Jean-François Pratte

Prof. Jean-François Pratte

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
PLPaul LECOQ
Paul LECOQ
CMChristian Morel
Christian Morel
John PriorJohn Prior
John Prior
DVDimitris Visvikis
Dimitris Visvikis
SGStefan Gundacker
Stefan Gundacker
MBMathieu Benoit
Mathieu Benoit
Since the seventies, positron emission tomography (PET) has become an invaluable medical molecular imaging modality with an unprecedented sensitivity at the picomolar level, especially for cancer diagnosis and the monitoring of its response to therapy. More recently, its combination with x-ray computed tomography (CT) or magnetic resonance (MR) has added high precision anatomic information in fused PET/CT and PET/MR images, thus compensating for the modest intrinsic spatial resolution of PET. Nevertheless, a number of medical challenges call for further improvements in PET sensitivity. These concern in particular new treatment opportunities in the context personalized (also called precision) medicine, such as the need to dynamically track a small number of cells in cancer immunotherapy or stem cells for tissue repair procedures. A better signal-to-noise ratio (SNR) in the image would allow detecting smaller size tumours together with a better staging of the patients, thus increasing the chances of putting cancer in complete remission. Moreover, there is an increasing demand for reducing the radioactive doses injected to the patients without impairing image quality. There are three ways to improve PET scanner sensitivity: improving detector efficiency, increasing geometrical acceptance of the imaging device and pushing the timing performance of the detectors. Currently, some pre-localization of the electron-positron annihilation along a line-of-response (LOR) given by the detection of a pair of annihilation photons is provided by the detection of the time difference between the two photons, also known as the time-of-flight (TOF) difference of the photons, whose accuracy is given by the coincidence time resolution (CTR). A CTR of about 10 picoseconds FWHM will ultimately allow to obtain a direct 3D volume representation of the activity distribution of a positron emitting radiopharmaceutical, at the millimetre level, thus introducing a quantum leap in PET imaging and quantification and fostering more frequent use of 11 C radiopharmaceuticals. The present roadmap article toward the advent of 10 ps TOF-PET addresses the status and current/future challenges along the development of TOF-PET with the objective to reach this mythic 10 ps frontier that will open the door to real-time volume imaging virtually without tomographic inversion. The medical impact and prospects to achieve this technological revolution from the detection and image reconstruction point-of-views, together with a few perspectives beyond the TOF-PET application are discussed.

22 September 2018 in Instruments
Verified
Journal Article
Open access
PDF file
FNFrédéric Nolet
Frédéric Nolet
SPSamuel Parent
Samuel Parent
NRNicolas Roy
Nicolas Roy
MMMarc-Olivier Mercier
Marc-Olivier Mercier
SCSerge A. Charlebois
Serge A. Charlebois
JPJean-François Pratte
Jean-François Pratte
This paper presents a new quenching circuit (QC) and single photon avalanche diode (SPAD) implemented in TSMC CMOS 65 nm technology. The QC was optimized for single photon timing resolution (SPTR) with a view to an implementation in a 3D digital SiPM. The presented QC has a timing jitter of 4 ps full width at half maximum (FWHM) and the SPAD and QC has a 7.8 ps FWHM SPTR. The QC adjustable threshold allows timing resolution optimization as well as SPAD excess voltage and rise time characterization. The adjustable threshold, hold-off and recharge are essential to optimize the performances of each SPAD. This paper also provides a better understanding of the different contributions to the SPTR. A study of the contribution of the SPAD excess voltage variation combined to the QC time propagation delay variation is presented. The proposed SPAD and QC eliminates the SPAD excess voltage contribution to the SPTR for excess voltage higher than 1 V due to its fixed time propagation delay.

16 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JPJean-François Pratte
Jean-François Pratte
FNFrédéric Nolet
Frédéric Nolet
SPSamuel Parent
Samuel Parent
FVFrédéric Vachon
Frédéric Vachon
NRNicolas Roy
Nicolas Roy
SCSerge A. Charlebois
Serge A. Charlebois
Analog and digital SiPMs have revolutionized the field of radiation instrumentation by replacing both avalanche photodiodes and photomultiplier tubes in many applications. However, multiple applications require greater performance than the current SiPMs are capable of, for example timing resolution for time-of-flight positron emission tomography and time-of-flight computed tomography, and mitigation of the large output capacitance of SiPM array for large-scale time projection chambers for liquid argon and liquid xenon experiments. In this contribution, the case will be made that 3D photon-to-digital converters, also known as 3D digital SiPMs, have a potentially superior performance over analog and 2D digital SiPMs. A review of 3D photon-to-digital converters is presented along with various applications where they can make a difference, such as time-of-flight medical imaging systems and low-background experiments in noble liquids. Finally, a review of the key design choices that must be made to obtain an optimized 3D photon-to-digital converter for radiation instrumentation, more specifically the single-photon avalanche diode array, the CMOS technology, the quenching circuit, the time-to-digital converter, the digital signal processing and the system level integration, are discussed in detail.

