In the past, the main research and use of scintillators in extreme environments were mainly limited to high energy physics and the well-logging industry, but their applications are now expanding to reactor monitoring systems, marine and space exploration, nuclear fusion, radiation therapy, etc. In this article, we review and summarize single-crystal inorganic scintillator candidates that can be applied to radiation detection in extreme environments. Crucial scintillation properties to consider for use in extreme environments are temperature dependence and radiation resistance, along with scintillators’ susceptibility to moisture and mechanical shock. Therefore, we report on performance change, with a focus on radiation resistance and temperature dependence, and the availability of inorganic scintillator for extreme environments—high radiation, temperature, humidity and vibration—according to their applications. In addition, theoretical explanations for temperature dependence and radiation resistance are also provided.
30 June 2019 in Journal of Radiation Protection and Research
Background: As neutron fields are always accompanied by gamma rays, it is essential to distinguish neutrons from gamma rays in the detection of neutrons. Neutrons and gamma rays can be separated by pulse shape discrimination (PSD) methods. Recently, we performed characterization of a stilbene scintillator detector and an EJ-301 liquid scintillator detector with a highspeed digitizer DT5730 and investigated optimized PSD variables for both detectors. This study is for providing a basis for developing fast neutron/gamma-ray dual-particle imager. Materials and Methods: We conducted PSD experiments using stilbene scintillator and EJ-301 liquid scintillator and evaluated neutron and gamma ray discriminability of each PSD method with a 137 Cs gamma source and a 252 Cf neutron source. We implemented digital signal processing techniques to apply two PSD methods-the charge comparison (CC) method and the constant time discrimination (CTD) method-to distinguish neutrons from gamma rays. We tried to find optimized PSD variables giving the best discriminability in a given experimental condition. Results and Discussion: For the stilbene scintillator detector, the charge comparison method and the constant time discrimination method both delivered the PSD FOM values of 1.7. For the EJ-301 liquid scintillator detector, both PSD methods delivered the PSD FOM values of 1.79. With the same PSD variables, PSD performance was excellent in 300 ± 100 keVee, 500 ± 100 keVee, and 700 ± 100 keVee energy regions. This result shows that we can achieve an effective discrimination of neutrons from gamma rays using these scintillator detector systems. Conclusion: We applied both PSD methods to a stilbene and a liquid scintillator and optimized the PSD performance represented by FOM values. We observed a good separation performance of both scintillators combined with a high-speed digitizer and digital PSD. These results will provide reference values for the dual-particle imager we are developing, which can image both fast neutrons and gamma rays simultaneously.
We propose an integrated front-end data acquisition circuit for a hybrid ultrasound (US)-gamma probe. The proposed circuit consists of three main parts: (1) a preamplifier for the gamma probe, (2) a preprocessing analog circuit for the US, and (3) a digitally controlled analog switch. By exploiting the long idle time of the US system, an analog switch can be used to acquire data of both systems using a single output channel simultaneously. On the nuclear medicine (NM) gamma probe side, energy resolutions of 18.4% and 17.5% were acquired with the standalone system and with the proposed switching circuit, respectively, when irradiated with a Co-57 radiation source. Similarly, signal-to-noise ratios of 14.89 and 13.12 dB were achieved when US echo signals were acquired with the standalone system and with the proposed switching circuit, respectively. Lastly, a combined US-gamma probe was used to scan a glass target and a sealed radiation source placed in a water tank. The results confirmed that, by using a hybrid US-gamma probe system, it is possible to distinguish between the two objects and acquire structural information (ultrasound) alongside molecular information (gamma radiation source).
An as-fabricated cerium-doped ceramic scintillator Gd3Al2Ga3O12 (Ce:GAGG) was thermally annealed at different temperatures. The light output and energy res