Amir Sanati-Nezhad

Prof. Amir Sanati-Nezhad

Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Dr NW, Calgary, AB T2N 1N4, Canada

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Acta Biomaterialia
Verified
Journal Article
Closed access
AVArmin Vedadghavami
Armin Vedadghavami
FMFarnaz Minooei
Farnaz Minooei
MMMohammad Hossein Mohammadi
Mohammad Hossein Mohammadi
SKSultan Khetani
Sultan Khetani
AKAhmad Rezaei Kolahchi
Ahmad Rezaei Kolahchi
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad

25 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RNRakesh Narang
Rakesh Narang
SMSevda Mohammadi
Sevda Mohammadi
Mehdi MohammadiMehdi Mohammadi
Mehdi Mohammadi
HSHamid Sadabadi
Hamid Sadabadi
HHHossein Hejazi
Hossein Hejazi
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad
Infection diagnosis and antibiotic susceptibility testing (AST) are time-consuming and often laborious clinical practices. This paper presents a microwave-microfluidic biosensor for rapid, contactless and non-invasive device for testing the concentration and growth of Escherichia Coli (E. Coli) in medium solutions of different pH to increase the efficacy of clinical microbiology practices. The thin layer interface between the microfluidic channel and the microwave resonator significantly enhanced the detection sensitivity. The microfluidic chip, fabricated using standard soft lithography, was injected with bacterial samples and incorporated with a microwave microstrip ring resonator sensor with an operation frequency of 2.5 GHz and initial quality factor of 83 for detecting the concentration and growth of bacteria. The resonator had a coupling gap area on of 1.5 × 1.5 mm2 as of its sensitive region. The presence of different concentrations of bacteria in different pH solutions were detected via screening the changes in resonant amplitude and frequency responses of the microwave system. The sensor device demonstrated near immediate response to changes in the concentration of bacteria and maximum sensitivity of 3.4 MHz compared to a logarithm value of bacteria concentration. The minimum prepared optical transparency of bacteria was tested at an OD600 value of 0.003. The sensor’s resonant frequency and amplitude parameters were utilized to monitor bacteria growth during a 500-minute time frame, which demonstrated a stable response with respect to detecting the bacterial proliferation. A highly linear response was demonstrated for detecting bacteria concentration at various pH values. The growth of bacteria analyzed over the resonator showed an exponential growth curve with respect to time and concurred with the lag-log-stationary-death model of cell growth. This biosensor is one step forward to automate the complex AST workflow of clinical microbiology laboratories for rapid and automated detection of bacteria as well as screening the bacteria proliferation in response to antibiotics.

9 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MZMohammad Hossein Zarifi
Mohammad Hossein Zarifi
HSHamid Sadabadi
Hamid Sadabadi
SHS. Hossein Hejazi
S. Hossein Hejazi
MDMojgan Daneshmand
Mojgan Daneshmand
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad
A novel flow sensor is presented to measure the flow rate within microchannels in a real-time, noncontact and nonintrusive manner. The microfluidic device is made of a fluidic microchannel sealed with a thin polymer layer interfacing the fluidics and microwave electronics. Deformation of the thin circular membrane alters the permittivity and conductivity over the sensitive zone of the microwave resonator device and enables high-resolution detection of flow rate in microfluidic channels using non-contact microwave as a standalone system. The flow sensor has the linear response in the range of 0–150 µl/min for the optimal sensor performance. The highest sensitivity is detected to be 0.5 µl/min for the membrane with the diameter of 3 mm and the thickness of 100 µm. The sensor is reproducible with the error of 0.1% for the flow rate of 10 µl/min. Furthermore, the sensor functioned very stable for 20 hrs performance within the cell culture incubator in 37 °C and 5% CO2 environment for detecting the flow rate of the culture medium. This sensor does not need any contact with the liquid and is highly compatible with several applications in energy and biomedical engineering, and particularly for microfluidic-based lab-on-chips, micro-bioreactors and organ-on-chips platforms.

1 November 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Razieh SalahandishRazieh Salahandish
Razieh Salahandish
AGAli Ghaffarinejad
Ali Ghaffarinejad
EOEskandar Omidinia
Eskandar Omidinia
HZHossein Zargartalebi
Hossein Zargartalebi
KMKeivan Majidzadeh-A
Keivan Majidzadeh-A
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad

7 November 2016 in RSC Advances
Verified
Journal Article
Closed access
PDF file
HMH. Pezeshgi Modarres
H. Pezeshgi Modarres
MMM. R. Mofrad
M. R. Mofrad
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad
Using structure and sequence based analysis we can engineer proteins to increase their thermal stability.

1 October 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
RSRazieh Salahandish
Razieh Salahandish
AGAli Ghaffarinejad
Ali Ghaffarinejad
SNSeyed Morteza Naghib
Seyed Morteza Naghib
KMKeivan Majidzadeh-A
Keivan Majidzadeh-A
HZHossein Zargartalebi
Hossein Zargartalebi
ASAmir Sanati-Nezhad
Amir Sanati-Nezhad