a general linear model. The concentration of PM2.5 and PM10 at different locations, such as on platforms, in carriages and in working areas, was compared and analyzed under different external pollution conditions. The results show that at different environment control systems the characteristics of PM2.5 and PM10 are different. The concentrations of particles in closed system are generally higher than screen system at platform. While the pollution in carriage is heavier for open system than that of screen system. The PM2.5/PM10 ratio was 91%, 90% and 83.84% at closed, open and screen system, respectively. While, the PM2.5 and PM10 levels inside the stations were strongly correlated with the outdoor conditions regardless of the environmental control system. This is the first study to show the PM concentration characteristics for different subway environmental control systems. As such, it provides a solid foundation for air clean studies at subway stations with different control systems.