Gordon O'Brien

Mr. Gordon O'Brien

Department of Mechanical Manufacturing and Biomedical Engineering, Trinity College

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Acoustics
Verified
Journal Article
Open access
PDF file
DDDaniel Deery
Daniel Deery
LFLara Flanagan
Lara Flanagan
GOGordon O'Brien
Gordon O'Brien
HRHenry J. Rice
Henry J. Rice
John KennedyJohn Kennedy
John Kennedy
Significant potential for acoustic metamaterials to provide a breakthrough in sound attenuation has been unlocked in recent times due to advancements in additive manufacturing techniques. These materials allow the targeting of specific frequencies for sound attenuation. To date, acoustic metamaterials have not been demonstrated in a commercial automotive silencer for performance enhancement. A significant obstacle to the practical use of acoustic metamaterials is the need for low cost and efficient modelling strategies in the design phase. This study investigates the effect of acoustic metamaterials within a representative automotive silencer. The acoustic metamaterial design is achieved using a combination of analytical and finite element models, validated by experiment. The acoustic metamaterial is then compared with commonly used techniques in the silencer industry to gauge the effectiveness of the acoustic metamaterials. COMSOL simulations were used to validate the developed test rig and were compared to experimental results which were obtained using the two-load transmission loss test method. Through this testing method, the implementation of a labyrinthine metamaterial cylinder proved to be a significant improvement in transmission loss within the silencer, with an increase in transmission loss of 40 dB at 1500 Hz. The research has successfully shown that acoustic metamaterials can be used in practical settings, such as an automotive silencer, to improve the overall sound attenuating performance. The described analytical model demonstrates the potential for industrially relevant low cost design tools.

17 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
ASAmanda Schmidt
Amanda Schmidt
GOGordon O'Brien
Gordon O'Brien
DTDavid Taylor
David Taylor
Mesh erosion is a phenomenon whereby soft tissue becomes damaged as a result of contact with implants made from surgical mesh, a fabric-like material consisting of fibers of polypropylene or other polymers. This paper describes the design and construction of a testing machine to generate mesh erosion in vitro. A sample of mesh in the form of a 10 mm wide tape is pressed against soft tissue (porcine muscle) with a given force, and a given reciprocating movement is applied between the mesh and the tissue. To demonstrate the capabilities of the equipment, we measured erosion using the same mesh and tissue type, varying the applied force and the reciprocating stroke length, including zero strokes (i.e., static loading). For comparison, we also tested four other samples of polypropylene with different edge characteristics. Analysis of the results suggests the existence of three different erosion mechanisms: cutting, wear and creep. It is concluded that the equipment provides a useful and realistic simulation of mesh erosion, a phenomenon that is of great clinical significance and merits further study.