Haozhe Luan

Haozhe Luan


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
JWJianbo Wang
Jianbo Wang
Kan LiuKan Liu
Kan Liu
Dong WeiDong Wei
Dong Wei
YCYongdan Chen
Yongdan Chen
JCJinya Chen
Jinya Chen
JZJing Zhou
Jing Zhou
In this article, a multielectrical signal fusion method based on the rotor speed and stator current is investigated for bearing fault diagnosis of permanent magnet synchronous machines (PMSMs) under variable speed conditions. This method can achieve low-cost and real-time fault diagnosis by using directly measured rotor speed and stator current signals from the drive machine of the mechatronics system. First, the fault feature harmonic can be extracted from the rotor speed signal, and the instantaneous phase is estimated using the stator current of PMSMs. The time-domain fault feature harmonic is then resampled on the angle domain using a high-precision accumulative angle calculated by the instantaneous phase. Finally, the fault type can be diagnosed by the fault indicator in the envelope spectrum of the resampled signal. Furthermore, experimental validations are conducted on the PMSM-drive-system-based bearing fault diagnosis platform. The results indicate that the proposed method can accurately extract fault features to diagnose the bearing faults under variable speed conditions without extra sensors.

13 November 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LGLi Gao
Li Gao
Kan LiuKan Liu
Kan Liu
YCYongdan Chen
Yongdan Chen
HLHaozhe Luan
Haozhe Luan
SZShichao Zhou
Shichao Zhou
CHChao Huang
Chao Huang
In this paper, a variable-gain LLC converter with a series-parallel hybrid switch-controlled capacitor (SCC) network is proposed. By tuning the duty cycle of two controlled switches, the resonant capacitance of converter can be regulated and will slightly shift the parameters of resonant tank. Meanwhile, the added switches will be turned on at the zero-crossing point of resonant current to guarantee soft switching. Besides, a mode switching scheme based on the modulation of both switching frequency and capacitance is proposed, by which a group of converter voltage gain curves can be obtained and consequently expands its operation range. In order to verify the effectiveness of proposed design, a 250W prototype converter is designed and tested under different loads and modes. It shows that the proposed design can retain the characteristics of conventional LLC converter, such as soft switching and high efficiency, while it can achieve a wider range of input voltage and a robust control of output voltage against disturbances from input voltage.

9 April 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
JWJianbo Wang
Jianbo Wang
YCYongdan Chen
Yongdan Chen
Kan LiuKan Liu
Kan Liu
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
Dong WeiDong Wei
Dong Wei
HLHaozhe Luan
Haozhe Luan
The analysis of electrical signal signatures has become the state-of-the-art solution in bearing fault diagnosis of permanent magnet synchronous machines (PMSMs). However, signatures in electrical signals of PMSMs are easy to vary with the bandwidths of PI controllers, which will affect the accuracy of fault diagnosis. Aiming to solve this issue, a bearing fault diagnosis method considering the interaction among controller bandwidths and electrical signals has been proposed in this paper, which has superior performance in automatically diagnosing various fault patterns. Firstly, it uses the variational mode decomposition to extract the fault harmonic components from electrical signals under various controller bandwidths, by which the fault features can be obtained afterwards. The above fault features under various controller bandwidths are then employed as inputs for the training of a variable prediction model (VPM). The VPM after training will be finally used for real-time diagnosing the patterns of bearing faults. The proposed method is tested on PMSMs equipped with three types of faulty bearings and shows good accuracy in recognizing various fault patterns under uncertain controller bandwidths.

15 July 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
JWJianbo Wang
Jianbo Wang
YCYongdan Chen
Yongdan Chen
Kan LiuKan Liu
Kan Liu
Dong WeiDong Wei
Dong Wei
SZShichao Zhou
Shichao Zhou
HCHuaqiang Cai
Huaqiang Cai
This paper proposes a comb filter-based noise cancellation method to mitigate the impact of dominant components and extract fault features in the electrical signals of permanent magnet synchronous machines (PMSMs) for bearing fault diagnosis. The parameters of the comb filter are determined by the rotor speed to effectively eliminate the noise inherent in the electrical signals being analyzed, hence extracting the fault harmonics. The diagnosis of bearing defects is afterward achieved by employing spectrum analysis of the filtered signals. Notably, the proposed method does not necessitate complex signal transformation and decomposition, hence enabling efficient fault diagnosis. The effectiveness of the proposed method is evaluated through signature analysis of rotor speed, currents, and voltage signals in PMSMs that are equipped with three different types of faulty bearings, even under lower rotor speed and load disturbance conditions. Moreover, a comparative analysis conducted between the proposed method and existing solutions reveals its excellent performance in rapidly diagnosing bearing faults.

18 February 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
SZShichao Zhou
Shichao Zhou
Kan LiuKan Liu
Kan Liu
YCYongdan Chen
Yongdan Chen
LGLi Gao
Li Gao
BMBo Ma
Bo Ma
BWBisheng Wen
Bisheng Wen
Due to the difference of common-mode voltage (CMV), the zero-sequence circulating current (ZSCC) becomes a major issue in two paralleled voltage source inverters (VSIs) with a common DC bus. To address this challenge, this paper proposes a minimal ZSCC modulation strategy based on the vector redundancy of paralleled system, which theoretically eliminates the excitation source of ZSCC. Given the redundancy of equivalent vectors, the vectors with zero CMV difference are developed to synthesize the command voltage. Each 60° sector of space vector modulation is further segmented into four subsectors. Optimal vector sequences in these subsectors are designed according to the rules of preventing line-to-line voltage reversal and minimizing switching actions. And the implementation of the proposed method is thoroughly investigated including the determination and duty cycle calculation of subsectors. Compared with existing works, the proposed method demonstrates superior performance in suppressing ZSCC. The effectiveness of the proposed method is validated on a test platform fed by two paralleled two-level VSIs.

24 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
BGbaihui gong
baihui gong
Kan LiuKan Liu
Kan Liu
HLHaozhe Luan
Haozhe Luan
JWJiaming Wu
Jiaming Wu
Jing ZhouJing Zhou
Jing Zhou
HWHuajiang Wu
Huajiang Wu
The phase-shifted full-bridge (PSFB) converter has been widely used in power supply modules due to its simple control and high output power. However, with the market’s increasing demand for higher power sources, the PSFB converter needs to face challenges in increasing its output power level. Compared to redesigning a larger power module or a larger single converter, it will be more cost-effective to achieve a higher power output by paralleling the existing converters. However, due to the manufacturing differences in circuit components, the output imbalance in parallel PSFB converter systems may damage the power modules. Thus, the influence of differences in circuit components is analyzed in this paper, and it is found that the leakage inductance and transformer ratio are the main factors resulting in errors in current sharing control. Consequently, a dynamic hybrid compensator (DHC) is proposed in this paper, that can significantly reduce the error in current sharing control via the compensation of the duty cycle of a slave module. Furthermore, the DHC is verified on an 800 W two-phase PSFB converter, which shows that even when the difference in components is as large as 20%, the proposed method can still reduce the error in current sharing control to less than 2% under both half and full load conditions.