Vincenzo Mallemaci

Mr. Vincenzo Mallemaci

Politecnico di Torino, Department of Energy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Electric Power Systems Research
Verified
Journal Article
Closed access
Vincenzo MallemaciVincenzo Mallemaci
Vincenzo Mallemaci
FMFabio Mandrile
Fabio Mandrile
Sandro RubinoSandro Rubino
Sandro Rubino
Andrea MazzaAndrea Mazza
Andrea Mazza
ECEnrico Carpaneto
Enrico Carpaneto
RBRadu Bojoi
Radu Bojoi

11 July 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
FMFabio Mandrile
Fabio Mandrile
Vincenzo MallemaciVincenzo Mallemaci
Vincenzo Mallemaci
ECEnrico Carpaneto
Enrico Carpaneto
RBRadu Bojoi
Radu Bojoi
Traditional power systems based on synchronous generators often feature low frequency electromechanical oscillations. However, the integration of renewable energy sources through power converters can help tackling this issue. In fact, thanks to the concept of virtual synchronous machine (VSM), it is possible to make the inverters behave as real synchronous machines (SMs). This way, the inverters can be integrated into the grid as traditional SMs and can even outperform them when it comes to damping low frequency oscillations in the power system. To do that, proper damping algorithms must be adopted in the VSM model. Therefore, this paper presents a simple and straightforward damping method for VSMs based on a single lead-lag filter acting on the VSM active power feedback. The proposed method and its integration in the VSM model are described. Moreover, a comparison method and four performance indices are proposed, to better evaluate the performance of the VSM damping methods. Finally, the proposed solution has been experimentally compared to five conventional methods to highlight its features according to the proposed performance indices.

23 January 2021 in World Electric Vehicle Journal
Verified
Journal Article
Open access
PDF file
FMFabio Mandrile
Fabio Mandrile
Davide CittantiDavide Cittanti
Davide Cittanti
Vincenzo MallemaciVincenzo Mallemaci
Vincenzo Mallemaci
RBRadu Bojoi
Radu Bojoi
As a consequence of the exponential growth of the electric vehicle (EV) market, DC fast-charging infrastructure is being rapidly deployed all around the world. Ultra-fast charging (UFC) stations are starting to pose serious challenges to the electric power system operation, mostly due to their high peak power demand and unregulated discontinuous operation. To address these issues, local energy storage can be installed, ensuring a smoother grid power absorption profile and allowing to provide grid-supporting features. In this work, a control solution for the grid-side AC/DC converter of next-generation EV UFC stations is proposed. A virtual synchronous compensator (VSC) control algorithm is implemented, in order to lessen the impact of the charging station on the utility and to provide the full spectrum of grid ancillary services (i.e., frequency regulation, reactive power compensation, harmonic reduction, short circuit current generation, etc.). The proposed control strategy is verified experimentally on a downscaled 15 kVA three-phase inverter, emulating the grid front-end of the charging station.

23 June 2025 in IEEE Access
Verified
Journal Article
Open access
SBStefano Barsali
Stefano Barsali
RBRadu Bojoi
Radu Bojoi
MCMassimo Ceraolo
Massimo Ceraolo
Vincenzo MallemaciVincenzo Mallemaci
Vincenzo Mallemaci
FMFabio Mandrile
Fabio Mandrile
GPGianluca Pasini
Gianluca Pasini
The increasing integration of renewable energy sources and electric vehicles is reshaping distribution networks, calling for advanced control strategies to maintain power system quality, stability and resilience, intended to capacity to maintain stability after severe perturbations. This paper investigates the application of grid-forming (GFM) controls, of two types: droop and virtual synchronous machine, within high-power EV charging stations (HPCS) connected to medium voltage distribution grids. Through detailed simulation of five representative case studies, our results show that GFM converters can sustain isolated grids, support black-start procedures, and provide voltage/frequency regulation. Notably, compared to traditional grid-following inverters, GFM strategies enable HPCS to enhance grid resilience to faults (short circuits considered) and also recovery after blackouts. All models are released as open-source Modelica code, enabling reproducibility and further research. These findings highlight the potential of leveraging charging infrastructure as a flexible, grid-supportive resource in future energy systems. The considered control actions may require bi-directional exchange of power between vehicles and the grid, usually called V2G (vehicle-to-grid) control. However, interesting opportunities also exist in the context of V1G (Smart Charging), where power flow is unidirectional but still controllable. They can in principle used also to interface grid-connected independent battery energy storage systems, but using charging battery-electric vehicles for this purpose has the advantage of exploiting infrastructure already in place (the charging station), adding grid services to it, to enhance its economic competitiveness. The importance of using future charging battery electric vehicles to support grid services is confirmed by the fact that this study has been funded by a research project devoted to this.

