julio TORRES MARTÍN

Dr. julio TORRES MARTÍN

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Cement and Concrete Composites
Verified
Journal Article
Closed access
LMLaura Caneda Martínez
Laura Caneda Martínez
Javier SanchezJavier Sanchez
Javier Sanchez
César MedinaCésar Medina
César Medina
MRM. Isabel Sánchez de Rojas
M. Isabel Sánchez de Rojas
JMjulio TORRES MARTÍN
julio TORRES MARTÍN
MFMoisés Frías
Moisés Frías

10 August 2016 in Materials and Structures
Verified
Journal Article
Closed access
PDF file
Javier SanchezJavier Sanchez
Javier Sanchez
CACarmen Andrade
Carmen Andrade
JMjulio TORRES MARTÍN
julio TORRES MARTÍN
NRNuria Rebolledo Ramos
Nuria Rebolledo Ramos
JFJose Fullea
Jose Fullea

1 September 2017 in Engineering Failure Analysis
Verified
Journal Article
Closed access
Javier SanchezJavier Sanchez
Javier Sanchez
Oscar GalaoOscar Galao
Oscar Galao
JMjulio TORRES MARTÍN
julio TORRES MARTÍN
JFJose Fullea
Jose Fullea
CACarmen Andrade
Carmen Andrade
PCPedro Cano
Pedro Cano

20 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
Servando Chinchón-PayáServando Chinchón-Payá
Servando Chinchón-Payá
JMjulio TORRES MARTÍN
julio TORRES MARTÍN
ATAntonio Silva Toledo
Antonio Silva Toledo
Javier SanchezJavier Sanchez
Javier Sanchez
A correct assessment of the pathologies that can affect a reinforced concrete structure is required in order to define the repair procedure. This work addresses the challenge of quantifying chlorides and sulphates directly on the surface of concrete. The quantification was carried out by means of X-ray fluorescence analysis on the surface of concrete specimens at different points with portable equipment. Concrete prisms were made with different amounts of NaCl and Na2SO4. To avoid the influence of coarse aggregate, a qualitative estimate of the amount of coarse aggregate analyzed has been made, although the results show that there is no significant influence. Monte Carlo simulations were carried out in order to establish the necessary number of random analyses of the mean value to be within an acceptable range of error. In the case of quantifying sulphates, it is necessary to carry out six random analyses on the surface, and eight measurements in the case of quantifying chlorides; in this way, it is ensured that errors are below 10% in 95% of the cases. The results of the study highlight that a portable XRF device can be used in situ to obtain concentrations of chlorides and sulphates of a concrete surface with good accuracy. There is no need to take samples and bring them to a laboratory, allowing lower overall costs in inspection and reparation works.

11 July 2019 in Frontiers in Materials
Verified
Journal Article
Open access
JMJuan A. Morales
Juan A. Morales
JMjulio TORRES MARTÍN
julio TORRES MARTÍN
NRNuria Rebolledo
Nuria Rebolledo
Javier SanchezJavier Sanchez
Javier Sanchez
It is commonly mentioned that corrosion of steel in presstressed concrete can induce brittle failure. It is also understood that in order to estimate the presstressed structures service life is necessary to study the pitting factor that compares the maximum corrosion pit depth with the section loss by homogeneous corrosion. Results are presented on corrosion tests to measure the corrosion depth in tendons in contact with water. In present paper, a statistical analysis has been carried out in order to obtain the pitting factor for different cross sections submerged in water. The results indicate that the pitting factor value varies between 1.20 and 1.85 depending on the confidence interval considered, which can significantly reduce the service life of the presstressed tendons as long as the exposure conditions are those set out in this study.

12 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
EGElena García
Elena García
JMjulio TORRES MARTÍN
julio TORRES MARTÍN
NRNuria Rebolledo Ramos
Nuria Rebolledo Ramos
Raúl ArrabalRaúl Arrabal
Raúl Arrabal
Javier SanchezJavier Sanchez
Javier Sanchez
The number of reinforced concrete structures subject to anoxic conditions such as offshore platforms and geological storage facilities is growing steadily. This study explored the behaviour of embedded steel reinforcement corrosion under anoxic conditions in the presence of different chloride concentrations. Corrosion rate values were obtained by three electrochemical techniques: Linear polarization resistance, electrochemical impedance spectroscopy, and chronopotenciometry. The corrosion rate ceiling observed was 0.98 µA/cm2, irrespective of the chloride content in the concrete. By means of an Evans diagram, it was possible to estimate the value of the cathodic Tafel constant (bc) to be 180 mV dec−1, and the current limit yielded an ilim value of 0.98 µA/cm2. On the other hand, the corrosion potential would lie most likely in the −900 mVAg/AgCl to −1000 mVAg/AgCl range, whilst the bounds for the most probable corrosion rate were 0.61 µA/cm2 to 0.22 µA/cm2. The experiments conducted revealed clear evidence of corrosion-induced pitting that will be assessed in subsequent research.