The paper presents results of numerical simulation and experimental testing of a microwave sensor for non-invasive glucose monitoring. The sensor represents a conical horn with a conical conductor inside expanding toward the horn aperture. Such a sensor has a significantly wider passband in comparison with sensors of other designs. It is essential that the sensor geometry provides formation of an extended near-field zone with high electric field strength near the sensor aperture. A clear relationship between the dielectric permittivity of the phantom biological tissue and the frequency dependence of the parameter S11 of the sensor is observed at frequencies in the range from 1.4 to 1.7 GHz. This circumstance can be used to develop a procedure for measuring the glucose level in blood that correlates with the parameter S11 of the sensor. From the viewpoint of monitoring of the glucose content in blood, the most convenient body sensor location is on the hands or feet, in particular, wrists.
In a conventional GPS receiver, the carrier tracking system is the key stage that keeps the receiver locked to the radio navigation parameters (RNPs) of the received signal. The most commonly used approaches to the tracking system are phase lock loop (PLL), frequency lock loop (FLL), and FLL-assisted PLL. The main limitation of the above approaches is that their performance deteriorates when working with weak signals and in harsh environments. In recent years, Kalman filter (KF)-based tracking loop architectures have gained increased attention due to their robust and better performance compared with conventional architectures. In this paper, a novel Gauss–Hermite Kalman filtering-based carrier tracking algorithm is proposed for static and moving receivers with weak GPS signals. The performance of the proposed algorithm is compared with two other approaches: extended Kalman filter (EKF) and unscented Kalman filter (UKF). Simulations were conducted using a software-defined GPS simulator and software device radio (SDR) modules. A comparative analysis of the tracking methods demonstrated that the proposed tracking method shows a better performance and improves the tracking sensitivity and capability under weak signal conditions as compared with EKF- and UKF-based tracking methods. In addition, the results show that the proposed approach improves the Doppler frequency measurement accuracy under dynamic operation conditions.
The article investigates the near-field probe of a special design to account for changes in glucose concentration. The probe is designed in such a way that it emits radiation in both directions from its plane. In this paper, it was proposed to modernize this design and consider the unidirectional emission of the probe in order to maximize the signal and reduce energy loss. We have done extensive research for both bidirectional and unidirectional probe designs. Numerical simulations and field experiments were carried out to determine different concentrations of glucose (0, 4, 5.3, 7.5 mmol/L). Numerical modeling of a unidirectional probe showed that the interaction of radiation generated by such a probe with a multilayer structure simulating a human hand showed a better result and high sensitivity compared to a bidirectional probe. Further, based on the simulation results, a phantom (physical model) of a human hand was recreated from layers with dielectric properties as close as possible to the properties of materials during simulation. The probe was constructed from a copper tube and matched both the geometric and physical parameters of the model. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz for the unidirectional and bidirectional probes. Further, the results of the experiment were compared with the results of numerical simulation. According to the results of multiple experiments, it was found that the average deviation between the concentrations was 2 dB for a unidirectional probe and 0.4 dB for a bidirectional probe. Thus, the sensitivity of the unidirectional probe was 1.5 dB/(mmol/L) for the bidirectional one 0.3 dB/(mmol/L). Thus, the improved design of the near-field probe can be used to record glucose concentrations.
30 August 2017 in Journal of Physics: Conference Series
The work deals with study of peat deposits of oligotrophic bog and spatial distribution of snow cover by geolocation. Data from ground penetrating radar were compared with the data of conventional measurements of a peat depth and snow cover. A fairly good agreement between the thickness of the peat deposits, snow depth by using ground penetrating radar and the data of conventional measurements has been obtained.