Yuseung Park

Mr. Yuseung Park

Department of Bioengineering, Korea University, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MUMuhammad Nasir Ullah
Muhammad Nasir Ullah
Yuseung ParkYuseung Park
Yuseung Park
GKGyeong Beom Kim
Gyeong Beom Kim
CKChanho Kim
Chanho Kim
CPChansun Park
Chansun Park
JYJung Yeol Yeom
Jung Yeol Yeom
We propose an integrated front-end data acquisition circuit for a hybrid ultrasound (US)-gamma probe. The proposed circuit consists of three main parts: (1) a preamplifier for the gamma probe, (2) a preprocessing analog circuit for the US, and (3) a digitally controlled analog switch. By exploiting the long idle time of the US system, an analog switch can be used to acquire data of both systems using a single output channel simultaneously. On the nuclear medicine (NM) gamma probe side, energy resolutions of 18.4% and 17.5% were acquired with the standalone system and with the proposed switching circuit, respectively, when irradiated with a Co-57 radiation source. Similarly, signal-to-noise ratios of 14.89 and 13.12 dB were achieved when US echo signals were acquired with the standalone system and with the proposed switching circuit, respectively. Lastly, a combined US-gamma probe was used to scan a glass target and a sealed radiation source placed in a water tank. The results confirmed that, by using a hybrid US-gamma probe system, it is possible to distinguish between the two objects and acquire structural information (ultrasound) alongside molecular information (gamma radiation source).

23 September 2025 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MUMuhammad Nasir Ullah
Muhammad Nasir Ullah
MWMuhammad Waqar
Muhammad Waqar
Yuseung ParkYuseung Park
Yuseung Park
GKGyeong Beom Kim
Gyeong Beom Kim
KCKyungseok Choi
Kyungseok Choi
JYJung-Yeol Yeom
Jung-Yeol Yeom
This paper presents the first fully integrated, highly compact single-element integrated Gamma-Ultrasound (γ-US) probe for simultaneous molecular and anatomical imaging. The probe integrates a PZT-5A US transducer with a Ce:GAGG scintillator and silicon photomultiplier (SiPM), enabling dual-modality detection along the same line-of-sight (LOS). The tungsten-epoxy composite serves dual roles as both the US backing layer and γ collimator, making it innovative and significantly reduces size and complexity. Furthermore, a single-channel frequency-based multiplexed circuit enables real-time dual-modality data acquisition. The γ part of the probe achieves 17.3% energy resolution (FWHM at 122 keV), 80.0 cps/MBq sensitivity, and 2.69 mm spatial resolution at 1 cm distance in air. The US component provides a 5.95 dB SNR, 1.32 mm axial resolution, and 4.90 mm lateral resolution at 5 cm depth in water. Finally, a fused B-mode image of a breast phantom validates the probe’s imaging capability. This integrated probe design offers a compact, cost-effective solution for handheld medical diagnostics and non-destructive testing, with minimal performance trade-offs compared to standalone systems.