Hayoung Jung

Dr. Hayoung Jung

Transportation Research Institute (UMTRI), University of Michigan–Ann Arbor, Ann Arbor, Michigan, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2018 in Ergonomics
Verified
Journal Article
Closed access
WLWonsup Lee
Wonsup Lee
XYXiaopeng Yang
Xiaopeng Yang
HJHayoung Jung
Hayoung Jung
IBIlgeun Bok
Ilgeun Bok
CKChulwoo Kim
Chulwoo Kim
Heecheon YouHeecheon You
Heecheon You
The present study measured 25 dimensions of the ear including the concha and ear canal for ergonomic design of ear products and compared with existing ear measurement studies. Scanning and casting methods were employed to produce 3D ear images for 230 Koreans and 96 Caucasians and measurements of the ear dimensions were obtained by identifying 21 landmarks on individual ear scan image. The Korean ear measurements were found significantly larger (mean difference d¯ = 0.4–3.7 mm) and more varied (ratio of SDs =1.01–1.55) than those of Caucasians in most of ear dimensions. The average ear length and ear breadth of male were significantly longer ( d¯ = 1.3–7.0 mm) and wider ( d¯ = 0.8–3.0 mm) than those of female. Use of gender- and ethnicity-composite ear data is recommended in product design due to the much larger intra-population variations (7.5–22.2 mm) than the corresponding inter-population variations. Practitioner Summary: The 3D ear measurements of Koreans and Caucasians were collected and compared with those of different ethnic populations. The distinct ear features of the populations identified in this study are applicable to ergonomic design of ear products with better fit and comfort. Abbreviations: CCW: cavum concha width; CV: coefficient of variation; EB: ear breadth; EL: ear length; SD: standard deviation; SE: sampling error; 3D: 3 dimensional

8 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SLSeunghoon Lee
Seunghoon Lee
MKMinjae Kim
Minjae Kim
HJHayoung Jung
Hayoung Jung
DKDohoon Kwon
Dohoon Kwon
SCSunwoo Choi
Sunwoo Choi
Heecheon YouHeecheon You
Heecheon You
Passive task-related (TR) fatigue caused by monotonous driving can negatively affect driving safety by impairing driver alertness and performance. This study aims to evaluate the effectiveness of a motion seat system on the driver’s passive TR fatigue in terms of driving performance, physiological response, and subjective fatigue by using automotive and physiological sensors those applicable to on-road driving environment. Twenty drivers (5 females and 15 males; age = 38.5 ± 12.2) with more than two years of driving experience participated in an on-road experiment with two driving conditions: driving in the static seat condition during the first half of the driving session and then in the static (static–static, SS) or motion seat (static–motion, SM) condition during the second half. The SM condition showed significantly lower passive TR fatigue by 4.4~56.5% compared to the SS condition in terms of the standard deviation of velocity, percentage of eyelid closure rate (PERCLOS), and the ratio of low- to high-frequency power (LF/HF) of electrocardiography signals. The drivers rated significantly lower subjective state changes of overall fatigue, mental fatigue, passive TR fatigue, drowsiness, and decreased concentration in the SM condition than those in the SS condition. The findings of the study support the use of a motion seat system can be an effective countermeasure to reduce passive TR fatigue.

20 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
BPByoung-Keon D. Park
Byoung-Keon D. Park
HJHayoung Jung
Hayoung Jung
SESheila M. Ebert
Sheila M. Ebert
BCBrian D. Corner
Brian D. Corner
Matthew ReedMatthew Reed
Matthew Reed
Measuring human body dimensions is critical for many engineering and product design domains. Nonetheless, acquiring body dimension data for populations using typical anthropometric methods poses challenges due to the time-consuming nature of manual methods. The measurement process for three-dimensional (3D) whole-body scanning can be much faster, but 3D scanning typically requires subjects to change into tight-fitting clothing, which increases time and cost and introduces privacy concerns. To address these and other issues in current anthropometry techniques, a measurement system was developed based on portable, low-cost depth cameras. Point-cloud data from the sensors are fit using a model-based method, Inscribed Fitting, which finds the most likely body shape in the statistical body shape space and providing accurate estimates of body characteristics. To evaluate the system, 144 young adults were measured manually and with two levels of military ensembles using the system. The results showed that the prediction accuracy for the clothed scans remained at a similar level to the accuracy for the minimally clad scans. This approach will enable rapid measurement of clothed populations with reduced time compared to manual and typical scan-based methods.

