Rejean Fontaine

Prof. Rejean Fontaine

Université de Sherbrooke, Sherbrooke, QC, Canada
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2018 in Instruments
Verified
Journal Article
Open access
PDF file
FNFrédéric Nolet
Frédéric Nolet
SPSamuel Parent
Samuel Parent
NRNicolas Roy
Nicolas Roy
MMMarc-Olivier Mercier
Marc-Olivier Mercier
SCSerge A. Charlebois
Serge A. Charlebois
JPJean-François Pratte
Jean-François Pratte
This paper presents a new quenching circuit (QC) and single photon avalanche diode (SPAD) implemented in TSMC CMOS 65 nm technology. The QC was optimized for single photon timing resolution (SPTR) with a view to an implementation in a 3D digital SiPM. The presented QC has a timing jitter of 4 ps full width at half maximum (FWHM) and the SPAD and QC has a 7.8 ps FWHM SPTR. The QC adjustable threshold allows timing resolution optimization as well as SPAD excess voltage and rise time characterization. The adjustable threshold, hold-off and recharge are essential to optimize the performances of each SPAD. This paper also provides a better understanding of the different contributions to the SPTR. A study of the contribution of the SPAD excess voltage variation combined to the QC time propagation delay variation is presented. The proposed SPAD and QC eliminates the SPAD excess voltage contribution to the SPTR for excess voltage higher than 1 V due to its fixed time propagation delay.

16 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JPJean-François Pratte
Jean-François Pratte
FNFrédéric Nolet
Frédéric Nolet
SPSamuel Parent
Samuel Parent
FVFrédéric Vachon
Frédéric Vachon
NRNicolas Roy
Nicolas Roy
SCSerge A. Charlebois
Serge A. Charlebois
Analog and digital SiPMs have revolutionized the field of radiation instrumentation by replacing both avalanche photodiodes and photomultiplier tubes in many applications. However, multiple applications require greater performance than the current SiPMs are capable of, for example timing resolution for time-of-flight positron emission tomography and time-of-flight computed tomography, and mitigation of the large output capacitance of SiPM array for large-scale time projection chambers for liquid argon and liquid xenon experiments. In this contribution, the case will be made that 3D photon-to-digital converters, also known as 3D digital SiPMs, have a potentially superior performance over analog and 2D digital SiPMs. A review of 3D photon-to-digital converters is presented along with various applications where they can make a difference, such as time-of-flight medical imaging systems and low-background experiments in noble liquids. Finally, a review of the key design choices that must be made to obtain an optimized 3D photon-to-digital converter for radiation instrumentation, more specifically the single-photon avalanche diode array, the CMOS technology, the quenching circuit, the time-to-digital converter, the digital signal processing and the system level integration, are discussed in detail.

21 April 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
JRJulien Rossignol
Julien Rossignol
RTRosana Martinez Turtos
Rosana Martinez Turtos
SGStefan Gundacker
Stefan Gundacker
DGDavid Gaudreault
David Gaudreault
EAEtiennette Auffray
Etiennette Auffray
Rejean FontaineRejean Fontaine
Rejean Fontaine
Computed tomography has greatly improved over the last decade, especially through x-ray dose exposure reduction while maintaining image quality. Herein, a new concept is proposed to improve the contrast-to-noise ratio (CNR) by including the time-of-flight (TOF) information of individual photons to obtain further insight on the photon’s trajectory and to reject scatter contribution. The proof of the concept relies on both simulation and experimental measurements in a cone-beam computed tomography arrangement. Results show a statistical difference between the TOF of scattered and primary photons exploitable in TOF computed tomography. For a large volume of the size of a human abdomen, a scatter reduction from 296% to 4% is achieved in our simulation setup with perfect timing measurements which yields a 110% better CNR, or a dose reduction by a factor of four. Cup artifacts are also reduced from 24.7% to 0.8%, and attenuation inaccuracies are improved from −26.3% to −0.8%. With 100 ps and 10 ps FWHM timing jitters, respectively 75% and 95% of the scatter contribution can be removed with marginal gains below 10 ps. Experimental measurements confirm the feasibility of measuring statistical differences between the TOF of scattered and primary photons.