14 January 2025 in IEEE Open Journal of Industry Applications
Verified
Journal Article
Open access
ARAlessandro Roveri
Alessandro Roveri
Vincenzo MallemaciVincenzo Mallemaci
Vincenzo Mallemaci
FMFabio Mandrile
Fabio Mandrile
RBRadu Bojoi
Radu Bojoi
The installation of ultra-fast DC charging infrastructures is rapidly increasing worldwide in response to the exponential growing trend of electric vehicle (EV) market. Due to their discontinuous and unpredictable high power absorption, ultra-fast DC chargers pose a challenge for the power system stability. However, their negative impact on the grid operation can be mitigated by making them bidirectional, leveraging the energy stored in EV batteries or in the installed separate storage. Therefore, the power system can exploit this amount of energy to deal with unexpected grid large power imbalances. Moreover, ultra-fast DC chargers can contribute to power system stability by embedding virtual synchronous machine (VSM) algorithms into their AC/DC stage, i.e. the active front-end (AFE) converter unit. The charging station is thus enabled to provide grid services normally in charge of traditional synchronous generators, such as inertial behavior and short circuit current injection during faults to trigger line protections. However, the provision of inertial active power involves a non-negligible reactive power contribution due to the active-reactive power coupling, thus increasing the output current of the converter. Nevertheless, the power coupling also affects the grid support during faults. Indeed, when the AFE injects a short circuit current into the grid, a fluctuating active power can propagate from the grid to the EVs, resulting in a potential cause of degradation for the EV batteries. Therefore, this paper proposes a feedforward-based decoupling solution to guarantee the complete active-reactive power dynamic decoupling while the AFE of an ultra-fast DC charger is providing grid support. Moreover, the proposed method ensures a full-decoupled dynamic response also in case of power references variation during the normal EV charging operation. The proposed decoupling algorithm is experimentally validated on a down-scaled 15 kVA two-level three-phase inverter, emulating the AFE of the ultra-fast DC charger.

13 June 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Vincenzo MallemaciVincenzo Mallemaci
Vincenzo Mallemaci
FMFabio Mandrile
Fabio Mandrile
ECEnrico Carpaneto
Enrico Carpaneto
RBRadu Bojoi
Radu Bojoi
The Simplified Virtual Synchronous Compensator (S–VSC) is a Virtual Synchronous Machine (VSM) solution avail- able in the literature, which operates as a virtual compensator. Previous works demonstrated that it can provide grid services (e.g., inertial behavior, grid support during faults) only in grid– following operation. However, the grid–forming capability of the S–VSC (and in general of a virtual compensator) has never been investigated in the literature. Therefore, this paper proposes an S–VSC model able to operate both in grid–following and in grid– forming configuration. First, the paper validates the small–signal stability of the control algorithm both in grid–mode and island operation through an eigenvalue–based stability analysis. Next, the control algorithm is experimentally validated on a 15 kVA inverter connected to a scaled microgrid. The experimental tests demonstrate that the S–VSC can operate both as grid–following and grid–forming. Moreover, it can seamlessly switch from the grid–connected to the island operation without requiring any communication system. Finally, the grid–forming capability of the S–VSC is experimentally validated even in case of a fault occurrence, thus representing a valid solution for the control of a microgrid.