dajun tao

Prof. dajun tao


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2016 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
JHJichao Han
Jichao Han
BGBao Jun Ge
Bao Jun Ge
DTdajun tao
dajun tao
WLWeili Li
Weili Li
In order to study the influence of the cooling fluid parameter on the fluid flow and end part temperature in the end region of the large turbogenerator, a 330-MW water-hydrogen-hydrogen cooled turbogenerator is analyzed. The fluid velocity and pressure values from the flow network calculations are applied to the end region as boundary conditions and the losses obtained from 3-D transient electromagnetic field calculations are applied to the end parts as heat sources in the fluid and thermal coupling analysis. After solving the fluid and thermal equations of fluid-solid conjugated heat transfer, the fluid velocity and end part temperature in the turbogenerator end region are gained under the different cooling fluid parameters. The influence of different fluid velocities and fluid temperatures in the water pipe inlet, and in the fan inlet on the fluid flow and end part temperature in the turbogenerator end region is researched. The calculation results of copper shield temperature are compared with the measured values. The calculation results coincident well with the measured values. These provide the important reference for better cooling turbogenerator end region.

22 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
DTdajun tao
dajun tao
KZKai Liang Zhou
Kai Liang Zhou
FLFei Lv
Fei Lv
QDQingpeng Dou
Qingpeng Dou
JWJianxiao Wu
Jianxiao Wu
JZJibin Zou
Jibin Zou
This study focuses on the core losses in the stator region of high-speed permanent magnet synchronous motors, magnetic field characteristics in the load region, and variations in iron losses caused by changes in these areas. A two-pole 120 kW high-speed permanent magnet synchronous motor is used as the object of study, and a two-dimensional transient electromagnetic field-variable load circuit combined calculation model is established. Based on electromagnetic field theory, the electromagnetic field of the high-speed permanent magnet synchronous motor under multi-load conditions is calculated using the time-stepping finite element method. The magnetic field distribution of the high-speed permanent magnet synchronous motor under a multi-load condition is obtained, and the variations in iron core losses in different parts of the motor under multi-load conditions are further analyzed. The calculation results show that most of the stator iron core losses are dissipated in the stator yoke. The stator yoke iron loss under the no-load condition exceeds 70% of the total stator iron core loss. The stator yoke iron loss under rated operation conditions exceeds 50% of the total stator iron core loss. The stator loss under rated load operation conditions is higher than that under no-load operation. These observations are sufficient to demonstrate that the running status of high-speed motors is closely related to the stator iron losses, which have significance in determining the reasonable yoke structure of high-speed and high-power motors and the cooling methods of motor stators.

24 April 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
BGBao Jun Ge
Bao Jun Ge
XXXiao Xu
Xiao Xu
DTdajun tao
dajun tao
Jichao HanJichao Han
Jichao Han
LWLikun Wang
Likun Wang
The driving motor for the cooling medium in a high-temperature gas-cooled reactor is crucial for coolant circulation in the reactor. This study proposes a method for calculating the gas friction loss using Bernoulli's equation to study its effect on temperature rise in the motor. The ventilation network model of the motor was developed using the fluid network method, and a three-dimensional mathematical model of the stator was established by considering the relationships between fluid velocity, temperature, and gas friction loss. The results of the ventilation system calculations were applied to the physical model as boundary conditions, and the distribution of the stator temperature was determined using the finite volume method. The effect of the change in stator ventilation structure on the gas friction loss distribution was studied. The calculated friction losses agreed with the values obtained using the empirical formula for gas friction loss.

25 May 2023 in IEEE Access
Verified
Journal Article
Open access
HJHu Jinming
Hu Jinming
DTdajun tao
dajun tao
SYSun Yutian
Sun Yutian
ZCZhang Chunli
Zhang Chunli
LGLi Guifen
Li Guifen
HGHu Gang
Hu Gang
Large-scale variable-speed pumped storage motor-generator adopts rotor winding AC excitation technology, which can adapt to the regulation requirements of wide speed range and wide power variation. In order to adapt to the demand of dynamic change of multiple operating conditions of pumped storage motor-generator, combined with the characteristics of bi-directional energy flow of variable speed motor-generator, and considering the complex control strategy due to its two operating modes of power generation and electric power, it is the basis to realize the stable operation of the system to clarify the constraint law affecting the electrical quantity of motor-generator under different operating conditions. In this paper, the mathematical model of variable speed pumped storage motor is established by using the magnetic field positioning vector control technology, and the mathematical model of variable speed pumped storage motor is derived to analyze the operating characteristics of the motor. The model is used to calculate and analyze the electrical quantities during the speed regulation, active power regulation and reactive power regulation of the power motor, and to investigate the changes of electrical quantities such as stator and rotor current, rotor voltage, rotor active power, rotor reactive power and stator power angle during the change of working conditions. The accuracy of the mathematical model was verified by comparison using a 10MW prototype test. It is a necessary theoretical reference for the analysis of variable speed pumped storage motor-generator operating conditions.

15 March 2024 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
DTdajun tao
dajun tao
BPBo Pan
Bo Pan
KZKailiang Zhou
Kailiang Zhou
JHJichao Han
Jichao Han
PLPeng Lin
Peng Lin
BGBaojun Ge
Baojun Ge

21 September 2026 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
DTdajun tao
dajun tao
SZShan Zhao
Shan Zhao
HWHaixiang Wang
Haixiang Wang
JZJie Zhou
Jie Zhou
JXJiyuan Xu
Jiyuan Xu