Jing Zhou

Mr. Jing Zhou

College of Mechanical and Vehicle Engineering, Hunan University, Changsha 410082, China;
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Wen BishengWen Bisheng
Wen Bisheng
Kan LiuKan Liu
Kan Liu
Jing ZhouJing Zhou
Jing Zhou
SZShichao Zhou
Shichao Zhou
Wei HuWei Hu
Wei Hu
QHQing Huang
Qing Huang
A method for real-time estimation of rotor flux linkage of permanent-magnet synchronous machines (PMSMs) under both steady state and free-running conditions is proposed in this paper. At steady state, a method for the estimation of rotor flux linkage is proposed based on the injection of variable-period zero-voltage perturbation, of which the accuracy is irrespective of the influence of voltage-source inverter (VSI) nonlinearity. Moreover, for the estimation of rotor flux linkage under free-running condition, due to system inertia after shutdown or fault in the motor driver, an effective approach using history data recorded at different transients of rotor speeds is developed, which has eliminated the influence of VSI nonlinearity during the modeling process. The proposed two methods are experimentally validated on a down-sized PMSM prototyped for electric vehicle application, which shows good performance for the estimation of rotor flux linkage under both steady state and free-running conditions.

29 January 2021 in World Electric Vehicle Journal
Verified
Journal Article
Open access
PDF file
Jing ZhouJing Zhou
Jing Zhou
Kan LiuKan Liu
Kan Liu
JLJuan Li
Juan Li
LLLongfei Li
Longfei Li
Wei HuWei Hu
Wei Hu
RDRongjun Ding
Rongjun Ding
Due to the nonlinearities of the voltage-source inverter (VSI) in a permanent magnet synchronous machine (PMSM) drive system, there is always an error between the reference voltage and the actual output voltage. To compensate the voltage error, many schemes have been proposed based on the phase current polarity. However, due to factors such as current clamping, measurement noises, and control system delay, the accuracy of the detected current polarity is relatively low, especially when the current is around zero, which would therefore affect the compensation performance. To solve this issue, a deadbeat prediction-based current zero-crossing detection method (DP-CZD) is proposed in this paper. With the proposed method, the measured three-phase currents are replaced by the predicted three-phase currents in terms of the polarity determination, when the absolute value of the phase current is within the threshold range. Compared with the conventional phase current polarity detecting methods, the proposed method can greatly improve the accuracy of detected current polarity due to its smooth transient waveform, and consequently, contributes to the much higher accuracy and lower total harmonic distortion (THD) in the compensation of VSI nonlinearity, which is verified through a prototype surface-mounted PMSM.

24 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
BGbaihui gong
baihui gong
Kan LiuKan Liu
Kan Liu
HLHaozhe Luan
Haozhe Luan
JWJiaming Wu
Jiaming Wu
Jing ZhouJing Zhou
Jing Zhou
HWHuajiang Wu
Huajiang Wu
The phase-shifted full-bridge (PSFB) converter has been widely used in power supply modules due to its simple control and high output power. However, with the market’s increasing demand for higher power sources, the PSFB converter needs to face challenges in increasing its output power level. Compared to redesigning a larger power module or a larger single converter, it will be more cost-effective to achieve a higher power output by paralleling the existing converters. However, due to the manufacturing differences in circuit components, the output imbalance in parallel PSFB converter systems may damage the power modules. Thus, the influence of differences in circuit components is analyzed in this paper, and it is found that the leakage inductance and transformer ratio are the main factors resulting in errors in current sharing control. Consequently, a dynamic hybrid compensator (DHC) is proposed in this paper, that can significantly reduce the error in current sharing control via the compensation of the duty cycle of a slave module. Furthermore, the DHC is verified on an 800 W two-phase PSFB converter, which shows that even when the difference in components is as large as 20%, the proposed method can still reduce the error in current sharing control to less than 2% under both half and full load conditions.

9 June 2025 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
Jing ZhouJing Zhou
Jing Zhou
Kan LiuKan Liu
Kan Liu
YZYue Zhang
Yue Zhang
YCYongdan Chen
Yongdan Chen
Wei HuWei Hu
Wei Hu
XPXiaoyan Peng
Xiaoyan Peng
In this paper, a real-time compensation scheme of the dynamic load position error (DLPE) due to the elastic coupings between the driving motor and load of a two-inertia transmission system (TTS) is proposed, which does not need to install an extra position sensor on load side. Based on the TTS model, the DLPE compensator is derived at first, which can be calculated real time with the aid of pre-estimation of system torsional stiffness and moment of inertia of driving motor. Afterwards, the position of driving motor and calculated DLPE will be used as the position feedback for the load position control. The DLPE due to elastic couplings can be compensated real time with the proposed method. The proposed method is experimentally verified on a two-inertia transmission system driven by a permanent magnet synchronous machine (PMSM), which shows almost zero load position error under both dynamic and steady state tests.

28 April 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HLHaozhe Luan
Haozhe Luan
Kan LiuKan Liu
Kan Liu
LHLiang Han
Liang Han
Wei HuWei Hu
Wei Hu
BGBaihui Gong
Baihui Gong
RDRongjun Ding
Rongjun Ding
In this paper, a secondary side auxiliary currentsharing compensator (ACSC) for the input-parallel outputparallel (IPOP) phase-shift full-bridge (PSFB) converter is proposed, which can ensure balanced current sharing among the parallel converter modules. Moreover, the proposed scheme can minimize the output gain difference among all converter modules according to the dynamic tuning of duty cycles of ACSCs, which has the superiority of normal operation without extra current sensors and information of circuit parameters. To verify the effectiveness of the proposed method, experimental validation is conducted based on the prototype of 900 W three-phase IPOP PSFB converter, proving that the balanced current sharing and a wide range of high efficiency (> 95.5%) can be simultaneously achieved.

2 June 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KLKaiqing Li
Kaiqing Li
Kan LiuKan Liu
Kan Liu
Wei HuWei Hu
Wei Hu
Jing ZhouJing Zhou
Jing Zhou
YCYongdan Chen
Yongdan Chen
XPXiaoyan Peng
Xiaoyan Peng
In this article, a flexible multimode control scheme with variable switching frequency is proposed for parallel interleaved three-phase inverters. Three working modes are designed based on different operation sequence of inverters, corresponding to low, medium, and high power conditions. Since number of alternately controlled inverters is changed according to the load conditions, the principle of current transition is derived by establishing equivalent circuit model. Based on this, current balance strategy is realized by estimating duration of switches. Furthermore, the flexible mode-switching channel based mode-switching strategy is proposed to achieve fast and smooth transition among different modes. In the proposed scheme, only one field-oriented control (FOC) loop is configured while the drive pulses generated from FOC loop are reallocated to parallel legs for power distribution, thus greatly simplifying the control structure of the parallel inverters. The effectiveness of the proposed method is verified on three parallel inverters with three current sensors. Experimental results show that the proposed scheme can achieve both good dynamic and steady-state performances over wide range of switching frequency and output power.