Simone Secchi

Prof. Simone Secchi

Department of Architecture, University of Florence
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Journal of Building Engineering
Verified
Journal Article
Closed access
Simone SecchiSimone Secchi
Simone Secchi
Francesco AsdrubaliFrancesco Asdrubali
Francesco Asdrubali
GCGianfranco Cellai
Gianfranco Cellai
ENElisa Nannipieri
Elisa Nannipieri
ARAntonella Rotili
Antonella Rotili
IVIrene Vannucchi
Irene Vannucchi

1 November 2017 in Applied Acoustics
Verified
Journal Article
Closed access
Simone SecchiSimone Secchi
Simone Secchi
Arianna AstolfiArianna Astolfi
Arianna Astolfi
GCGiulia Calosso
Giulia Calosso
DCDavid Casini
David Casini
GCGianfranco Cellai
Gianfranco Cellai
Louena ShtrepiLouena Shtrepi
Louena Shtrepi

7 December 2015 in Buildings
Verified
Journal Article
Open access
PDF file
NMNicolò Zuccherini Martello
Nicolò Zuccherini Martello
Patrizio FaustiPatrizio Fausti
Patrizio Fausti
ASAndrea Santoni
Andrea Santoni
Simone SecchiSimone Secchi
Simone Secchi
The problem of solar irradiation in building façades with large windows is often solved with the use of external shading devices, such as brise-soleil systems, but their potential acoustic effects on building façades are usually neglected. The purpose of this work is a preliminary consideration of the acoustic behaviour of brise-soleil systems and, furthermore, the evaluation of the possibility to improve their performances, in terms of Sound Pressure Level (SPL) abatement over glass surfaces. The paper reports the results of a study on two portions of the same office building, with shading devices installed in front of large windows. Both airborne sound insulation measurements and SPL measurements over the glass surfaces of the windows were carried out to compare different situations, with or without louvers, and with sound absorbing experimental louvers as well. Results show that the louvers' presence can produce an increase in the SPL over the glass surface as a consequence of the reflection of the sound. Results further show that sound absorbing louvers improve the noise protection of the system, in terms of the SPL reduction, over glass surfaces, cancelling out the negative effect of the standard shading devices.

14 November 2018 in Buildings
Verified
Journal Article
Open access
PDF file
SMSara Delle Macchie
Sara Delle Macchie
Simone SecchiSimone Secchi
Simone Secchi
GCGianfranco Cellai
Gianfranco Cellai
This paper reports the acoustic issues of open plan office environments. According to a detailed research based on the scientific literature of the most suitable acoustic descriptors recommended for the open plan offices analysis, the main typological-functional configurations of these environments have been analyzed in order to identify six spatial typologies. The variation of acoustic parameters of these typologies has been evaluated by using a sound pyramid tracing software. The analysis procedure was calibrated in a case study of an office environment, where a measurement campaign was carried out. Results point out that the acoustic improvement of open plan offices can usually be achieved by introducing a sound absorbing false ceiling and dividing panels between working positions, but there are different issues depending on spatial geometries of the office. Better results are referred to office typologies characterized by reduced height and equal plan dimensions.

1 November 2015 in Energy Procedia
Verified
Journal Article
Open access
Simone SecchiSimone Secchi
Simone Secchi
Fabio SciurpiFabio Sciurpi
Fabio Sciurpi
LPLeone Pierangioli
Leone Pierangioli
MRMatteo Randazzo
Matteo Randazzo
The typical orientation of the facades of school buildings, along with the presence of large windows and permanent position of the students, can create uncomfortable environmental conditions caused by eye strain due to glare and local thermal discomfort due to asymmetrical thermal radiation. In this work, the effectiveness of various types of high performance glazing and external shading is evaluated, by means of simulations of visual comfort and energy efficiency. Simulations were carried out for a case study which is representative of a typical classroom of a school, located in a town of Tuscany, where instrumental monitoring of existing thermal and lighting conditions was conducted. The case study was selected through an analysis of energy consumption of the whole school building stock of the city, over a period of five years. The analysis has allowed to select the most critical one in terms of energy consumption and the most representative one regarding the Italian school building stock. The selected building has been analyzed by means of building performance simulation software. A survey about the school users’ perception of comfort levels was also carried out by means of questionnaires

28 July 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Simone SecchiSimone Secchi
Simone Secchi
Nicoletta SetolaNicoletta Setola
Nicoletta Setola
Luca MarziLuca Marzi
Luca Marzi
VAVeronica Amodeo
Veronica Amodeo
Hospitals include a variety of different spaces with different requirements and levels of sensitivity to noise but also different activities and equipment that can cause high noise levels. In this article, noise disturbance in hospitals is studied with reference to a case study in a maternity ward. The analysis is carried out by means of sound insulation measurements between bedrooms and between bedroom and corridor. Equivalent sound pressure level measurements were carried out continuously for two days and nights. The number of awakening events is examined for each hour of the two nights. In addition, the results of a questionnaire conducted on more than 100 patients are reported. The results of the study show that the main cause of noise disturbance is activity in the corridors and that this kind of disturbance is usually repeated throughout the night. This is made more critical by the poor acoustic performance of the doors, but also by the habit of keeping doors open or half-open to allow doctors to always control patients. The article proposes some possible solutions to reduce noise intrusion from the corridor to the rooms.