Yesica Vicente-Martińez

Dr. Yesica Vicente-Martińez

Spanish Air Force Academy, University Centre of Defense, Coronel López Peña n/n, 30720 Murcia, Spain
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 November 2014 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
ILIgnacio López-García
Ignacio López-García
YVYesica Vicente-Martińez
Yesica Vicente-Martińez
MHManuel Hernandez-Cordoba
Manuel Hernandez-Cordoba

1 October 2013 in Talanta
Verified
Journal Article
Closed access
ILIgnacio López-García
Ignacio López-García
MBMarisol Briceño
Marisol Briceño
YVYesica Vicente-Martińez
Yesica Vicente-Martińez
MHManuel Hernandez-Cordoba
Manuel Hernandez-Cordoba


1 January 2012 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
ILIgnacio López-García
Ignacio López-García
YVYesica Vicente-Martińez
Yesica Vicente-Martińez
MHManuel Hernandez-Cordoba
Manuel Hernandez-Cordoba
A new procedure for the determination of very low levels of Cr(III) and Cr(VI) using ionic liquid dispersive liquid–liquid microextraction (IL-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS) is presented. The ionic liquid, 1-octyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([C8MIm][NTf2]), is formed in situ by mixing 1-octyl-3-methylimidazolium chloride ([C8MIm]Cl) and lithium bis(trifluoromethanesulfonyl)imide ([NTf2]Li) aqueous solutions, and is used to extract complexes originating from Cr(III) and Cr(VI) with ammonium pyrrolidinedithiocarbamate (APDC). No organic solvents are required, the dispersion being due to the very fine droplets of ([C8MIm][NTf2]) originated in the aqueous solution. After centrifugation, the concentration of chromium in the sedimented phase is determined by ETAAS. The total content of chromium is measured using 0.01 mol L−1 APDC at pH = 1. In the presence of 0.001 mol L−1 ethylenediaminetetraacetate, Cr(III) is not extracted, and the analytical signal corresponds to Cr(VI). The level of Cr(III) is obtained by difference. The enrichment factor of the procedure is 300 and a detection limit of 2 ng L−1 is achieved. The relative standard deviation for 10 replicates at the 0.05 μg L−1 level is close to 8%. The recoveries of spiked samples are in the 95–104% range. The method is applied to the analysis of water samples as well as lixiviates obtained from toys made of plastic materials.

1 March 2020 in Science of The Total Environment
Verified
Journal Article
Closed access
YVYesica Vicente-Martińez
Yesica Vicente-Martińez
MCM. Caravaca
M. Caravaca
ASA. Soto-Meca
A. Soto-Meca
OOOscar de Francisco Ortiz
Oscar de Francisco Ortiz
FGF. Gimeno
F. Gimeno