17 November 2022 in Railway Engineering Science
A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit. With the application of two-stage three-phase continuous power supply structure, the electrical characteristics exhibit new features differing from the existing traction system. In this work, the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive. The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses. Based on the chain network model of the traction network, a simulation model is established to analyze the electrical characteristics such as traction current distribution, voltage losses, system equivalent impedance, voltage distribution, voltage unbalance and regenerative energy utilization. In a few words, quite a lot traction current of about 99% is undertaken by long-section cable network. The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure, and the voltage unbalance caused by impedance asymmetry of traction network is less than 1‰. In addition, the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%.
3 December 2024 in IEEE Transactions on Industrial Electronics
Single-phase medium or low voltage distribution networks remain the predominant choice in remote or rural areas, largely due to historical and economic considerations. As economic development progresses, the demand for high-quality three-phase power systems in these regions has increased steadily. To address the challenge of providing three-phase power in remote areas, this article introduces a single-phase to three-phase power flow controller (1PH–3PH PFC) for medium and low voltage distribution networks. The proposed system includes a reverse YNd11 transformer and three half-bridge converters, which have been specifically designed to mitigate grid voltage disturbances, including sags, swells, and harmonics, that may impact loads. Furthermore, the system ensures unit power factor operation while eliminating harmonic currents from the loads. The control strategy incorporates output voltage feedforward and weighted average feedback of the filter inductor current, thereby enhancing system responsiveness. Furthermore, the power flow of apparent and active power under various voltage fluctuation scenarios is analyzed. The proposed scheme is validated through simulation and hardware-in-the-loop experiments. The research results indicate that, in comparison to the UPQC-1Ph–3Ph scheme, the 1PH–3PH PFC solution significantly reduces the converter design capacity, with potential savings of up to 60% of capacity under conditions of a 25% voltage sag.
22 August 2024 in International Journal of Electrical Power & Energy Systems
24 April 2025 in IEEE Transactions on Power Delivery
Railway power conditioner (RPC) is one of the most effective devices in electrified railways for the compensation of negative sequence, reactive power and the utilization of regenerative braking energy. However, the access of RPC will make the railway power supply system exhibit different energy flow modes, which will render the existing principles about wide-band oscillation characteristics opaque (low-frequency oscillation and high-frequency resonance), and increase the difficulty of analysis. The objective of this paper is to present a comprehensive analysis of the wide-band oscillation issue in the RPC-network-train coupling system. Initially, based on the dq decomposition method and mirror-frequency method, a unified impedance model for the system is established considering diverse energy flow modes. Subsequently, the wide-band oscillation distribution is obtained based on the modal decomposition method, thereby revealing the coupling mechanism between the RPC and the existing railway system. The security domain is delineated by further locating the key components affecting the wide-band oscillation based on the sensitivity of the parameters to the frequency and amplitude of the oscillation. Finally, the correctness of the analysis result is verified on the simulation platform and StarSim hardware-in-the-loop experimental platform.