The advances of high-frequency vacuum electron devices (VEDs) in China are reviewed in this paper, including traveling-wave tubes (TWTs) based on novel slow-wave structures (SWSs), high harmonic TWT amplifier, gyrotrons, Smith-Purcell (SP) radiation sources, surface plasmon polaritons (SPPs) sources, and terahertz (THz) radiation sources in ion-focused beam-plasma system. As one of the most widely used VEDs, TWTs based on folded type SWSs, planar SWSs, and grating type SWSs are studied theoretically and experimentally from Ka-band to R-band. Using folded type SWSs, two TWT amplifiers are developed. As high-power millimeter wave and THz wave sources, gyrotron TWTs, gyrotron oscillators, and gyroklystrons are presented. Moreover, this paper shows SP radiation sources, SPPs sources, and THz radiation sources in ion-focused beam-plasma system open good prospects for developing high-frequency VEDs with new mechanisms, which undoubtedly brings about innovative changes for the development of VEDs.
17 May 2019 in IEEE Transactions on Plasma Science
This paper puts forward a novel dual-beam overmoded folded waveguide (FW) slow-wave structure (SWS), which is loaded with photonic crystals. In this novel structure, the two electron beams pass through the small gaps between the photonic crystal structures and the FW; the dimension of the FW is twice larger than that of the fundamental mode structure. The novel dual-beam photonic crystal overmoded FW traveling-wave tube (TWT) is proposed on the basis of the SWS. And, a mode converter is introduced to achieve the connection between the SWS and the input/output structure, and the mode transformation. At the operating voltage of 21.2 kV and the operating current of 320 mA, the proposed TWT can generate 128 W of output power at 220 GHz, and its 3-dB bandwidth is 7 GHz, ranging from 216 to 223 GHz.
A 500 GHz TE 85 mode continuously frequency-tunable gyrotron has been designed, fabricated and investigated experimentally. In the experiment, the gyrotron operates at the second cyclotron harmonic stably. The operating frequency is tuned by means of adjusting the operating magnetic field or the beam energy. The variation of the output power is also investigated. It is found that when the operating magnetic field is changed, the frequency-tuning range is much bigger than that when the beam energy is changed.
1 August 2022 in IEEE Transactions on Electron Devices
In this article, the experimental investigations on a 263-GHz gyrotron are presented. With the change of the operating magnetic field and the beam energy, the operating frequency is adjusted and the output power is also varied. It is found that when the operating magnetic field changes from 9.59 to 9.82 T at a fixed operating voltage of 20 kV and a beam current of 0.8 A, the operating frequency increases from 263.39 to 264.84 GHz, the frequency-tuning range is about 1.45 GHz, and the output power is from 26 to 463 W. When the operating voltage increases from 14.4 to 22.2 kV at a fixed operating magnetic field of 9.65 T, the operating frequency decreases from 263.68 to 263.40 GHz, the frequency-tuning range is 0.28 GHz, and the output power changes from 52 to 424 W. When the operating magnetic field is fixed at 9.65 T and the operating voltage is fixed at 20 kV, but the beam current increases from 120 to 880 mA, the output power increases from 21 to 277 W, the operating frequency increases from 263.396 to 263.425 GHz, and the frequency-tunable range is 0.029 GHz. The effects of the axial position of the gyrotron in the superconducting magnet system on the operating frequency, the frequency-tuning range, and the output power are also investigated experimentally. When the beam current is increased, the nonstationary phenomenon is observed.
12 November 2013 in IEEE Transactions on Electron Devices
The resonant frequency, the diffractive quality factor, and the mode competition in the coaxial gyrotron cavity with a tapered inner rod have been investigated. The resonant frequency and the diffractive quality factor can be adjusted by changing the tilt angle and the radius of the tapered inner rod. When the inner rod radius is far smaller than the caustic radius of the given mode, the resonant frequency and the diffractive quality factor are hardly affected by the tilt angle of the tapered inner rod; the resonant frequency increases slightly but the diffractive quality factor increases noticeably with the increase of the tilt angle of the tapered inner rod when the inner rod radius is a little smaller than the caustic one; the resonant frequency and the diffractive quality factor decrease with the increase of the tilt angle of the tapered inner rod when the inner rod radius is larger than the caustic one. The mode competition can be improved with an appropriate design of the tilt angle and the radius of the tapered inner rod in a coaxial gyrotron cavity with a tapered inner rod.
9 March 2018 in IEEE Transactions on Electron Devices
The effect of the electron beam quality, including the variation of the velocity spread, the guiding center radius spread, and the pitch factor when the operating frequency of a 250-GHz TE₅₂ mode continuously frequency-tunable gyrotron used for dynamic nuclear polarization (DNP) enhanced nuclear magnetic resonance (NMR) spectroscopy is tuned by changing the operating voltage V₀ or the operating magnetic field B₀, on the operating frequency, the frequency-tunable range and the beam-wave interaction efficiency, has been studied based on a self-consistent nonlinear beam-wave interaction theory. It is found that the velocity spread changes from 2.2% to 7.3% and the guiding center radius spread varies from 0.6% to 1.5%, when the operating voltage V₀ changes between 8 and 15 kV at an operating magnetic field of 9.24 T, the velocity spread varies from 4.1% to 6% and the guiding center radius spread changes from 0.8% to 1.4%, when the operating magnetic field B₀ changes between 9 and 9.3 T at an operating voltage of 10.1 kV. The variation of the velocity spread and guiding center radius spread with respect to the operating voltage or the magnetic field have a significant effect on the beam-wave interaction efficiency and the frequency-tunable range of the 250-GHz TE₅₂ mode continuously frequency-tunable DNP/NMR gyrotron, and the effect of the variation of the velocity spread and the guiding center radius spread should be taken into account in a frequency-tunable gyrotron design.