Power quality and neutral section are two technical problems that hinder the development of electrified railway to high-speed and heavy railway. The co-phase power supply technology is one of the best ways to solve these two technical problems. At present, a V type connection traction transformer is widely used in a power frequency single-phase AC traction power supply system, especially in high-speed railway. In this paper, a new type of co-phase power supply system for electrified railway based on V type connection traction transformer is proposed. One single-phase winding in the V type connection traction transformer is used as main power supply channel, and three ports are used as compensation ports. Neutral section is no longer set with traction substation, and the train is continuously powered through. The independent single-phase Static Var Generators (SVGs) are used to compensate the three-phase imbalance caused by single-phase traction load. When necessary, the power factor can be improved at the same time. The principle, structure, control strategy, and capacity configuration of the technical scheme are analyzed in this paper, and the effectiveness of the scheme is verified by using the measured data of electrified railway. The advantage of this scheme lies in the universal applicability of the V type connection traction transformer, and the flexibility of the SVG device.
The integration of a large number of power electronic converters, such as railway power conditioner (RPC), introduces a series of problems, including harmonic interaction, stability issues, and wideband resonance, into the railway power supply system. To address these challenges, this paper proposes a novel harmonic resonance prevention measure for RPC–network–train interaction system. Firstly, a harmonic model, a parallel resonance impedance model, a series resonance admittance model, and a control stability model are each established for the RPC–network–train interaction system. Secondly, a comprehensive resonance impact factor (CRIF) is proposed to efficiently and accurately identify the key components affecting resonance, and to provide the selection results of optimization parameters for resonance prevention. Next, the initially selected parameters are constrained by the requirements of ripple current, reactive power and stability. Subsequently, the impedance parameters (control parameters and filter parameters) of the RPC are optimized with the objective of reshaping the parallel resonance impedance and series resonance admittance of the RPC–network–train interaction system, ensuring the output current harmonics of RPC meet standards to achieve resonance prevention, while ensuring the stable operation of the RPC. Finally, the proposed resonance prevention measure is verified under both light load and heavy load conditions using a simulation platform and a hardware-in-the-loop experimental platform.
3 December 2024 in IEEE Transactions on Industrial Electronics
Single-phase medium or low voltage distribution networks remain the predominant choice in remote or rural areas, largely due to historical and economic considerations. As economic development progresses, the demand for high-quality three-phase power systems in these regions has increased steadily. To address the challenge of providing three-phase power in remote areas, this article introduces a single-phase to three-phase power flow controller (1PH–3PH PFC) for medium and low voltage distribution networks. The proposed system includes a reverse YNd11 transformer and three half-bridge converters, which have been specifically designed to mitigate grid voltage disturbances, including sags, swells, and harmonics, that may impact loads. Furthermore, the system ensures unit power factor operation while eliminating harmonic currents from the loads. The control strategy incorporates output voltage feedforward and weighted average feedback of the filter inductor current, thereby enhancing system responsiveness. Furthermore, the power flow of apparent and active power under various voltage fluctuation scenarios is analyzed. The proposed scheme is validated through simulation and hardware-in-the-loop experiments. The research results indicate that, in comparison to the UPQC-1Ph–3Ph scheme, the 1PH–3PH PFC solution significantly reduces the converter design capacity, with potential savings of up to 60% of capacity under conditions of a 25% voltage sag.
24 April 2025 in IEEE Transactions on Power Delivery
Railway power conditioner (RPC) is one of the most effective devices in electrified railways for the compensation of negative sequence, reactive power and the utilization of regenerative braking energy. However, the access of RPC will make the railway power supply system exhibit different energy flow modes, which will render the existing principles about wide-band oscillation characteristics opaque (low-frequency oscillation and high-frequency resonance), and increase the difficulty of analysis. The objective of this paper is to present a comprehensive analysis of the wide-band oscillation issue in the RPC-network-train coupling system. Initially, based on the dq decomposition method and mirror-frequency method, a unified impedance model for the system is established considering diverse energy flow modes. Subsequently, the wide-band oscillation distribution is obtained based on the modal decomposition method, thereby revealing the coupling mechanism between the RPC and the existing railway system. The security domain is delineated by further locating the key components affecting the wide-band oscillation based on the sensitivity of the parameters to the frequency and amplitude of the oscillation. Finally, the correctness of the analysis result is verified on the simulation platform and StarSim hardware-in-the-loop experimental platform.
15 October 2025 in Electric Power Systems Research