27 September 2017 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
NRNicolas Roy
Nicolas Roy
FNFrédéric Nolet
Frédéric Nolet
FDFrederik Dubois
Frederik Dubois
MMMarc-Olivier Mercier
Marc-Olivier Mercier
Rejean FontaineRejean Fontaine
Rejean Fontaine
JPJean-Francois Pratte
Jean-Francois Pratte
Time-of-flight measurements are becoming essential to the advancement of several fields, such as preclinical positron emission tomography and high energy physics. Recent developments in single photon avalanche diode (SPAD)-based detectors have spawned a great interest in digital silicon photomultipliers (dSiPMs). To overcome the tradeoff between the photosensitive area and the processing capabilities in current 2-D dSiPM, we propose a novel 3-D digital SiPM, where the SPAD, designed for maximal photosensitive area, will be stacked in 3-D over the electronic circuits, designed in a CMOS node technology. All readout circuits will be implemented directly under the SPAD real estate, including quenching circuit, time-to-digital converter (TDC) and digital readout electronics. This paper focusses on the TDC element of this system, designed in TSMC CMOS 65 nm. This ring oscillator-based Vernier TDC requires only 25 × 50 μm 2 and 160 μW, and achieves 6.9 ps rms timing accuracy.

23 October 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
EGEmilie Gaudin
Emilie Gaudin
MTMaxime Toussaint
Maxime Toussaint
CTChristian Thibaudeau
Christian Thibaudeau
MPMaxime Paille
Maxime Paille
Rejean FontaineRejean Fontaine
Rejean Fontaine
RLRoger Lecomte
Roger Lecomte
The concept of a new ultrahigh resolution (UHR) positron emission tomography (PET) brain scanner featuring truly pixelated detectors based on the LabPET II technology is presented. The aim of this paper is to predict the performance of the scanner using geant4 application for tomographic emission simulations. The NEMA procedures for human and small animal PET scanners were used, whenever appropriate, to simulate spatial resolution, scatter fraction, count rate performance, and the sensitivity of the proposed system compared to state-of-theart PET scanners that would currently be the preferred choices for brain imaging, namely the high-resolution research tomograph dedicated brain PET scanner and the Biograph Vision whole-body clinical PET scanner. The imaging performance was also assessed using the NEMA-NU4 image quality phantom, a mini Hot Spot phantom, and a 3-D voxelized brain phantom. A reconstructed nearly isotropic spatial resolution of 1.3 mm full width at half-maximum is obtained at 10 mm from the center of the field of view. With an energy window of 250-650 keV, the system absolute sensitivity is estimated at 3.4% and its maximum noise equivalent count rate reaches 16.4 kcps at 12 kBq/cc. The simulation results provide evidence of the promising capabilities of the proposed scanner for UHR brain imaging.

14 January 2021 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
WLWilliam Lemaire
William Lemaire
MBMaher Benhouria
Maher Benhouria
KKKonin Koua
Konin Koua
MBMarwan Besrour
Marwan Besrour
LGLouis-Philippe Gauthier
Louis-Philippe Gauthier
Rejean FontaineRejean Fontaine
Rejean Fontaine
Retinal implants aim to partially restore vision to patients suffering from blindness caused by age-related macular degeneration (AMD) or retinitis pigmentosa (RP). Up until now, most prostheses were powered using an inductive link coupled with cables penetrating through the eyeball. Although they efficiently power the implant, they limit long-term reliability and cause postoperative complications. A fully wireless near-infrared power and data link entering the eye through the pupil alleviates these issues but limits the available power and causes energy supply interruptions during blinking. This article presents a retinal implant ASIC architecture optimized for optical operation despite these constraints. It contains 288 individually controlled electrode drivers, each connected to electrode pads with a pitch of 150 μm. A digital controller with a stateless communication scheme allows flexible stimulation sequences and is capable of restoring stimulation within 3 ms after an eye blink. The prototype was fabricated using a CMOS 65-nm low-power technology and occupies an area of 2.8 × 3.1 mm 2 with a static power consumption of 3.1 mW.