Mehdi Mohammadi

Dr. Mehdi Mohammadi

Department of Biological Sciences, University of Calgary, Calgary, AB T2N 1N4, Canada
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2021 in Vaccines
Verified
Journal Article
Open access
PDF file
Ali PormohammadAli Pormohammad
Ali Pormohammad
MZMohammad Zarei
Mohammad Zarei
SGsaied ghorbani
saied ghorbani
Mehdi MohammadiMehdi Mohammadi
Mehdi Mohammadi
MRMohammad Hossein Razizadeh
Mohammad Hossein Razizadeh
Raymond TurnerRaymond Turner
Raymond Turner
The current study systematically reviewed, summarized and meta-analyzed the clinical features of the vaccines in clinical trials to provide a better estimate of their efficacy, side effects and immunogenicity. All relevant publications were systematically searched and collected from major databases up to 12 March 2021. A total of 25 RCTs (123 datasets), 58,889 cases that received the COVID-19 vaccine and 46,638 controls who received placebo were included in the meta-analysis. In total, mRNA-based and adenovirus-vectored COVID-19 vaccines had 94.6% (95% CI 0.936–0.954) and 80.2% (95% CI 0.56–0.93) efficacy in phase II/III RCTs, respectively. Efficacy of the adenovirus-vectored vaccine after the first (97.6%; 95% CI 0.939–0.997) and second (98.2%; 95% CI 0.980–0.984) doses was the highest against receptor-binding domain (RBD) antigen after 3 weeks of injections. The mRNA-based vaccines had the highest level of side effects reported except for diarrhea and arthralgia. Aluminum-adjuvanted vaccines had the lowest systemic and local side effects between vaccines’ adjuvant or without adjuvant, except for injection site redness. The adenovirus-vectored and mRNA-based vaccines for COVID-19 showed the highest efficacy after first and second doses, respectively. The mRNA-based vaccines had higher side effects. Remarkably few experienced extreme adverse effects and all stimulated robust immune responses.

2 January 2021 in Reviews in Medical Virology
Verified
Journal Article
Closed access
PDF file
MJMaryamsadat Jafari
Maryamsadat Jafari
APAli Pormohammad
Ali Pormohammad
SNSaeideh Aghayari Sheikh Neshin
Saeideh Aghayari Sheikh Neshin
SGsaied ghorbani
saied ghorbani
DBDeepanwita Bose
Deepanwita Bose
MZMohammad Zarei
Mohammad Zarei

25 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RNRakesh Narang
Rakesh Narang
SMSevda Mohammadi
Sevda Mohammadi
Mehdi MohammadiMehdi Mohammadi
Mehdi Mohammadi
HSHamid Sadabadi
Hamid Sadabadi
HHHossein Hejazi
Hossein Hejazi
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad
Infection diagnosis and antibiotic susceptibility testing (AST) are time-consuming and often laborious clinical practices. This paper presents a microwave-microfluidic biosensor for rapid, contactless and non-invasive device for testing the concentration and growth of Escherichia Coli (E. Coli) in medium solutions of different pH to increase the efficacy of clinical microbiology practices. The thin layer interface between the microfluidic channel and the microwave resonator significantly enhanced the detection sensitivity. The microfluidic chip, fabricated using standard soft lithography, was injected with bacterial samples and incorporated with a microwave microstrip ring resonator sensor with an operation frequency of 2.5 GHz and initial quality factor of 83 for detecting the concentration and growth of bacteria. The resonator had a coupling gap area on of 1.5 × 1.5 mm2 as of its sensitive region. The presence of different concentrations of bacteria in different pH solutions were detected via screening the changes in resonant amplitude and frequency responses of the microwave system. The sensor device demonstrated near immediate response to changes in the concentration of bacteria and maximum sensitivity of 3.4 MHz compared to a logarithm value of bacteria concentration. The minimum prepared optical transparency of bacteria was tested at an OD600 value of 0.003. The sensor’s resonant frequency and amplitude parameters were utilized to monitor bacteria growth during a 500-minute time frame, which demonstrated a stable response with respect to detecting the bacterial proliferation. A highly linear response was demonstrated for detecting bacteria concentration at various pH values. The growth of bacteria analyzed over the resonator showed an exponential growth curve with respect to time and concurred with the lag-log-stationary-death model of cell growth. This biosensor is one step forward to automate the complex AST workflow of clinical microbiology laboratories for rapid and automated detection of bacteria as well as screening the bacteria proliferation in response to antibiotics.

1 January 2018 in Drug Delivery
Verified
Journal Article
Open access
MMMohammad K. D. Manshadi
Mohammad K. D. Manshadi
MSMahsa Saadat
Mahsa Saadat
Mehdi MohammadiMehdi Mohammadi
Mehdi Mohammadi
MSMilad Shamsi
Milad Shamsi
Morteza DejamMorteza Dejam
Morteza Dejam
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad
Magnetic drug targeting (MDT) and magnetic-based drug/cargo delivery are emerging treatment methods which attracting the attention of many researchers for curing different cancers and artery diseases such as atherosclerosis. Herein, computational studies are accomplished by utilizing magnetic approaches for cancer and artery atherosclerosis drug delivery, including nanomagnetic drug delivery and magnetic-based drug/cargo delivery. For the first time, the four-layer structural model of the artery tissue and its porosity parameters are modeled in this study which enables the interaction of particles with the tissue walls in blood flow. The effects of parameters, including magnetic field strength (MFS), magnet size, particle size, the initial position of particles, and the relative magnetic permeability of particles, on the efficacy of MDT through the artery walls are characterized. The magnetic particle penetration into artery layers and fibrous cap (the covering layer over the inflamed part of the artery) is further simulated. The MDT in healthy and diseased arteries demonstrates that some of the particles stuck in these tissues due to the collision of particles or blood flow deviation in the vicinity of the inflamed part of the artery. Therefore the geometry of artery and porosity of its layers should be considered to show the real interaction of particles with the artery walls. Also, the results show that increasing the particles/drug/cargo size and MFS leads to more particles/drug/cargo retention within the tissue. The present work provides insights into the decisive factors in arterial MDT with an obvious impact on locoregional cancer treatment, tissue engineering, and regenerative medicine.

1 July 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Mehdi MohammadiMehdi Mohammadi
Mehdi Mohammadi
HZHossein Zargartalebi
Hossein Zargartalebi
RSRazieh Salahandish
Razieh Salahandish
RARaied Aburashed
Raied Aburashed
KYKar Wey Yong
Kar Wey Yong
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad

1 December 2020 in Journal of Controlled Release
Verified
Journal Article
Closed access
MSMahsa Saadat
Mahsa Saadat
MMMohammad K.D. Manshadi
Mohammad K.D. Manshadi
Mehdi MohammadiMehdi Mohammadi
Mehdi Mohammadi
MZMohammad Javad Zare
Mohammad Javad Zare
MZMohammad Zarei
Mohammad Zarei
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad