In this paper, a series of Na2SO4·10H2O–KCl eutectic mixtures were prepared by adding different mass fractions of KCl (1 wt.%, 3 wt.%, 5 wt.%, or 7 wt.%) to Na2SO4·10H2O. Polyacrylamide (PAM) was proposed as the thickener, sodium tetraborate decahydrate (STD) was proposed as the nucleating agent, and expanded graphite (EG) was proposed as the high thermal conductivity medium for Na2SO4·10H2O–5 wt.% KCl eutectics. The results showed that in Na2SO4·10H2O–5 wt.% KCl eutectics with 5 wt.% PAM and 5 wt.% STD, almost no phase separation occurred, and the degree of supercooling was reduced to 0.4 °C. The thermal performance of Na2SO4·10H2O–5 wt.% KCl composite phase change materials (CPCMs) with varying contents of EG was explored. The results showed that EG could improve the thermal conductivity effectively and that the mass fraction of EG should be no more than 3%, otherwise the crystallization value and supercooling would deteriorate. The thermal reliability of the Na2SO4·10H2O–5 wt.% KCl eutectic CPCMs containing 5 wt.% PAM, 5 wt.% STD, and 3 wt.% EG was investigated, mainly through the ambient temperature, thermal cycling test, and TGA analysis. The results demonstrated that these CPCMs showed perfect thermal reliability.
Intermittent operation can improve the coefficient of performance (COP) of a ground source heat pump (GSHP) system. In this paper, an analytical solution to analyze the geo-temperature restoration performance under intermittent operation of borehole heat exchanger (BHE) fields is established. For this purpose, the moving finite line source model is combined with the g-function and the superposition principle. The model takes into account the heat transfer along the borehole, thermal interference between BHEs, and the influence of groundwater flow. The accuracy of the model is validated through comparison with an experiment carried out under intermittent operation. The model makes it possible to analyze the geo-temperature restoration performance and its influencing factors, such as BHE spacing, heat flow rate, operation mode, and groundwater flow. The main conclusions of this work are as follows. The heat transfer along the borehole should be considered when analyzing the geo-temperature restoration performance. When the BHE spacing increases, the soil temperature change decreases and the heat recovery improves. Therefore, adequate borehole separation distance is essential in the case of a multiple BHE system with unbalanced load. The presence of groundwater flow is associated with interference between the BHEs, which should not be ignored. In the case of long-term operation, the groundwater flow is beneficial to the geo-temperature recovery process, even for downstream BHEs. Finally, a greater groundwater flux leads to a better geo-temperature recovery.
In this paper, the performance of multiple boreholes (multi-BHEs) field is evaluated by considering the groundwater flow. Optimization strategies are presented to mitigate thermal anomalies in the BHEs field. This study shows that groundwater flow greatly improves the heat transfer but causes thermal anomalies downstream. To overcome this problem, a heat transfer model is established for multi-boreholes based on temperature field superposition and moving finite line source model (MFLS). The MFLS multi-boreholes model considers the axial effect and groundwater flow and produces results in agreement with the field tested data of a 4 × 4 boreholes field. Using a dynamic annual load pattern, the long-term performance of the 4 × 4 boreholes field is analyzed. Three dynamic diurnal cooling load models are proposed to evaluate the temperature changes in the underground. The intermittent load model could reduce the local temperature anomalies in downstream tubes. The optimization model for cooling cases for multi-BHEs is elaborated to keep the outlet temperature as low as possible and minimize the extreme temperature anomalies, and by this, ultimately improve the system performance. Furthermore, the temperature variations and thermal anomalies downstream of multi-BHEs are investigated by evaluating the arrangement optimization and load optimization. The results show that the optimization could mitigate thermal anomalies downstream and reduce the rate of temperature imbalance of the BHEs field.
15 June 2017 in Advances in Mechanical Engineering
The heat storage and release capacities of phase change fabric loaded with phase change microcapsules were measured by differential scanning calorimetry (TADSCQ-2000). The melting peak splits into two sub-peaks at 20.83°C and 28.65°C, in which the heat enthalpy was 25.20 J/g, and the melting range was 16.5°C–36.8°C. The heat-conducting performance of the phase change fabric was tested using a YG (B) 606D face-plate thermometer, and the heat preservation coefficient improved to some extent from 1.05% to 32.2% than that of ordinary fabric. Contrast test was carried out for the shirt made of this fabric by the live test method. The results showed that the heat storage capacity of the phase change shirt was not enough to keep the human body maintaining a comfortable temperature for a long time on the occasions with a bigger temperature difference, thus requiring the need of other warm-keeping clothes. This phase change fabric exhibited good effects on maintaining the uniformity of body temperature and improving human comfort and could avoid low-temperature damages to four limbs in cold regions.
17 July 2018 in IOP Conference Series: Earth and Environmental Science
Thermal analysis has been made to find the regional factors affecting the thermal environment of underground engineering. The ground temperature (Tg), ventilating sensible heat ratio (VSHR) of fresh air of 208 major cities in different areas are calculated, and four climate zones including Cold, Dry, Humid, Hot-Humid zones are established for underground engineering. Based on the climate zones map, the energy conservation designs and analysis could be conducted specifically in different areas.