Energy feedback systems (EFSs) have been widely applied in urban rail transit, and a power flow algorithm and energy-saving evaluation of urban rail power supply systems with EFSs are studied in this paper. First, trains, the reflux system, and traction substations with EFSs are modeled, and the multimode transitions are analyzed, including the maximum power state of the EFS. Then, a modified AC/DC unified power flow algorithm for the DC power supply system, which simplified the DC reflux system is proposed, and a field case study based on a multiple train scenario is presented to validate the algorithm. Furthermore, system-level energy-saving evaluation indexes are applied according to system power flow analysis. When the headway time decreases, the proposed indexes decrease in general mainly as there is more regenerative braking energy absorbed by adjacent trains. The higher the load rates of the step-down substations are, the more daily feedback energy is utilized. When the start voltage of the EFS ranges from 1650 V to 1770 V, the maximum energy-saving rate reaches 11.9%, which occurs when the start voltage is 1670 V. When the no-load voltage is relatively high, the start voltage should not be higher than 1750 V to keep the system running in high efficiency. These results can provide advice for the design and operation of traction power supply systems with EFSs.
Railway power conditioner (RPC) is one of the most effective devices in electrified railways for the compensation of negative sequence, reactive power and the utilization of regenerative braking energy. However, the access of RPC will make the railway power supply system exhibit different energy flow modes, which will render the existing principles about wide-band oscillation characteristics opaque (low-frequency oscillation and high-frequency resonance), and increase the difficulty of analysis. The objective of this paper is to present a comprehensive analysis of the wide-band oscillation issue in the RPC-network-train coupling system. Initially, based on the dq decomposition method and mirror-frequency method, a unified impedance model for the system is established considering diverse energy flow modes. Subsequently, the wide-band oscillation distribution is obtained based on the modal decomposition method, thereby revealing the coupling mechanism between the RPC and the existing railway system. The security domain is delineated by further locating the key components affecting the wide-band oscillation based on the sensitivity of the parameters to the frequency and amplitude of the oscillation. Finally, the correctness of the analysis result is verified on the simulation platform and StarSim hardware-in-the-loop experimental platform.
Purpose: The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network. This paper aims to study the scheme composition and power supply distance (PSD) of the scheme.Design/methodology/approach: Based on the structure of parallel traction network (referred to as “cable traction network (CTN)”), the power supply modes (PSMs) are divided into cable + direct PSM and cable + autotransformer (AT) PSM (including Japanese mode, French mode and new mode). Taking cable + Japanese AT PSM as an example, the scheme of long distance power supply for CTN under the PSMs of co-phase and out-of-phase power supply are designed. On the basis of establishing the equivalent circuit model and the chain circuit model of CTN, taking the train working voltage as the constraint condition, and based on the power flow calculation of multiple train loads, the calculation formula and process for determining the PSD of CTN are given. The impedance and PSD of CTN under the cable + AT PSM are simulated and analyzed, and a certain line is taken as an example to compare the scheme design.Findings: Results show that the equivalent impedance of CTN under the cable + AT PSM is smaller, and the PSD is about 2.5 times of that under the AT PSM, which can effectively increase the PSD and the flexibility of external power supply location.Originality/value: The research content can effectively improve the PSD of traction power supply system and has important reference value for the engineering application of the scheme.
20 November 2025 in International Journal of Electrical Power & Energy Systems