Jung-Shun Chen

Dr. Jung-Shun Chen


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
JCJung-Shun Chen
Jung-Shun Chen
The indoor air of a hospital is always full of bacteria and viruses due to patients with different diseases. These bacteria and viruses could be highly infectious to the people in the hospital irrespective of their health conditions, and could be hazardous to the patients, their care takers, and hospital staff. Thus, keeping a good hospital air quality is very essential to the operation of the hospital. This study aims at enhancing ventilation of the interior lighting of hospitals with germicidal capabilities. Air disinfection is accomplished by adding the specially designed disinfecting filters and fans to existing embedded lamps in the hospitals. The embedded lamp has a square shape of 601 mm in width and 112 mm in thickness. In the design stage, the air flow inside the embedded lamp with the added filters and fans was investigated by numerical simulation using a computational fluid dynamics (CFD) tool. Three designs, referred to as Types 1, 2, and 3, were evaluated using steady-state CFD flow simulations. The ventilation rate of the Type 1 design was about 251.9 CMH, and 348.3 CMH for the Type 2 design by increasing the fan outlet area. However, even though the ventilation was increased by 34%, the flow field of the Type 2 design was not uniform, resulting in flows being circulated around the side locations. Thus, the Type 3 design further treats this aspect by streamlining the outlet geometry and adding flow guiding vanes to reduce flow resistance and flow unsteadiness; the corresponding air ventilation rate reached 376.3 CMH. Hence, the Type 3 design was fabricated and tested. The test results confirm that the design not only has a higher ventilation rate but also operates under a smaller pressure drop, thus accomplishing the goal of providing good air quality in the hospital environment efficiently. Moreover, the associated flow noise is reduced by about 8 dBA. Hence, both an increase in the air ventilation rate and a reduction of noise are achieved simultaneously by the present method.

15 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Fu Ming TzuFu Ming Tzu
Fu Ming Tzu
JCJung-Shun Chen
Jung-Shun Chen
SHShih-Hsien Hsu
Shih-Hsien Hsu
In this study, we developed a high-resolution, more accurate, non-destructive apparatus for refining the detection of electrode pixels in a thin-film-transistor liquid-crystal display (TFT-LCD). The hybrid optoelectronic apparatus simultaneously uses an array tester linked with the automatic optical inspection of panel defects. Unfortunately, due to a tiny air gap in the electro-optical inspector, the situation repeatedly causes numerous scratches and damages to the modulator; therefore, developing alternative equipment is necessary. Typically, in TFT-LCDs, there are open, short, and cross short electrical defects. The experiment utilized a multiple-line scan with the time delay integration (TDI) of a charge-coupled device (CCD) to capture a sharp image, even under low light, various speeds, or extreme conditions. In addition, we explored the experimental efficacy of detecting the electrode pixel of the samples and evaluated the effectiveness of a 7-inch opaque quartz mask. The results show that an array tester and AOI can detect a TFT-LCD electrode pixel sufficiently; therefore, we recommend adopting the hybrid apparatus in the TFT-LCD industry.

8 January 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Fu Ming TzuFu Ming Tzu
Fu Ming Tzu
SHShih-Hsien Hsu
Shih-Hsien Hsu
JCJung-Shun Chen
Jung-Shun Chen
This paper describes the non-contact optical detection of debris material that adheres to the substrates of color filters (CFs) and thin-film transistors (TFTs) by area charge-coupled devices (CCDs) and laser sensors. One of the optical detections is a side-view illumination by an area CCD that emits a coherency light to detect debris on the CF. In contrast to the height of the debris material, the image is acquired by transforming the geometric shape from a square to a circle. As a result, the side-view illumination from the area CCD identified the height of the debris adhered to the black matrix (BM) as well as the red, green, and blue of a CF with 95, 97, 98, and 99% accuracy compared to the golden sample. The uncertainty analysis was at 5% for the BM, 3% for the red, 2% for the green, and 1% for the blue. The other optical detection, a laser optical interception with a horizontal alignment, inspected the material foreign to the TFT. At the same time, laser sensors intercepted the debris on the TFT at a voltage of 3.5 V, which the five sets of laser optics make scanning the sample. Consequently, the scanning rate reached over 98% accuracy, and the uncertainty analysis was within 5%. Thus, both non-contact optical methods can detect debris at a 50 μm height or lower. The experiment presents a successful design for the efficient prevention of a valuable component malfunction.