21 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XYXiaopeng Yang
Xiaopeng Yang
ZLZhichan Lim
Zhichan Lim
HJHayoung Jung
Hayoung Jung
YHYounggi Hong
Younggi Hong
MZMengfei Zhang
Mengfei Zhang
Heecheon YouHeecheon You
Heecheon You
The present study proposed a method to estimate the finite finger joint centers of rotation (CoRs) with high accuracy using 3D hand skeleton motions reconstructed from CT scans. Ten hand postures starting from a fully extended posture and ending at a fist posture with about 10° difference in flexion between the adjacent postures were captured by a CT scanner for 15 male participants, and their 3D hand skeletons were reconstructed using the CT scans. Each bone segment from the full extension posture was registered to the corresponding bone segments of the remaining hand postures. The proximal bone segments of a joint from two postures were aligned to estimate the finite CoR of the joint between the two postures. Centerlines of the distal bone segments of the joint were then identified using the principal component analysis method, and the finite CoR of the joint was determined as the intersection point of the identified centerlines. The proposed method reduced the variation of estimated finite joint CoRs by 16.0% to 67.0% among the finger joints compared to the existing methods. The variation of estimated finite joint CoRs decreased as the rotation angle of the joint increased. The proposed method can be used for the simulation of finger movement with high accuracy.

11 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HJHayoung Jung
Hayoung Jung
XCXin Cui
Xin Cui
HKHa Kim
Ha Kim
MLMingkang Li
Mingkang Li
CLChanghao Liu
Changhao Liu
Heecheon YouHeecheon You
Heecheon You
An optical brain-machine interface (O-BMI) system using calcium imaging has various advantages such as high resolution, a comprehensive view of large neural populations, abilities such as long-term stable recording, and applicability to freely behaving animals in neuroscience research. The present study developed an ergonomic user interface (UI) design, based on a use scenario for an O-BMI system that can be used for the acquisition and processing of calcium imaging in freely behaving rodents. The UI design was developed in three steps: (1) identification of design and function requirements of users, (2) establishment of a use scenario, and (3) development of a UI prototype. The UI design requirements were identified by a literature review, a benchmark of existing systems, and a focus group interview with five neuroscience researchers. Then, the use scenario was developed for tasks of data acquisition, feature extraction, and neural decoding for offline and online processing by considering the sequences of operations and needs of users. Lastly, a digital prototype incorporating an information architecture, graphic user interfaces, and simulated functions was fabricated. A usability test was conducted with five neuroscientists (work experience = 3.4 ± 1.1 years) and five ergonomic experts (work experience = 3.6 ± 2.7 years) to compare the digital prototypes with four existing systems (Miniscope, nVista, Mosaic, and Suite2p). The usability testing results showed that the ergonomic UI design was significantly preferred to the UI designs of the existing systems by reducing the task completion time by 10.1% to 70.2% on average, the scan path length by 14.4% to 88.7%, and perceived workload by 12.2% to 37.9%, increasing satisfaction by 11.3% to 74.3% in data acquisition and signal-extraction tasks. The present study demonstrates the significance of the user-centered design approach in the development of a system for neuroscience research. Further research is needed to validate the usability test results of the UI prototype as a corresponding real system is implemented.

27 January 2023 in Children
Verified
Journal Article
Open access
PDF file
RYRa Yu Yun
Ra Yu Yun
HJHayoung Jung
Hayoung Jung
XCXin Cui
Xin Cui
SHSungchul Huh
Sungchul Huh
WLWonsup Lee
Wonsup Lee
SKSoo-Yeon Kim
Soo-Yeon Kim
The head tilt of patients with torticollis is usually evaluated subjectively in clinical practice and measuring it in young children is very limited due to poor cooperation. No study has yet evaluated the head tilt using a three-dimensional (3D) scan and compared it with other measurement methods. Therefore, this study aimed to objectively demonstrate head tilt through clinical measurements and a 3D scan in children with torticollis. A total of 52 children (30 males, 22 females; age 4.6 ± 3.2 years) diagnosed with torticollis and 52 adults (26 men, 26 women; age 34.42 ± 10.4 years) without torticollis participated in this study. The clinical measurements were performed using a goniometer and still photography methods. Additionally, the head tilt was analyzed using a 3D scanner (3dMD scan, 3dMD Inc., Atlanta, GA, USA). There was a high correlation between the other methods and 3D angles, and the cut-off value of the 3D angles for the diagnosis of torticollis was also presented. The area under the curve of the 3D angle was 0.872, which was confirmed by a moderately accurate test and showed a strong correlation compared with other conventional tests. Therefore, we suggest that measuring the degree of torticollis three-dimensionally is significant.