Surgical mesh products made from polypropylene (PP) have been extensively used in the treatment of stress urinary incontinence, pelvic organ prolapse and other conditions. Since the onset of the use of such implants, major complications have been reported. Mesh erosion, where neighbouring tissues are worn from the rubbing of mesh, occurs in a significant number of cases. However, there is still a lack in literature exploring the mechanics of this phenomenon. In this study, a purpose-built apparatus was used to generate erosion in soft tissue (porcine muscle) through the application of a force and a reciprocating action. Four different commercial products were tested, all made from knitted PP fibres: Monarc™ Gynecare™ and Obtryx™ slings and Sutulene™ mesh sheet material. A PP suture and three PP sheets with different edge roughness were also tested. Large differences were found in the erosion rates. Significantly, we found that meshes in which the edge had been formed using heat to cause partial melting gave much higher rates of erosion than mechanically cut edges. Heat-formed edges tended to retain their shape whilst mechanically cut edges degraded by unravelling. Several features of the mesh edge appear to be significant, including roughness, flexibility and the tendency to degrade. Constant load (non-reciprocating) tests were also carried out, revealing that creep can also cause erosion. These findings have significance for the design of surgical mesh products to minimise their adverse effects.
18 October 2024 in Advanced Materials Technologies
Biological and mechanical mismatches between engineered scaffolds and native tissues poses widespread challenges for tissue restoration. Native‐like anisotropy is a critical characteristic for functional tissue replacements, yet it is an often‐overlooked aspect when designing new scaffolds. In this study, fiber‐reinforced tubular scaffolds are developed, mimicking the anisotropic characteristics of natural tissues, using native‐like silk fibroin. To predict the mechanical behavior of these innovative scaffolds, a mathematical model is employed, utilizing the properties of the scaffolds’ constituent materials, and experimentally validated through tensile testing. This approach addresses significant challenges in the design of new scaffold implants by enabling to efficiently predict the performance of several configurations, narrowing down the experimental research space. The proposed platform constitutes an appealing tool for the development of clinically relevant tissue‐equivalents.
Tissue‐mimetic scaffolds capable of actuating in response to environmental stimuli have great potential in soft robotics, especially if controllable at the molecular level. Elastin‐like recombinamers (ELRs) are biopolymers derived from natural tropoelastin intrinsically capable of responding to exogenous factors (e.g., pH, salt or temperature). A well‐designed and properly manufactured ELR scaffold should i) respond and adapt (actuate) according to external stimuli and ii) exhibit elastic properties to accommodate biomimetic actuation. However, current concepts typically use isotropic matrices, leading to isometric dimensional changes. In contrast, anisotropic actuation, a key feature in biological tissues at micro‐ and macroscopic level, allows directionally preferred responses but demands advanced design parallelled by an adequate fabrication scheme. Here, this challenge is addressed, by developing anisotropic elastin‐like scaffolds for directional, stimuli‐triggered actuation. Specifically, a fiber‐reinforced, elastin‐like tubular scaffold is developed with the capacity to actuate in an anisotropic and reversible manner in response to changes in solvent or temperature. Both the anisotropy and the degree of actuation can be efficiently controlled by changing the angle of the fiber‐reinforcement engineered within the elastin‐like matrix. The selection of the material and the straightforward fabrication make this scaffold versatile for applications that blends both soft robotics and tissue engineering.
Mesh erosion is a phenomenon whereby soft tissue becomes damaged as a result of contact with implants made from surgical mesh, a fabric-like material consisting of fibers of polypropylene or other polymers. This paper describes the design and construction of a testing machine to generate mesh erosion in vitro. A sample of mesh in the form of a 10 mm wide tape is pressed against soft tissue (porcine muscle) with a given force, and a given reciprocating movement is applied between the mesh and the tissue. To demonstrate the capabilities of the equipment, we measured erosion using the same mesh and tissue type, varying the applied force and the reciprocating stroke length, including zero strokes (i.e., static loading). For comparison, we also tested four other samples of polypropylene with different edge characteristics. Analysis of the results suggests the existence of three different erosion mechanisms: cutting, wear and creep. It is concluded that the equipment provides a useful and realistic simulation of mesh erosion, a phenomenon that is of great clinical significance and merits further study.
1 February 2022 in Journal of the Mechanical Behavior of Biomedical Materials