The paper presents results of numerical simulation and experimental testing of a microwave sensor for non-invasive glucose monitoring. The sensor represents a conical horn with a conical conductor inside expanding toward the horn aperture. Such a sensor has a significantly wider passband in comparison with sensors of other designs. It is essential that the sensor geometry provides formation of an extended near-field zone with high electric field strength near the sensor aperture. A clear relationship between the dielectric permittivity of the phantom biological tissue and the frequency dependence of the parameter S11 of the sensor is observed at frequencies in the range from 1.4 to 1.7 GHz. This circumstance can be used to develop a procedure for measuring the glucose level in blood that correlates with the parameter S11 of the sensor. From the viewpoint of monitoring of the glucose content in blood, the most convenient body sensor location is on the hands or feet, in particular, wrists.
The article presents the design of the near-field probe, which is a combined emitter (a combination of a symmetric dipole and an annular frame). The design of the probe allows forming a prolonged zone of the near-field. This effect can be used for in-depth penetration of the field in media with high absorption, without loss of information. Particular attention in this article is given to a detailed study of the interaction of the field created by this probe on plane-layered biological media. A theoretical analysis of the interaction of the electromagnetic field was carried out in a wide frequency band with a model plane-layer biological medium containing blood vessels of shallow depth using the proposed probe design. Conclusions are drawn about the depth of penetration of a useful signal into different media-analogs of biological tissue. This study is necessary to consider the possibility of using this probe for non-invasive measurements of blood glucose concentration. The studies were carried out using numerical simulation in the CST (Computer Simulation Technology) Microwave Studio environment. All biological tissues were simulated over a wide frequency range from 10 MHz to 10 GHz.
It is shown theoretically and experimentally that in the field of an electromagnetic radiator located in an absorbing medium, there exists a virtual surface that encompasses the near-field zone and is referred to as causal in the present study at which the field undergoes a second order phase transition. This transition is characterized by a rapidly changing phase and conversion of the energy of the quasistatic/reactive field into the energy of the field in the state of radiation. Behind the causal surface, the law of phase change sufficiently quickly acquires a linear character, and the field strength decreases with an increase in the distance following either an inverse-square law or an exponential function depending on the absorption coefficient of the medium, which is manifested through the formation of an intensively absorbing layer. Within the near zone, exponential attenuation is not observed. The size of the near zone depends on the frequency and the refractive index of the medium. Based on the studies performed, a new approach to the problem of sensing of absorbing media is suggested.
The article investigates the near-field probe of a special design to account for changes in glucose concentration. The probe is designed in such a way that it emits radiation in both directions from its plane. In this paper, it was proposed to modernize this design and consider the unidirectional emission of the probe in order to maximize the signal and reduce energy loss. We have done extensive research for both bidirectional and unidirectional probe designs. Numerical simulations and field experiments were carried out to determine different concentrations of glucose (0, 4, 5.3, 7.5 mmol/L). Numerical modeling of a unidirectional probe showed that the interaction of radiation generated by such a probe with a multilayer structure simulating a human hand showed a better result and high sensitivity compared to a bidirectional probe. Further, based on the simulation results, a phantom (physical model) of a human hand was recreated from layers with dielectric properties as close as possible to the properties of materials during simulation. The probe was constructed from a copper tube and matched both the geometric and physical parameters of the model. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz for the unidirectional and bidirectional probes. Further, the results of the experiment were compared with the results of numerical simulation. According to the results of multiple experiments, it was found that the average deviation between the concentrations was 2 dB for a unidirectional probe and 0.4 dB for a bidirectional probe. Thus, the sensitivity of the unidirectional probe was 1.5 dB/(mmol/L) for the bidirectional one 0.3 dB/(mmol/L). Thus, the improved design of the near-field probe can be used to record glucose concentrations.