Wei Hu

Dr. Wei Hu

College of Mechanical and Vehicle Engineering, Hunan University, Changsha, Guangdong, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Rui WangRui Wang
Rui Wang
Qiuye SunQiuye Sun
Qiuye Sun
Wei HuWei Hu
Wei Hu
YLYushuai Li
Yushuai Li
Ma DazhongMa Dazhong
Ma Dazhong
Peng WangPeng Wang
Peng Wang
The droop control is an advantageous approach for stand-alone supply systems consisting of multiple batteries, allowing among various inverters without intercommunication. The droop coefficients of batteries always vary with their state-of-charge (SoC) and charge/discharge mode, resulting in small-signal instability. Nevertheless, the existing impedance-based approaches can only assess the droop coefficients stability point, but not the stability region. Therefore, this article proposes a droop coefficients stability region analysis approach. First, the charge/discharge SoC-based droop controlled battery, the P&Q controlled distributed generator and the constant power load are separately discussed. Meanwhile, the state matrix and return-ratio matrix are established, respectively. Furthermore, the novel forbidden region criterion based on the return-ratio matrix is constructed, which reduces conservatism compared with norm-based impedance criteria and partial forbidden region criteria. Such a forbidden region criterion is first switched to the Hurwitz identification problem regarding the equivalent return-ratio matrix. Combined the state matrix and the equivalent return-ratio matrix, the generalized incidence matrix is constructed to simultaneously identify subsystem stability and interactive stability. Based on the generalized incidence matrix, an adaptive step search strategy is proposed to obtain the droop coefficients coordinated stability region. Finally, the simulation and experimental results illustrate the validity of the proposed method.

21 April 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Wei HuWei Hu
Wei Hu
CRChenhui Ruan
Chenhui Ruan
Heng NianHeng Nian
Heng Nian
DSDan Sun
Dan Sun
The zero-sequence loop inherently exists in the structure of three-phase open-end winding permanent-magnet synchronous machine (OW-PMSM) system with common dc bus, which provides the circulating path for zero-sequence current (ZSC) and consequently causes the torque ripple and extra system loss. Besides, the common mode voltage (CMV), which can cause many negative effects, such as the bearing current and the failure of motor bearing, is another concern in the driving system. However, the simultaneous suppression of ZSC and the CMV control of the devices is investigated mainly in the application of induction machine system and multi-phase OW-PMSM system, while it's ignored in the application of three-phase OW-PMSM system, in which the suppression of ZSC is more complex considering the effect of flux linkage harmonic components. On this basis, this paper proposes a strategy which can not only suppress the ZSC but also eliminate the ripple of CMV in three-phase OW-PMSM system. In the proposed method, the suppression of ZSC is achieved by synchronously adjusting the duration time of each phase within every control cycle based on the reference voltage of zero-sequence control loop, which can simplify the conventional re-arrangement-based scheme.

22 November 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Wei HuWei Hu
Wei Hu
Heng NianHeng Nian
Heng Nian
DSDan Sun
Dan Sun
Zero-sequence current (ZSC) is inevitable in the structure of an open-end winding permanent-magnet synchronous machine (OW-PMSM) system with a common dc bus due to the simultaneous existence of the ZSC loop and the zero-sequence voltage (ZSV) caused by the inverters and third electromotive force. To suppress the ZSC, a novel strategy with a reduced switching frequency is proposed in this paper. The main contribution of the proposed method is that the ZSC is suppressed totally with a reduced switching frequency. The duration time of the active voltage vectors is redistributed to generate the reference voltage in a zero-sequence loop, which leads to the suppression of the ZSC. Different from the conventional method, only the active voltage vectors instead of the zero voltage vectors are employed to suppress the ZSC. Consequently, the switching frequency in the modulation process can be reduced. In addition, the effective modulation range of the ZSV is analyzed, which further reveals the relationship among the effective modulation of the ZSV, the modulation index, and the ratio of the third flux linkage component to the fundamental flux linkage component. Finally, the effectiveness of the proposed method is validated by an OW-PMSM experimental setup with a common dc bus. Moreover, the proposed method is experimentally compared with the existing methods.

7 May 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Wei HuWei Hu
Wei Hu
Heng NianHeng Nian
Heng Nian
TZTaiying Zheng
Taiying Zheng
Torque ripple caused by zero-sequence current (ZSC) and relatively high switching frequency severely worsens the operating performance of an open-winding permanent-magnet synchronous machine (OW-PMSM) system with common dc bus. In this paper, a novel q-axis current injection method based on the angle-shift-based voltage distribution is proposed for the OW-PMSM system with common dc bus. With the proposed method, torque ripple caused by ZSC can be counteracted by the torque component generated by the injected q-axis current. Meanwhile, the corresponding modulation range is analyzed to investigate the availability of the proposed method. Moreover, in order to reduce the switching frequency, zero vector (111) is no longer necessary to compensate the zero-sequence component and conventional space vector pulsewidth modulation (PWM) with zero vectors (000) and (111) can be simplified. The switching actions in one PWM period can be reduced from 12 to 8. The comparison of losses shows that this strategy can effectively improve the efficiency under both heavy load and high switching frequencies. Finally, the effectiveness of the proposed method is validated through an OW-PMSM experiment with common dc bus.

26 June 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Wei HuWei Hu
Wei Hu
CRChenhui Ruan
Chenhui Ruan
Heng NianHeng Nian
Heng Nian
DSDan Sun
Dan Sun
This letter proposes a unified modulation strategy for the open-end winding permanent magnet synchronous motor (OW-PMSM) system with common dc bus under the open-phase fault condition. Based on the analysis of the voltage distribution of OW-PMSM under the open-phase fault, two orthogonal voltage vectors among the existing ones are applied to synthesis the reference voltage. In the proposed modulation process, the duration time of the two selected orthogonal voltage vectors is directly obtained and both sector identification and calculation of trigonometric function can be avoided. Furthermore, the arrangement of switching signals is achieved universally according to the switching states of the selected voltage vectors. Thus, the proposed modulation scheme can be greatly simplified, compared with the conventional strategies. The performance of the proposed scheme is validated experimentally in an OW-PMSM system with common dc bus under open-phase fault.

19 April 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Dong WeiDong Wei
Dong Wei
Kan LiuKan Liu
Kan Liu
Wei HuWei Hu
Wei Hu
XPXiaoyan Peng
Xiaoyan Peng
YCYongdan Chen
Yongdan Chen
RDRongjun Ding
Rongjun Ding
Inter-turn short circuit (ITSC) is a common fault in electrical machines, which may result in further devastation to the whole winding and magnets. In this article, a method for real-time residual insulation capacity monitoring of ITSC fault in permanent magnet synchronous machines (PMSMs) is proposed, which is robust to speed/torque variation and independent of machine parameters and extra sensors. It is based on the theory that the ITSC fault initiates as an insulation deterioration among adjacent turns and the fault severity can be described by the residual insulation capacity being relevant to the 2nd harmonic component in the dq -axis currents. Thus, a short-time Adaline-based harmonic extraction method is proposed for the separation of the needed 2nd harmonic component from time-varying current signals, being used as the fault indicator afterward. Finally, the performance of the proposed method is experimentally evaluated on a PMSM and shows quite good performance in fast-tracking and detection of faults in various stages.