25 November 2018 in Crystals
Verified
Journal Article
Open access
PDF file
Fu Ming TzuFu Ming Tzu
Fu Ming Tzu
JCJung-Shun Chen
Jung-Shun Chen
JCJung-Hua Chou
Jung-Hua Chou
Protrusive defects on the color filter of thin-film transistor (TFT) liquid crystal displays (LCDs) frequently damage the valuable photomask. A fast method using side-view illuminations with digital charge-coupled devices (CCDs) that filter out ultraviolet (UV)490 nm was developed to detect the protrusive defects of thin-film type in four substrates of the black matrix (BM), red, green, and blue color filters. Between the photomask and substrate, the depth of field (DOF) is normally 300 μm for the proximity-type aligner; we select the four substrates to evaluate the detectability in the task. The experiment is capable of detecting measurements of 300 μm, and measurements even lower than 100 μm can be assessed successfully. The maximum error of the measurement is within 6% among the four samples. Furthermore, the uncertainty analysis of three standard deviations is conducted. Thus, the method is cost-effective to prevent damage for valuable photomasks in the flat-panel display industry.

19 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JCJung-Shun Chen
Jung-Shun Chen
SCShou-Yen Chao
Shou-Yen Chao
CCChing-Che Chen
Ching-Che Chen
With the rapid progress in data mining, deep learning, and artificial intelligence, the demand for datacenters of various sizes increases globally. Datacenters typically require an environment with properly controlled temperature and humidity conditions for their proper operations. These needed environmental conditions are always provided by an air conditioning system. In humid and hot regions, both energy consumption and the splash of water condensate in using the fin-and-tube heat exchangers are of concern because reliability issues can occur. In this study, the effects of fin surface hydrophilic/hydrophobic coatings on the performance of the fin-and-tube heat exchangers, including the heat transfer rate, pressure drop, and water-condensate splash, were investigated experimentally. By varying the cooling air speeds and fin pitches, the results show that hydrophilic surface coating is an effective method in reducing both the pressure drop (thus saving energy) and the condensate splash, while not affecting the heat transfer rates significantly. The water splash reduction is achieved by both the increased air speed for splashing and a smaller amount of splashing. Water splash can even be completely eliminated if the airspeed was below about 3 m/s. In contrast, hydrophobic surface coating will increase both pressure drop and water splash; thus, should be applied with caution.

14 April 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Fu Ming TzuFu Ming Tzu
Fu Ming Tzu
JCJung-Shun Chen
Jung-Shun Chen
SHShih-Hsien Hsu
Shih-Hsien Hsu
This paper explores the effectiveness of the white, red, green, and blue light emitted diodes (LEDs) light sources to detect the third layer of the electrode pixel and the fourth layer of the via-hole passivation on thin-film transistors. The time-delay-integration charge-coupled device and a reflective spectrometer were implemented in this experiment. The optical conditions are the same, as each light source and the digital image’s binary method also recognize the sharpness and contrast in the task. Consequently, the white and the blue LED light sources can be candidates for the light source for the optical inspection, especially for monochromic blue LED’s outperformance among the light sources. The blue LED demonstrates the high spatial resolution and short wavelength’s greater energy to trigger the photosensor. Additionally, the metal material has shown a tremendous responsibility in the photosensor with 150 Dn/nj/cm2 over the sensibility. The mercury 198Hg-pencil discharge lamp emits the stable spectral wavelength to significantly calibrate the spectrometer’s measurement.