Jichao Han

Dr. Jichao Han


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Jichao HanJichao Han
Jichao Han
BGBaojun Ge
Baojun Ge
WLWeili Li
Weili Li
Press plates are widely used in the end region of turbogenerators. However, due to the effect of magnetic field leakage from the end region, the eddy current losses of the copper screen and press plate will result in the copper screen and press plate having a high temperature under the rated load condition. In this paper, the influence of the magnetic permeability of the press plate on losses and temperature of the end region is researched in turbogenerators. Three-dimensional (3-D) fluid and thermal mathematic and physical models of the turbogenerator end region are established. Under different magnetic permeability values of the press plate, a 3-D transient electromagnetic field in the turbogenerator end region is calculated, and the obtained losses of the end parts are treated as heat sources. Fluid network equations are calculated, and the obtained fluid velocity and pressure values are applied to the end region as boundary conditions. After solving the fluid and thermal equations, fluid velocity around the surface of the end parts is obtained under the rated load condition. The temperature distribution of the end parts is determined for different magnetic permeability values of the press plate. The calculated temperature results agree well with the test data.

8 April 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Jichao HanJichao Han
Jichao Han
XBXizhao Bian
Xizhao Bian
DGDongxin Guo
Dongxin Guo
HQHaiming Qi
Haiming Qi
BGBao Jun Ge
Bao Jun Ge
The spoke-type interior permanent magnet synchronous motor (STIPMSM) is used in the drive systems of electric heavy-duty truck. The drive motors are prone to the overload operation when the electric heavy-duty truck climbs a slope or operates under the heavy load. The reliability of motor is a challenge. The sustained overload capacity is an important index of STIPMSM performance. An improved multi-objective nonlinear coupled iterative calculation method for STIPMSM is proposed, which can accurately calculate the performance changes of STIPMSM under different overload conditions. The nonlinearity of the magnetic circuit and the influence of the external conditions on the material performance are considered in this method. A 650kW STIPMSM is studied. The multi-objective nonlinear coupled iterative calculation method is applied to calculate the different overload conditions. The final multi-objective convergence of physical quantities is achieved. The change of electromagnetic field and harmonics is analyzed under different load rates. A method based on nonlinear fitting for maximum sustained overload (MSO) prediction of STIPMSM is proposed. The predicted MSO operating conditions are calculated. The calculated results are agreement with the predicted results. Experiments are conducted on the STIPMSM prototype under different operating conditions. The accuracy of the calculation method is verified.

12 June 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Jichao HanJichao Han
Jichao Han
PZPing Zheng
Ping Zheng
YSYutian Sun
Yutian Sun
BGBaojun Ge
Baojun Ge
WLWeili Li
Weili Li
To investigate the influence of different electric shield materials on the temperature distribution in the turbogenerator end region, 330 MW water–hydrogen–hydrogen-cooled turbogenerator is considered in this study. Mathematical and physical models of the three-dimensional transient electromagnetic field in the turbogenerator end region are established. The magnetic density distribution and the losses of end parts are obtained with different electric shield materials. The loss values obtained from 3-D transient electromagnetic field calculations with different electric shield materials are applied to the end parts as heat sources. Pressure and fluid velocity values from flow network calculations are applied to the end region as boundary conditions for the fluid and thermal coupling analysis. In addition, 3-D fluid and thermal coupling model of the turbogenerator end region is established. The distributions of the surface heat transfer coefficient on the inner and outer surfaces of the electric shield are determined with different electric shield materials. Temperature distributions of the stator-end copper winding, finger plate, clamping plate, and electric shield in the turbogenerator end region are investigated with different electric shield materials. The calculated temperature results for the electric shield are compared with measured values, and the calculated results agree well with the measured values.

28 July 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Jichao HanJichao Han
Jichao Han
BGBaojun Ge
Baojun Ge
DTDajun Tao
Dajun Tao
WLWeili Li
Weili Li
In order to study the influence of different cooling mediums on the fluid velocity and the temperature distribution of end parts in the turbogenerator end region, a 330-MW turbogenerator is analyzed. Three-dimensional fluid-thermal coupling analysis model of the turbogenerator end region is given. When the different cooling mediums are used, fluid velocity of fan inlet and pressure values of end-region outlet from the flow network calculation are applied to the end region as boundary conditions, and the losses from 3-D transient electromagnetic field calculation are applied to the end parts as heat sources in the fluid-thermal coupling field. The fluid field and temperature field in the turbogenerator end region are calculated using the hydrogen and air as cooling medium, respectively. Fluid velocity and temperature of end parts in the turbogenerator end region are compared when the different cooling mediums are used. When the hydrogen is used as the cooling medium, comparing the calculated temperature results with the test values, the calculated temperature results match well with test values. These will provide a reference for the ventilation cooling design of large turbogenerator.

24 April 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
BGBao Jun Ge
Bao Jun Ge
XXXiao Xu
Xiao Xu
DTdajun tao
dajun tao
Jichao HanJichao Han
Jichao Han
LWLikun Wang
Likun Wang
The driving motor for the cooling medium in a high-temperature gas-cooled reactor is crucial for coolant circulation in the reactor. This study proposes a method for calculating the gas friction loss using Bernoulli's equation to study its effect on temperature rise in the motor. The ventilation network model of the motor was developed using the fluid network method, and a three-dimensional mathematical model of the stator was established by considering the relationships between fluid velocity, temperature, and gas friction loss. The results of the ventilation system calculations were applied to the physical model as boundary conditions, and the distribution of the stator temperature was determined using the finite volume method. The effect of the change in stator ventilation structure on the gas friction loss distribution was studied. The calculated friction losses agreed with the values obtained using the empirical formula for gas friction loss.

24 February 2021 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
Jichao HanJichao Han
Jichao Han
DJDong Jiechen
Dong Jiechen
YWYang Wang
Yang Wang
CWChao Wang
Chao Wang
BGBaojun Ge
Baojun Ge
WLWeili Li
Weili Li
Extension lengths of the stator and rotor end windings will obviously affect the electromagnetic field, fluid flow, and temperature of end components in the end zone of large water-hydrogen-hydrogen cooled turbine generator. In this paper, a 330 MW water-hydrogen-hydrogen cooled turbine generator is analyzed. Flow network of this turbine generator is established. The fluid velocity and the pressure (boundary conditions) are obtained at the different positions of this turbine generator after solving the equations of flow network. Three-dimensional transient electromagnetic field is calculated in the turbine generator end zone. The leakage magnetic field and the losses (heat source) of end components are determined in the turbine generator end zone under the different lengths of stator and rotor end winding extension. Based on these results, three-dimensional fluid-thermal coupled model is given in the end zone. The distribution of complex fluid velocity in the turbine generator end zone is determined. The temperature distribution of the stator end winding, clamp plate, electric screen, and finger plate is studied under the different lengths of stator and rotor end winding extension. The calculated temperature results agree well with the measured values.