26 January 2024 in IEEE Journal of the Electron Devices Society
Verified
Journal Article
Open access
SPSamuel Parent
Samuel Parent
FVFrédéric Vachon
Frédéric Vachon
VGValérie Gauthier
Valérie Gauthier
SLSteve Lamoureux
Steve Lamoureux
APAlexandre Paquette
Alexandre Paquette
JPJean-François Pratte
Jean-François Pratte
When developing a technology based on single-photon avalanche diodes (SPADs), the SPAD characterization is mandatory to debug, optimize and monitor the microfabrication process. This is especially true for the development of SPAD arrays 3D integrated with CMOS readout electronics, where SPAD testing is required to qualify the process, independently from the final CMOS readout circuit. This work reports on a characterization and monitoring platform dedicated to SPAD testing at die and wafer level, in the context of a 3D SPAD technology development. The platform relies on a dedicated integrated circuit made in a standard CMOS technology and used in different configurations from a prototype printed circuit board (die-level testing) to active probe cards (wafer-level mapping). The platform gives full access to SPAD characteristics in Geiger mode such as the dark noise, photon detection efficiency and timing resolution. The integrated circuit and its configuration are described in detail as well as results obtained on different SPAD test structures. In particular, the dark count rate mapping demonstrates the benefits of testing SPADs at wafer level at the R&D stage.

25 November 2020 in Measurement Science and Technology
Verified
Journal Article
Closed access
FVFrédéric Vachon
Frédéric Vachon
SPSamuel Parent
Samuel Parent
FNFrédéric Nolet
Frédéric Nolet
HDHenri Dautet
Henri Dautet
JPJean-François Pratte
Jean-François Pratte
SCSerge A. Charlebois
Serge A. Charlebois
The characterization of nuisance parameters in digital silicon photomultipliers (SiPMs) is important to their understanding and future development. Methods able to distinguish the types of events are necessary to obtain fair and legitimate measurements. In this work, the zero photon probability (ZPP) method and the time delay (TD) method are used to measure the dark noise of digital SiPMs free from the contribution of correlated noise such as afterpulsing and crosstalk. It highlights the unique features of digital SiPMs such as the holdoff delay, the digital output signal, and the embedded processing (e.g. the selection of the interval sampling width). The two methods correctly separate the correlated and uncorrelated events in digital SiPMs and therefore the determination of a true photon detection efficiency (PDE) is possible. The ZPP method is also implemented inside a digital SiPM using embedded digital signal processing.

1 September 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
Tommy RossignolTommy Rossignol
Tommy Rossignol
NRN. Roy
N. Roy
SPS. Parent
S. Parent
KDKeven Deslandes
Keven Deslandes
FNFrédéric Nolet
Frédéric Nolet
JPJean-François Pratte
Jean-François Pratte
A new trend in large area noble liquid experiments is to measure the scintillation light with photodetectors and their electronics inside the active volume. Compared to the typical approach of using silicon photomultipliers (SiPM) with an analog readout chain leading to an analog-to-digital converter, this paper presents a new 3D photon-to-digital converter (PDC) readout that takes advantage of the binary nature of the single-photon avalanche diodes (SPAD). The readout contains 4096 pixels over 25 mm2, each including a 3D bonding pad and a quenching circuit. The readout features three different outputs: a fast flag to get the timestamp of each event from an external time-to-digital converter, a digital sum to retrieve the number of pixels triggered during an event, and an analog monitor to generate an analog SiPM-like output. The analog monitor is also used to validate the two former digital outputs. The readout also includes 61 2D CMOS SPADs for validation purpose prior to the final 3D integration with SPADs custom made according to our design by Teledyne DALSA (Bromont, Canada). As a first system integration toward large-area detector applications, a mini-tile of 2 × 2 readouts has been developed to test all the functionalities. The measured single-photon timing resolution ranges from 72 to 93 ps FWHM across the mini-tile SPAD channels population (i.e. 4 × 61 channels). The flag timing resolution is below 95 ps RMS, which includes the contribution of the optimized flag H-tree but also an additional trigger tree that replaces the 3D SPAD array at this stage of development. Once bonded with the 3D SPADs, the trigger tree won't be required to measure the flag timing resolution. With the removed contribution of the trigger tree, the estimated flag timing resolution should be below 45 ps RMS. The extent of the benefits of the digital sum output depend on the application, and this paper focuses on two cases. First, a low-power coincidence scheme such as required by the nEXO liquid xenon experiment, leading to a power consumption as low as 140 μW per PDC. With a finer sampling of the scintillation light such as required for pulse shape discrimination in liquid argon, the power consumption remains below 100 μW per PDC. Overall, this readout is designed as a replacement for a typical analog SiPM chain, without compromise on the performances.