Dariusz Zieliński

Dr. Dariusz Zieliński

Department of Electrical Drives and Machines, Lublin University of Technology, 20-618 Lublin, Poland
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2020 in IEEE Access
Verified
Journal Article
Open access
MLMateusz Litwin
Mateusz Litwin
DZDariusz Zieliński
Dariusz Zieliński
KGK. Gopakumar
K. Gopakumar
This paper presents a new strategy of active synchronization of an island micro-grid and the utility grid (UG) without measurements at the point of common coupling (PCC). This strategy is based on the assistance of Ethernet communication, GPS pulse-per-second device synchronization, and droop control parameter shift. A strategy with Ethernet-assisted synchronization is used instead of synchronization with dedicated low-bandwidth communication. This strategy is based on exchanging data between two proposed devices: synchronization data sender (SDS) and synchronization data controller (SDC). The SDS calculates the UG voltage parameters and sends these data to the SDC device. The SDC is responsible for receiving synchronization data and calculating droop control parameter shift. The use of GPS-based device synchronization adds very stable and accurate measurements of synchronization parameters that correspond to the stable synchronization signal. As this strategy uses droop control method parameter change, all distributed generators share loads adequately. This strategy introduces the possibility to remove the need for measurement of voltage directly on the switch location. The proposed devices could be connected even a long distance from the PCC. The strategy also introduces the possibility of working in synchronism with the main grid despite the island mode of the micro-grid. This introduces the possibility to connect the micro-grid at the same moment as fault clear or maintenance end.

26 October 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SPSouradeep Pal
Souradeep Pal
KGK. Gopakumar
K. Gopakumar
ULUmanand Loganathan
Umanand Loganathan
Haitham Abu-RubHaitham Abu-Rub
Haitham Abu-Rub
DZDariusz Zieliński
Dariusz Zieliński
This work presents a hybrid seven-level dual inverter scheme with increased linear modulation range. The hybrid inverter structure is formed by supplying the load from primary side by using a cascaded structure of a two-level inverter and H-bridge (HB) and secondary side of the load is supplied by a floating-capacitor-fed two-level inverter. The combination of primary two-level space vector structure (SVS) with secondary two-level SVS and primary three-level SVS of HB form a seven-level SVS that can further be extended to an eight-level hexagonal SVS. This structure then reduced to a 12-sided eight-level SVS to avoid exceeding motor phase voltage rating. Subsequently by using this eight-level SVS in an unique pulsewidth modulation mode, the proposed topology can increase the modulation range linearly from $0.577V_{\text{dc}}$ to $0.637V_{\text{dc}}$ peak phase fundamental voltage for any load power factor (pf), where dc-link voltage is $V_{\text{dc}}$ . An 11 $\%$ increase in modulation range ( $0.637V_{\text{dc}}/0.577V_{\text{dc}}$ ) is possible devoid of lower order harmonics (predominantly $5{\text{th}}$ , $7{\text{th}}$ , $11{\text{th}}$ , $13{\text{th}}$ , etc.) in phase voltage for unity pf load in comparison to the conventional six-step operation of two-level and multilevel hexagonal SVS. To balance HB capacitors voltages in this work, a concept of indirect space vector redundancy is used. The efficacy of the proposed inverter scheme is verified through various experimental results at different steady-state and transient conditions.

11 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
DZDariusz Zieliński
Dariusz Zieliński
BSBartłomiej Stefańczak
Bartłomiej Stefańczak
KJKonrad Jędrys
Konrad Jędrys
The paper presents the reactive power compensation method that allows for reducing the active power flow even in the presence of angular asymmetry between voltage vectors of the utility grid. Reactive power compensation ensures the reduction of power transmission losses and therefore brings significant economic benefits to electricity consumers. The concept of the alternating current/direct current (AC/DC) converter for prosumer applications operating as a local reactive power compensator has been proposed. The system is driven by a multi-resonant algorithm, allowing for independent control of the reactive power in each phase. The proposed method was validated experimentally by using a prototype of the converter, programmable AC source, and grid impedance model. The method made it possible to cover the reactive power demand without unnecessary active power generation and thus to improve the efficiency of the analyzed prototype. This solution can be implemented particularly in radial grids and non-urban areas.

26 September 2022 in IEEE Open Journal of the Industrial Electronics Society
Verified
Journal Article
Open access
TDTutan Debnath
Tutan Debnath
KGK. Gopakumar
K. Gopakumar
LUL. Umanand
L. Umanand
DZDariusz Zieliński
Dariusz Zieliński
Kaushik RajashekaraKaushik Rajashekara
Kaushik Rajashekara
This paper proposes a multilevel inverter topology with a single DC-link and series-connected capacitors as stacked voltage sources for multilevel voltage generation. The voltage deviation of a DC-link capacitor will occur whenever a phase terminal connects to the balanced neutral points (NPs: terminal joints of DC-link capacitors). On the contrary, if the voltage of a DC-link capacitor deviates from the nominal voltage, the same phase currents can be utilised to balance these neutral points. This new technique is being proposed for the first time in literature. Any voltage disturbance of the DC-link capacitors is balanced using the motor phase currents, irrespective of load power factor and modulation indices. For the balanced neutral points, whenever a phase connects to a neutral point, the other phase terminal tapping positions are varied on the DC-link to establish $i_{A}+i_{B}+i_{C}=0$ for that neutral point. The pole voltage level variation at motor phase terminals is undisturbed by adding extra cascaded H-bridges (CHBs) at each phase leg. The voltages of CHB capacitors are controlled conventionally by inverter pole voltage redundancies. The detailed experimental results for open-loop V/ f and closed-loop field-oriented control on an induction motor are presented using a nine-level laboratory prototype.

8 March 2022 in IEEE Access
Verified
Journal Article
Open access
MLMateusz Litwin
Mateusz Litwin
DZDariusz Zieliński
Dariusz Zieliński
SSSebastian Stynski
Sebastian Stynski
The article presents the method of remote micro-grid synchronization with the utility grid in the presence of voltage disturbances. The proposed algorithm and control devices synchronize different power systems on the basis of the instantaneous voltage phase angle in spite of voltage quality problems and without need of access to point of common coupling. In the presence of grid voltage disturbances, instantaneous grid voltage phase angle is estimated and transmitted remotely with a certain accuracy, which is varies in presence of disturbances of grid voltages or depends on the synchronization algorithm and data transmission rate. The paper focuses on the influence of voltage disturbances on the proposed remote synchronization strategy and the shape of the output current of the synchronized power converter on the micro-grid. The four types of grid voltage disturbances are presented: harmonics, one-phase sag, two-phase sag, and phase voltage jump. The final conclusions present the possibility of using the proposed remote synchronizations algorithm in micro-grid power converter applications in the presence of typical utility grid voltage disturbances.

5 May 2015 in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
Verified
Journal Article
Closed access
DZDariusz Zieliński
Dariusz Zieliński
PLPiotr Lipnicki
Piotr Lipnicki
Wojciech JarzynaWojciech Jarzyna
Wojciech Jarzyna