Riccardo Belardi

Mr. Riccardo Belardi

University of Florence Italy

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Igor AizenbergIgor Aizenberg
Igor Aizenberg
Riccardo BelardiRiccardo Belardi
Riccardo Belardi
Marco BindiMarco Bindi
Marco Bindi
Francesco GrassoFrancesco Grasso
Francesco Grasso
Stefano ManettiStefano Manetti
Stefano Manetti
MPMaria Cristina Piccirilli
Maria Cristina Piccirilli
In this paper, we present a new method designed to recognize single parametric faults in analog circuits. The technique follows a rigorous approach constituted by three sequential steps: calculating the testability and extracting the ambiguity groups of the circuit under test (CUT); localizing the failure and putting it in the correct fault class (FC) via multi-frequency measurements or simulations; and (optional) estimating the value of the faulty component. The fabrication tolerances of the healthy components are taken into account in every step of the procedure. The work combines machine learning techniques, used for classification and approximation, with testability analysis procedures for analog circuits.

25 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
Igor AizenbergIgor Aizenberg
Igor Aizenberg
Riccardo BelardiRiccardo Belardi
Riccardo Belardi
Marco BindiMarco Bindi
Marco Bindi
Francesco GrassoFrancesco Grasso
Francesco Grasso
Stefano ManettiStefano Manetti
Stefano Manetti
MPMaria Cristina Piccirilli
Maria Cristina Piccirilli
A smart monitoring system capable of detecting and classifying the health conditions of MV (Medium Voltage) underground cables is presented in this work. Using the analysis technique proposed here, it is possible to prevent the occurrence of catastrophic failures in medium voltage underground lines, for which it is generally difficult to realize maintenance operations and carry out punctual inspections. This prognostic method is based on Frequency Response Analysis (FRA) and can be used online during normal network operation, resulting in a minimally invasive tool. In order to obtain the good results shown in the simulation section, it is necessary to develop a lamped equivalent circuit of the network branch under consideration. The standard π-model is used in this paper to analyse sections of a medium voltage cable and the parameter variations with temperature are used to classify the state of health of the line. In fact, the variation of the electrical parameters produces a corresponding variation in the frequency response. The proposed system is based on the use of a complex neural network with feedforward architecture. It processes the frequency response, allowing the classification of the cable conditions with an accuracy higher than 90%.

1 August 2020 in Advances in Science, Technology and Engineering Systems Journal
Verified
Journal Article
Open access
Marco BindiMarco Bindi
Marco Bindi
IAIgor Aizenberg
Igor Aizenberg
Riccardo BelardiRiccardo Belardi
Riccardo Belardi
FGFrancesco Grasso
Francesco Grasso
ALAntonio Luchetta
Antonio Luchetta
MPMaria Cristina Piccirilli
Maria Cristina Piccirilli