This research proposes a 3D internal visualization using ultrasonic pulse-echo tomography technique to evaluate accurately the state of concrete structures for their efficient maintenance within a limited budget. Synthetic aperture focusing technique (SAFT) is used as a post-processing algorithm to manipulate the data measured by the ultrasonic pulse-echo technique. Multifaceted measurements improve the weakness of the existing ultrasonic pulse-echo tomography technique that cannot identify the area beyond a reflector as well as the area located far away from measuring surfaces. The application of apodization factor, pulse peak delay calibration and elimination of trivial response not only complements the weaknesses of the SAFT algorithm but also improves the accuracy of the SAFT algorithm. The results show that the proposed method reduces the unnecessary surface noise and improves the expressiveness of the reflector’s boundaries on the resulting images. It is expected that the proposed 3D internal visualization technique will provide a useful non-destructive evaluation tool in combination with another structure evaluation method.
An ultrasonic array device like the A1040 MIRA is used to non-destructively visualize the inside of concrete structures. A data set acquired by the ultrasonic array device is so unfocused that an image reconstruction algorithm is required to transform the data set into an understandable image. The image reconstruction algorithm like total focusing method exploits the time-of-flight of an ultrasonic pulse when focusing the image. While a high frequency ultrasonic pulse barely affects the accuracy of results, a low frequency ultrasonic pulse with a long wavelength causes an overall sagging of the resulting image around half wavelength of the pulse, which results in a poor quality of results. In this research, a modified total focusing method called pulse peak delay-total focusing method is proposed to calibrate the sagging in the resulting images due to the long wavelength of the pulse. The simulation of an ultrasonic array signal is implemented to validate the proposed method. The experimental results are compared with the simulation results to validate the proposed method. The simulation using the proposed method shows good agreement with experimental results. Analysis of results using potential damage curve and array performance indicator shows that the proposed method allows the higher accuracy, as well as the increased resolution of resulting images.
A non-destructive evaluation method is proposed to identify the sectional loss of the external tendon of prestressed concrete structures by detecting the change of the magnetic flux in the external tendon exposed to a magnetic field. The method uses a solenoid-shaped device with two coils: a primary coil for producing magnetic field and secondary coil for damage detection, wrapping the external tendon. A current applied to the primary coil in the device causes the magnetic field. Then, the change in the magnetic flux by the damage in the external tendon is detected by the variation of the voltage in the secondary coil in the device as the device moves along the tendon. An alternating current is applied to the primary coil to minimize the effect of the moving speed of the device. As a result, the damaged area can be detected with a low-level energy current. In addition, a wrapping solenoid-shaped device that is easy to disassemble and assemble was developed for in situ inspection. The measured signal from the secondary coil has a sinusoidal form with the same frequency as the applied current to the primary coil, and the peak curve of the measured signal provides enough information to detect the damage. It is shown that the proposed method can quantitatively identify one or multiple damaged-tendon locations as well as damages of at least 2 cm.